CAS
# 1313-60-6 SODIUM PEROXIDE FOR SYNTHESIS
|
|
Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad
- 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300
Fax
: + 91 129 4190333
E-mail: bluluxlab@gmail.com Website
: www.blulux.com
|
|

|
HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: NA Skin: NA Ingestion: NA
Carcinogenicity Inds - NTP: NA IARC: NA OSHA: NA
Health Hazards Acute And Chronic: NA
Explanation of Carcinogenicity: NA
Signs and Symptoms of Overexposure: NA
Medical Conditions Aggravated by Overexposure: NA
==============================================================================
FIRST AID
==============================================================================
NA
==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: N/K
Auto Ignition Temperature Text:
Lower Limits: N/K Upper Limits: N/K
Extinguishing Media: DRY CHEMICAL. DO NOT USE CARBON DIOXIDE.
Fire Fighting Procedures: USE NIOSH APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT
(FP N).
Unusal Fire/Explosion Hazard: NOT COMBUST BUT SUBSTANCE IS STRONG OXIDIZER
& ITS HEAT OF RXN W/REDUCING AGENTS/COMBUSTS MAY CAUSE IGNITION. CONTACT
W/COMBUST, ORGANIC OR OXIDIZABLE (SUPDAT)
==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: NA
Neutralizing Agent: NA
Waste Disposal Methods: NA
==============================================================================
HANDLING AND STORAGE
==============================================================================
NA
==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: FOR CONDITIONS OF USE WHERE EXPOSURE TO THE DUST IS
APPARENT, A NIOSH APPROVED DUST/MIST RESPIRATOR MAY BE WORN. FOR EMERGENCIES, A
NIOSH APPROVED SELF-CONTAINED BREATHING APPARATUS MAY BE NECESSARY.
Ventilation: LOC EXHST SYSTEM WHICH CAPTURES CONTAMINANT AT ITS SOURCE IS
RECOMD TO PVNT DISPERSION OF CONTAMINANT IN WORKROOM AIR.
Protective Gloves: IMPERVIOUS GLOVES.
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGS (ING 11)
Other Equipment: ANSI APPROVED EYE WASH & DELUGE SHOWER (FP N). WEAR
IMPERVIOUS PROT CLTHG INCLUDING BOOTS, LAB COAT, APRON OR COVERALLS.
Work Hygenic Practices: ANSI APPROVED EYE WASH & DELUGE SHOWER (FP N). WEAR
IMPERVIOUS PROT CLTHG INCLUDING BOOTS, LAB COAT, APRON OR COVERALLS.
Supplemental Safety & Health: BP: 1215F,657C DECOMPOSES. MP: 860F,460C DECOMPOSES.
SOL IN H*2O: REACTS VIOLENTLY W/WATER. EXPLO HAZ: SUBSTANCES MAY CAUSE
EXTREMELY VIOLENT COMBUST. MAY REACT EXPLO IN CONTACT W/LARGE AMOUNTS OF WATER.
MATL TO AVOID: AMMONIUM PERSULFATE, ANILINE, ANTIMONY, ARSENIC, BENZENE, BORON
NITRIDE, CALCIUM CARBIDE, (ING 2)
==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
Boiling Point:
SUPDAT
Melting/Freezing Point:
SUPDAT
Decomposition Temp:
N/K
Vapor Pressure: N/K Vapor Density: N/K
Specific Gravity: 2.81
PH: N/K
Viscosity: N/P
Evaporation Rate & Reference: N/K
Solubility in Water: SUPDAT
Appearance and Odor: WHITE TO PALE YELLOW GRANULES; ODORLESS.
Percent Volatiles by Volume: N/K
Corrosion Rate: N/K
==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: STABLE UNDER ORDINARY CONDITIONS OF USE AND
STORAGE. WATER REACTIVE.
Materials to Avoid: MOISTURE, ORG & OXIDIZABLE SUBSTANCES, ACETIC ACID,
ACETIC ANHYDRIDE, ALUMINUM, ALUMINUM PLUS CARBON DIOXIDE, (SUPDAT)
Hazardous Decomposition Products: EMITS OXYGEN WHEN HEATED TO DECOMPOSITION
WHICH MAY INCREASE A FIRE HAZARD.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: NOT RELEVANT
==============================================================================
TOXICOLOGICAL
==============================================================================
N/P
==============================================================================
ECOLOGICAL
==============================================================================
N/P
==============================================================================
DISPOSAL
==============================================================================
NA
==============================================================================
TRANSPORTATION
==============================================================================
N/P
==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N
==============================================================================
OTHER
==============================================================================
|
|
|
Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals,
Analytical Reagents & Dehydrated Culture Media
|
|
|
|

|
|