HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: YES
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO

Health Hazards Acute And Chronic: ACUTE:MAY BE HARMFUL BY INHALATION, INGESTION OR SKIN ABSORPTION. MAY CAUSE IRRITATION.

Explanation of Carcinogenicity: NONE SPECIFIED BY MANUFACTURER.

Signs and Symptoms of Overexposure: NONE SPECIFIED BY MANUFACTURER.

Medical Conditions Aggravated by Overexposure: NONE SPECIFIED BY MANUFACTURER.

==============================================================================
FIRST AID
==============================================================================
INGEST:WASH OUT MOUTH W/WATER PROVIDED PERSON IS CONSCIOUS. CALL MD. SKIN:FLUSH W/COPIOUS AMTS OF WATER FOR AT LEAST 15 MIN. REMOVE CONTAMD CLTHG/SHOES. CALL MD. INHAL:REMOVE TO FRESH AIR. IF BRTHG BECOMES DIFFICULT, CALL MD. EYES:FLUSH W/C OPIOUS AMTS OF WATER FOR AT LEAST 15 MIN. ASSURE ADEQ FLUSHING BY SEPARATING LIDS W/FINGERS. CALL MD.

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: N/K

Auto Ignition Temperature Text: 

Lower Limits: N/K Upper Limits: N/K

Extinguishing Media: CARBON DIOXIDE, DRY CHEMICAL POWDER, ALCOHOL OR POLYMER FOAM.

Fire Fighting Procedures: WEAR NIOSH/MSHA APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT (FP N). PREVENT CONTACT WITH SKIN AND EYES.

Unusal Fire/Explosion Hazard: EMITS TOXIC FUMES UNDER FIRE CONDITIONS.

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: WEAR NIOSH/MSHA APPROVED PROTECTIVE EQUIPMENT. SWEEP UP, PLACE IN BAG & HOLD FOR WASTE DISPOSAL. AVOID RAISING DUST. VENTILATE AREA & WASH SPILL SITE AFTER MATERIAL PICKUP IS COMPLETE.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.

Waste Disposal Methods: DISSOLVE OR MIX MATERIAL W/COMBUSTIBLE SOLVENT & BURN IN CHEMICAL INCINERATOR EQUIPPED W/AFTERBURNER & SCRUBBER. OBSERVE ALL FEDERAL, STATE AND LOCAL LAWS.

==============================================================================
HANDLING AND STORAGE
==============================================================================
CAUTION:AVOID CONTACT AND INHALATION.

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: WEAR APPROPRIATE NIOSH/MSHA APPROVED RESPIRATOR.
Ventilation: MECHANICAL EXHAUST REQUIRED.
Protective Gloves: CHEMICAL RESISTANT GLOVES.
Eye Protection: CHEMICAL WORKERS GOGGLES (FP N).
Other Equipment: PROTECTIVE CLOTHING.
Work Hygenic Practices: PROTECTIVE CLOTHING.
Supplemental Safety & Health: NONE SPECIFIED BY MANUFACTURER.

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
HCC: N1
Boiling Point: 
N/K
Melting/Freezing Point: 
N/K
Decomposition Temp: 
N/K
Vapor Pressure: N/K Vapor Density: N/K
Specific Gravity: N/K
PH: N/K
Viscosity: N/P
Evaporation Rate & Reference: N/K
Solubility in Water: N/K
Appearance and Odor: SOLID.
Percent Volatiles by Volume: N/K
Corrosion Rate: N/K

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: NONE SPECIFIED BY MANUFACTURER.
Materials to Avoid: NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products: TOXIC FUMES OF:CO, CO*2, NO*X, SO*X.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: NOT RELEVANT

==============================================================================
TOXICOLOGICAL
==============================================================================
N/P

==============================================================================
ECOLOGICAL
==============================================================================
N/P

==============================================================================
DISPOSAL
==============================================================================
DISSOLVE OR MIX MATERIAL W/COMBUSTIBLE SOLVENT & BURN IN CHEMICAL INCINERATOR EQUIPPED W/AFTERBURNER & SCRUBBER. OBSERVE ALL FEDERAL, STATE AND LOCAL LAWS.

==============================================================================
TRANSPORTATION
==============================================================================
N/P

==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media