CAS
# 7772-99-8 STANNOUS CHLORIDE
|
|
Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad
- 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300
Fax
: + 91 129 4190333
E-mail: bluluxlab@gmail.com Website
: www.blulux.com
|
|

|
HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: YES
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO
Health Hazards Acute And Chronic: ACUTE: INHALATION CAN CAUSE COUGHING,
CHOKING, & INFLAMATION OF THE RESPIRATORY TRACT. SWALLOWING CAN CAUSE BURNS
TO MOUTH & G.I. TRACT. EYE CONTACT CAN CAUSE SEVERE BURNS & DAMAGE.
SKIN CONTACT CAN CAUSE SEVERE BURNS AND DEEP ULCERS & DISC OLOR SKIN.
CHRONIC: CONCENTRATED VAPORS MAY CAUSE EROSION OF TEETH.
Explanation of Carcinogenicity: HYDROCHLORIC ACID IS NOT LISTED BY IARC, NTP,
OR OSHA AS A CARCINOGEN.
Signs and Symptoms of Overexposure: INFLAMMATION OF THE NOSE, THROAT, UPPER
RESPIRATORY TRACT, EYES, SKIN AND MUCOUS MEMBRANES. VERY CORROSIVE AND CAN
CAUSE SEVERE BURNS AND DAMAGE. LONG TERM EXPOSURES SELDOM OCCUR DUE TO THE
CORROSIVE PROPERTIES OF THE ACID.
Medical Conditions Aggravated by Overexposure: PERSONS WITH A HISTORY OF
AILMENTS OR WITH A PRE-EXISTING DISEASE INVOLVING THE EYES, SKIN, OR
RESPIRATORY TRACT MAY BE AT INCREASED RISK FROM EXPOSURE.
==============================================================================
FIRST AID
==============================================================================
INHALATION:REMOVE TO FRESH AIR. RESUSCITATE IF NOT BREATHING. GET MEDICAL
ATTENTION. EYES:IMMEDIATELY FLUSH WITH PLENTY OF WATER FOR 15 MINUTES HOLDING
EYELIDS OPEN. GET IMMEDIATE MEDICAL ATTENTION. SKIN:REMOVE CONTAMINATED
CLOTHING. WASH W ITH SOAP AND WATER. GET IMMEDIATE MEDICAL ATTENTION.
INGESTION:DO NOT INDUCE VOMITING. GIVE NOTHING BY MOUTH IF UNCONSCIOUS. GET
IMMEDIATE MEDICAL ATTENTION.
==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: NONE
Auto Ignition Temperature Text:
Lower Limits: N/R Upper Limits: N/R
Extinguishing Media: USE WATER FOG, CARBON DIOXIDE, FOAM, OR DRY CHEMICAL.
Fire Fighting Procedures: WEAR FIRE FIGHTING PROTECTIVE EQUIPMENT AND A FULL
FACED SELF CONTAINED BREATHING APPARATUS. EVACUATE AREA. COOL FIRE EXPOSED
CONTAINERS WITH WATER SPRAY.
Unusal Fire/Explosion Hazard: COMBUSTION OR HEAT OF FIRE MAY PRODUCE HAZARDOUS
DECOMPOSITION PRODUCTS AND VAPORS.
==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: SMALL SPILL: FLUSH WITH WATER AND NEUTRALIZE WITH
ALKALINE MATERIAL. SEWER NEUTRALIZED MATERIAL WITH EXCESS WATER. LARGE SPILL:
EVACUATE AND VENTILATE AREA. IF POSSIBLE, STOP LEAK. DIKE TO RETAIN RUN OFF.
NEUTRALIZE & PICK UP WITH ABSORBENT MATERIAL.
Neutralizing Agent: SODA ASH, LIME OR OTHER SUITABLE ALKALINE MATERIAL.
Waste Disposal Methods: DISPOSAL SHOULD BE MADE IN ACCORDANCE WITH ALL
APPLICABLE FEDERAL, STATE AND LOCAL LAWS AND REGULATIONS. DISPOSE IN A
RCRA-APPROVED WASTE FACILITY OR SEWER THE NEUTRALIZED SLURRY WITH EXCESS WATER
IF LOCAL ORDINANCES ALLOW.
==============================================================================
HANDLING AND STORAGE
==============================================================================
STORE IN A COOL, DRY, WELL VENTILATED AREA. KEEP CONTAINERS TIGHTLY CLOSED WHEN
NOT IN USE. PROTECT CONTAINERS FROM PHYSICAL DAMAGE & DIRECT SUNLIGHT.
==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: IF VENTILATION DOES NOT MAINTAIN INHALATION EXPOSURES
BELOW PEL(TLV), USE NIOSH/MSHA APPROVED FULL FACEPIECE CHEMICAL CARTRIDGE
RESPIRATOR OR A SUPPLIED AIR FULL FACEPIECE RESPIRATOR OR AIRLINED HOOD.
Ventilation: A SYSTEM OF LOCAL EXHAUST IS RECOMMENDED TO KEEP EMPLOYEE
EXPOSURES BELOW THE TLV.
Protective Gloves: NEOPRENE OR RUBBER GLOVES
Eye Protection: CHEMICAL SAFETY GOGGLES WITH FACE SHIELD
Other Equipment: EYE WASH STATION AND SAFETY SHOWER. IMPERVIOUS BOOTS, APRON,
OR COVERALLS AS REQUIRED.
Work Hygenic Practices: EYE WASH STATION AND SAFETY SHOWER. IMPERVIOUS BOOTS,
APRON, OR COVERALLS AS REQUIRED.
Supplemental Safety & Health: NONE
==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
HCC: C1
Boiling Point:
NONE
Melting/Freezing Point:
N/K
Decomposition Temp:
UNKNOWN
Vapor Pressure: NONE Vapor Density: NONE
Specific Gravity: 2.71
PH: NONE
Viscosity: NONE
Evaporation Rate & Reference: NONE
Solubility in Water: COMPLETE
Appearance and Odor: WHITE CRYSTALINE. MAY HAVE FAINT ODOR OF HYDROCHLORIC ACID
Percent Volatiles by Volume: NONE
Corrosion Rate: UNKNOWN
==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: HIGH HEAT, OPEN FLAMES AND OTHER SOURCES OF
IGNITION
Materials to Avoid: STRONG OXIDIZING AGENTS
Hazardous Decomposition Products: WHEN HEATED TO DECOMPOSITION, EMITS TOXIC
HYDROGEN CHLORIDE FUMES. WILL REACT WITH WATER TO PRODUCE HEAT & TOXIC
FUMES.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: NOT APPLICABLE
==============================================================================
TOXICOLOGICAL
==============================================================================
N/P
==============================================================================
ECOLOGICAL
==============================================================================
N/P
==============================================================================
DISPOSAL
==============================================================================
DISPOSAL SHOULD BE MADE IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND
LOCAL LAWS AND REGULATIONS. DISPOSE IN A RCRA-APPROVED WASTE FACILITY OR SEWER
THE NEUTRALIZED SLURRY WITH EXCESS WATER IF LOCAL ORDINANCES ALLOW.
==============================================================================
TRANSPORTATION
==============================================================================
N/P
==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N
==============================================================================
OTHER
==============================================================================
|
|
|
Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals,
Analytical Reagents & Dehydrated Culture Media
|
|
|
|

|
|