CAS # 7646-78-8 STANNIC CHLORIDE ANHYDROUS {TIN (IV)
CHLORIDE}
|
|
Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad
- 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300
Fax
: + 91 129 4190333
E-mail: bluluxlab@gmail.com Website
: www.blulux.com
|
|

|
HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: NA Skin: NA Ingestion: NA
Carcinogenicity Inds - NTP: NA IARC: NA OSHA: NA
Health Hazards Acute And Chronic: NA
Explanation of Carcinogenicity: NA
Signs and Symptoms of Overexposure: NA
Medical Conditions Aggravated by Overexposure: NA
==============================================================================
FIRST AID
==============================================================================
NA
==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: N/K
Auto Ignition Temperature Text:
Lower Limits: N/K Upper Limits: N/K
Extinguishing Media: USE ANY MEANS SUITABLE FOR EXTINGUISHING SURROUNDING FIRE.
Fire Fighting Procedures: USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT (FP N).
Unusal Fire/Explosion Hazard: FIRE: SLIGHT FIRE HAZARD BY CHEMICAL REACTIONS.
EXPLOSION: NOT CONSIDERED TO BE EXPLOSION HAZARD.
==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: NA
Neutralizing Agent: NA
Waste Disposal Methods: NA
==============================================================================
HANDLING AND STORAGE
==============================================================================
NA
==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: IF TLV IS EXCEEDED A NIOSH APPRVD FULL FACEPIECE CHEM
CARTRIDGE RESP MAY BE WORN, IN GEN, UP TO 100 TIMES TLV/MAX USE CONC SPECIFIED
BY RESP SUPPLIER, WHICHEVER IS LESS. ALTERNATIVELY, A NIOSH APPRVD SUPPLIED AIR
FULL FACEPIECE (SUPDAT)
Ventilation: SYS OF LOC &/OR GEN EXHAUST IS REC TO KEEP EMPLOYEE EXPOS
BELOW AIRBORNE EXPOS LIMITS. LOC EXHAUST VENT IS (SUPDAT)
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGS (ING 3)
Other Equipment: EMERGENCY EYE WASH & DELUGE SHOWER (FP N).
Work Hygenic Practices: EMERGENCY EYE WASH & DELUGE SHOWER (FP N).
Supplemental Safety & Health: SOL IN H*2O: SOLUBLE IN WATER WITH EVOLUTION
OF MUCH HEAT. MATLS TO AVOID: MOISTURE/HEAT. CONSIDERABLE HEAT IS GENERATED
FROM CONT W/MOISTURE. RESP PROT: RESP/AIRLINED HOOD MAY BE WORN. VENT:
GENERALLY PREF BECAUSE IT CAN CTL EMISSIONS OF C ONTAMINANT @ ITS SOURCE, PVNTG
DISPERSION OF IT INTO GEN WORK AREA. (ING 2)
==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
Boiling Point:
237F,114C
Melting/Freezing Point:
-27F,-33C
Decomposition Temp:
N/K
Vapor Pressure: 10 @ 10C Vapor Density: N/K
Specific Gravity: 2.26
PH: N/K
Viscosity: N/P
Evaporation Rate & Reference: NO INFORMATION FOUND
Solubility in Water: SUPP DATA
Appearance and Odor: FUMING CAUSTIC LIQUID.
Percent Volatiles by Volume: N/K
Corrosion Rate: N/K
==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: STABLE UNDER ORDINARY CONDITIONS OF USE AND
STORAGE.
Materials to Avoid: VIOLENT REACTIONS W/POTASSIUM, SODIUM, ETHYLENE OXIDE,
& TURPENTINE. HYDROCHLORIC ACID IS RELEASED ON CONT WITH (SUPDAT)
Hazardous Decomposition Products: EMITS TOXIC FUMES OF CHLORINE WHEN HEATED TO
DECOMPOSITION.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: NOT RELEVANT.
==============================================================================
TOXICOLOGICAL
==============================================================================
N/P
==============================================================================
ECOLOGICAL
==============================================================================
N/P
==============================================================================
DISPOSAL
==============================================================================
NA
==============================================================================
TRANSPORTATION
==============================================================================
N/P
==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: Y
==============================================================================
OTHER
==============================================================================
|
|
|
Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals,
Analytical Reagents & Dehydrated Culture Media
|
|
|
|

|
|