CAS
# 109-99-9 TETRAHYDROFURAN for HPLC
|
|
Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad
- 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300
Fax
: + 91 129 4190333
E-mail: bluluxlab@gmail.com Website
: www.blulux.com
|
|

|
HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: YES
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO
Health Hazards Acute And Chronic: ACUTE: MAY BE HARMFUL BY INHALATION,
INGESTION OR SKIN ABSORPTION. VAPOR OR MIST IS IRRITATING TO EYES, MUCOUS
MEMBRANES & UPPER RESPIRATORY TRACT. CAUSES SKIN IRRITATION. EXPOSURE CAN
CAUSE COUGHING, CHEST PAINS, DIFFICULTY IN BREATHING, N AUSEA, DIZZINESS &
HEADACHE.
Explanation of Carcinogenicity: NOT RELEVANT.
Signs and Symptoms of Overexposure: SEE HEALTH HAZARDS.
Medical Conditions Aggravated by Overexposure: NONE SPECIFIED BY MANUFACTURER.
==============================================================================
FIRST AID
==============================================================================
EYES/SKIN:FLUSH EYES/SKIN W/COPIOUS AMOUNTS OF WATER FOR AT LEAST 15 MINS WHILE
REMOVING CONTAMINATED CLOTHING & SHOES. WASH CONTAMINATED CLOTHING BEFORE
REUSE. INHAL:REMOVE TO FRESH AIR. IF NOT BREATHING, GIVE ARTIFICIAL
RESPIRATION. IF BR EATHING IS DIFFICULT, GIVE OXGEN. CALL MD.
==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: 1F,-17C
Auto Ignition Temperature Text:
Lower Limits: 1.8% Upper Limits: 11.8%
Extinguishing Media: CARBON DIOXIDE, DRY CHEM PWDR, ALCOHOL OR POLYMER FOAM.
WATER MAY BE EFTIVE FOR COOLING, BUT MAY NOT EFT EXTINGUISHMENT.
Fire Fighting Procedures: WEAR NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT (FP N). USE WATER SPRAY TO COOL FIRE-EXPOSED CONTAINERS.
Unusal Fire/Explosion Hazard: EXTREMELY FLAMM. VAP MAY TRAVEL CONSIDERABLE
DISTANCE TO SOURCE OF IGNIT & FLASH BACK. CONTR EXPLOS MAY OCCUR UNDER FIRE
CNDTNS. ON EXPOS TO AIR, (SUPP DATA)
==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: EVAC AREA. SHUT OFF ALL SOURCES OF IGNIT. WEAR
NIOSH/MSHA APPRVD SCBA, RUB BOOTS & HEAVY RUB GLOVES. COVER W/AN ACTIVATED
CARBON ABSORB, TAKE UP & PLACE IN CLSD CONTRS. TRANSPORT OUTDOORS. VENT
AREA & WASH SPILL SITE AFTER MATL PICKUP IS CO MPLETE.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: BURN IN A CHEMICAL INCINERATOR EQUIPPED W/AN
AFTERBURNER & SCRUBBER BUT EXERT EXTRA CARE IN IGNITING AS THIS MATERIAL IS
HIGHLY FLAMMABLE. OBSERVE ALL FEDERAL, STATE & LOCAL LAWS.
==============================================================================
HANDLING AND STORAGE
==============================================================================
HYGROSCOPIC. STORE IN A COOL, DRY PLACE. STORE UNDER NITROGEN. KEEP AWAY FROM
HEAT, SPARKS & OPEN FLAME. KEEP TIGHTLY CLOSED. IRRITANT.
==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: WEAR APPROPRIATE NIOSH/MSHA APPROVED RESPIRATOR.
Ventilation: MECHANICAL EXHAUST REQUIRED.
Protective Gloves: CHEMICAL-RESISTANT GLOVES.
Eye Protection: CHEMICAL WORKERS GOGGLES (FP N).
Other Equipment: OTHER PROTECTIVE CLOTHING, SAFETY SHOWER & EYE BATH.
Work Hygenic Practices: OTHER PROTECTIVE CLOTHING, SAFETY SHOWER & EYE
BATH.
Supplemental Safety & Health: MFRS TRADE NAME/PART NO:INHIBITOR-FREE,
27038-5. VP:129 @ 20C; 114 @ 15C. EXPLO HAZ:TETRAHYDROFURAN FORMS PEROXIDES
WHICH CAN EXPLODE UPON CONTACT W/STRONG BASE OR METAL HYDRIDES WHEN THE
PEROXIDE CONCENTRATION IS GREATER THAN 0.5%.
==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
HCC: F3
Boiling Point:
153F,67C
Melting/Freezing Point:
-162F,-108C
Decomposition Temp:
N/K
Vapor Pressure: SUPP DATA Vapor Density: 2.5
Specific Gravity: 0.886
PH: N/K
Viscosity: N/P
Evaporation Rate & Reference: N/K
Solubility in Water: N/K
Appearance and Odor: COLORLESS LIQUID.
Percent Volatiles by Volume: N/K
Corrosion Rate: N/K
==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: NONE SPECIFIED BY MANUFACTURER.
Materials to Avoid: ACIDS, BASES, OXIDIZING AGENTS & OXYGEN.
Hazardous Decomposition Products: TOXIC FUMES OF CARBON MONOXIDE & CARBON
DIOXIDE.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: NOT RELEVANT.
==============================================================================
TOXICOLOGICAL
==============================================================================
N/P
==============================================================================
ECOLOGICAL
==============================================================================
N/P
==============================================================================
DISPOSAL
==============================================================================
BURN IN A CHEMICAL INCINERATOR EQUIPPED W/AN AFTERBURNER & SCRUBBER BUT
EXERT EXTRA CARE IN IGNITING AS THIS MATERIAL IS HIGHLY FLAMMABLE. OBSERVE ALL
FEDERAL, STATE & LOCAL LAWS.
==============================================================================
TRANSPORTATION
==============================================================================
N/P
==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================
|
|
|
Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical
Reagents & Dehydrated Culture Media
|
|
|
|

|
|