CAS
# 10026-06-9 STANNIC CHLORIDE (HYDRATED)
|
|
Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad
- 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300
Fax
: + 91 129 4190333
E-mail: bluluxlab@gmail.com Website
: www.blulux.com
|
|

|
HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: NA Skin: NA Ingestion: NA
Carcinogenicity Inds - NTP: NA IARC: NA OSHA: NA
Health Hazards Acute And Chronic: NA
Explanation of Carcinogenicity: NA
Signs and Symptoms of Overexposure: NA
Medical Conditions Aggravated by Overexposure: NA
==============================================================================
FIRST AID
==============================================================================
NA
==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: N/P
Auto Ignition Temperature Text:
Lower Limits: N/P Upper Limits: N/P
Extinguishing Media: NOT CONSIDERED TO BE A FIRE HAZARD. USE ANY MEANS SUITABLE
FOR EXTINGUISHING SURROUNDING FIRE.
Fire Fighting Procedures: IN THE EVENT OF A FIRE, WEAR FULL PROTECTIVE CLOTHING
& NIOSH-APPROVED SELF-CONTAINED BREATHING APPARATUS WITH FULL FACEPIECE
OPERATED IN THE PRESSURE DEMAND OR OTHER POSITIVE PRESSURE MODE.
Unusal Fire/Explosion Hazard: NOT CONSIDERED TO BE AN EXPLOSION HAZARD.
==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: NA
Neutralizing Agent: NA
Waste Disposal Methods: NA
==============================================================================
HANDLING AND STORAGE
==============================================================================
NA
==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: IF THE TLV IS EXCEEDED, A DUST/MIST NIOSH APPROVED
RESPIRATOR WITH CHEMICAL GOGGLES MAY BE WORN, IN GENERAL, UP TO TEN TIMES THE
TLV. CONSULT RESPIRATOR SUPPLIER FOR LIMITATIONS. ALTERNATIVELY, A NIOSH
APPROVED SUPPLIED AIR FULL FACEPIECE R ESPIRATOR OR AIRLINED HOOD MAY BE WORN.
Ventilation: A SYSTEM OF LOCAL AND/OR GENERAL EXHAUST IS RECOMMENDED TO KEEP
EMPLOYEE EXPOSURES BELOW THE AIRBORNE EXPOSURE LIMITS (ECOLOGICAL INFO).
Protective Gloves: IMPERVIOUS GLOVES.
Eye Protection: CHEMICAL SAFETY GOGGLES &/OR FULL FACE SHIELD WHERE DUSTING
OR (SUPP DAT).
Other Equipment: EYEWASH & DELUGE SHOWER MEETING ANSI DESIGN CRITERIA (FP
N). WEAR IMPERVIOUS PROTECTIVE CLOTHING, INCLUDING BOOTS, GLOVES, LAB COAT,
APRON OR COVERALLS TO PREVENT SKIN CONTACT.
Work Hygenic Practices: EYEWASH & DELUGE SHOWER MEETING ANSI DESIGN
CRITERIA (FP N). WEAR IMPERVIOUS PROTECTIVE CLOTHING, INCLUDING BOOTS, GLOVES,
LAB COAT, APRON OR COVERALLS TO PREVENT SKIN CONTACT.
Supplemental Safety & Health: EYE PROTECTION: SPLASHING OF SOLUTIONS IS
POSSIBLE. CONTACT LENSES SHOULD NOT BE WORN WHEN WORKING WITH THIS MATERIAL.
MAINTAIN EYEWASH FOUNTAIN AND QUICK-DRENCH FACILITIES IN WORK AREA.
==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
Boiling Point:
NO INFO FOUND
Melting/Freezing Point: =56.C, 132.8F
MELTING POINT
Decomposition Temp:
N/P
Vapor Pressure: NO INFO FOUND Vapor Density: NO INFO
Specific Gravity: NO INFO FOUND
PH: N/P
Viscosity: N/P
Evaporation Rate & Reference: NO INFO FOUND
Solubility in Water: SOLUBLE IN WATER
Appearance and Odor: WHITE OR SLIGHTLY YELLOW CRYSTALS. SLIGHT ODOR OF
HYDROCHLORIC ACID.
Percent Volatiles by Volume: N/P
Corrosion Rate: N/P
==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: STABLE UNDER ORDINARY CONDITIONS OF USE AND
STORAGE.
Materials to Avoid: POTASSIUM, SODIUM, AND TURPENTINE.
Hazardous Decomposition Products: EMITS TOXIC FUMES OF CHLORINE WHEN HEATED TO
DECOMPOSITION.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: N/P
==============================================================================
TOXICOLOGICAL
==============================================================================
(RTECS, 1982): NO LD50/LC50 INFORMATION FOUND RELATING TO NORMAL ROUTES OF
OCCUPATIONAL EXPOSURE.
==============================================================================
ECOLOGICAL
==============================================================================
N/P. VENTILATION REQUIREMENTS: LOCAL EXHAUST VENTILATION IS GENERALLY PREFERRED
BECAUSE IT CAN CONTROL THE EMISSIONS OF THE CONTAMINANT AT ITS SOURCE
PREVENTING DISPERSION OF IT INTO THE GENERAL WORK AREA. PLEASE REFER TO THE
ACGIH DOCUM ENT, "INDUSTRIAL VENTILATION, A MANUAL OF RECOMMEDED
PRACTICES", MOST RECENT EDITION, FOR DETAILS.
==============================================================================
DISPOSAL
==============================================================================
NA
==============================================================================
TRANSPORTATION
==============================================================================
CONTACT Blulux Laboratories Pvt. Ltd.
==============================================================================
REGULATORY
==============================================================================
==============================================================================
OTHER
==============================================================================
|
|
|
Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals,
Analytical Reagents & Dehydrated Culture Media
|
|
|
|

|
|