HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: NO
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO

Health Hazards Acute And Chronic: ACUTE:MAY BE HARMFUL BY INHALATION, INGESTION OR SKIN ABSORPTION. MAY CAUSE IRRITATION.

Explanation of Carcinogenicity: NOT RELEVANT

Signs and Symptoms of Overexposure: SEE HEALTH HAZARDS.

Medical Conditions Aggravated by Overexposure: NONE SPECIFIED BY MANUFACTURER.

==============================================================================
FIRST AID
==============================================================================
EYE:IMMEDIATELY FLUSH W/COPIOUS AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. SKIN:IMMEDIATELY WASH W/SOAP & COPIOUS AMOUNTS OF WATER. WASH CONTAMINATED CLOTHING BEFORE REUSE. INHAL:REMOVE TO FRESH AIR. IF NOT BREATHING GIVE ARTFICIAL RESPIRATI ON. IF BREATHING IS DIFFICULT, GIVE OXYGEN. INGEST:WASH OUT MOUTH W/WATER PROVIDED PERSON IS CONSCIOUS. CALL MD.

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: N/K

Auto Ignition Temperature Text: 

Lower Limits: N/K Upper Limits: N/K

Extinguishing Media: WATER SPRAY, CARBON DIOXIDE, DRY CHEMICAL POWDER OR APPROPRIATE FOAM.

Fire Fighting Procedures: WEAR NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE EQUIPMENT (FP N).

Unusal Fire/Explosion Hazard: EMITS TOXIC FUMES UNDER FIRE CONDITIONS.

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: WEAR NIOSH/MSHA APPROVED SCBA, RUBBER BOOTS & HEAVY RUBBER GLOVES. SWEEP UP, PLACE IN A BAG & HOLD FOR WASTE DISPOSAL. AVOID RAISING DUST. VENTILATE AREA & WASH SPILL SITE AFTER MATERIAL PICKUP IS COMPLETE.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.

Waste Disposal Methods: DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL REGULATIONS (FP N). DISSOLVE OR MIX MATERIAL W/COMBUSTIBLE SOLVENT & BURN IN A CHEMICAL INCINERATOR EQUIPPED W/AFTERBURNER & SCRUBBER.

==============================================================================
HANDLING AND STORAGE
==============================================================================
AVOID CONTACT & INHALATION. DO NOT GET IN EYES, ON SKIN, ON CLOTHING. HARMFUL SOLID. KEEP TIGHTLY CLOSED. STORE IN A COOL DRY PLACE.

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: NIOSH/MSHA APPROVED RESPIRATOR.
Ventilation: MECHANICAL EXHAUST REQUIRED.
Protective Gloves: RUBBER GLOVES.
Eye Protection: CHEMICAL WORKERS GOGGLES (FP N).
Other Equipment: SAFETY SHOWER & EYE BATH. WEAR SUITABLE PROTECTIVE CLOTHING.
Work Hygenic Practices: SAFETY SHOWER & EYE BATH. WEAR SUITABLE PROTECTIVE CLOTHING.
Supplemental Safety & Health: NONE SPECIFIED BY MANUFACTURER.

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
Boiling Point: 
N/K
Melting/Freezing Point: 
>280F,>138C
Decomposition Temp: 
N/K
Vapor Pressure: N/K Vapor Density: N/K
Specific Gravity: N/K
PH: N/K
Viscosity: N/P
Evaporation Rate & Reference: N/K
Solubility in Water: N/K
Appearance and Odor: WHITE CRYSTALLINE POWDER.
Percent Volatiles by Volume: N/K
Corrosion Rate: N/K

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: NONE SPECIFIED BY MANUFACTURER.
Materials to Avoid: STRONG OXIDIZING AGENTS, STRONG ACIDS, STRONG BASES.
Hazardous Decomposition Products: TOXIC FUMES OF:CARBON MONOXIDE, CARBON DIOXIDE, NITROGEN OXIDES, SULFUR OXIDES.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: NOT RELEVANT

==============================================================================
TOXICOLOGICAL
==============================================================================
N/P

==============================================================================
ECOLOGICAL
==============================================================================
N/P

==============================================================================
DISPOSAL
==============================================================================
DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL REGULATIONS (FP N). DISSOLVE OR MIX MATERIAL W/COMBUSTIBLE SOLVENT & BURN IN A CHEMICAL INCINERATOR EQUIPPED W/AFTERBURNER & SCRUBBER.

==============================================================================
TRANSPORTATION
==============================================================================
N/P

==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media