> Blulux Laboratories Pvt. Ltd.

CAS#12520-88-6 SILICOTUNGSTIC ACID AR

Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad - 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300 
Fax : + 91 129 4190333
E-mail: bluluxlab@gmail.com  Website : www.blulux.com


 

HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: NO
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO

Health Hazards Acute And Chronic: ACUTE: INHALATION: HARMFUL AND MAY BE FATAL. SKIN/EYES: SEVERE IRRITATION OR BURNS. INGESTION: IRRITATION AND BURNS TO MOUTH AND STOMACH. CHRONIC: NONE INFORMATION FOUND.

Explanation of Carcinogenicity: N/P

Signs and Symptoms of Overexposure: SEE HEALTH HAZARDS.

Medical Conditions Aggravated by Overexposure: NO INFORMATION FOUND.

==============================================================================
FIRST AID
==============================================================================
INHAL: REMOVE TO FRESH AIR. IF NOT BREATHING, GIVE ARTF RESP. IF BREATHING IS DIFFICULT, GIVE OXYGEN. PROMPT ACTION IS ESSENTIAL. INGESTION: IF SWALLOWED, DO NOT INDUCE VOMITING. GIVE LARGE QUANTITIES OF WATER. NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. GET MEDICAL ATTENTION IMMEDIATELY. SKIN: IMMEDIATELY FLUSH W/PLENTY OF WATER FOR AT LEAST 15 MINUTES WHILE REMOVING CONTAMINATED CLOTHING & SHOES. WASH CLOTHING BEFORE RE-USE. EYES: IMMEDIATELY FLUSH W/PLENTY OF W ATER FOR AT LEAST 15 MINUTES.

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: N/P

Auto Ignition Temperature Text: 

Extinguishing Media: USE EXTINGUISHING MEDIA APPROPRIATE FOR SURROUNDING FIRE.

Fire Fighting Procedures: USE NIOSH/MSHA APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT (FP N).

Unusal Fire/Explosion Hazard: NONE IDENTIFIED.

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: WEAR NIOSH APPROVED SELF-CONTAINED BREATHING APPARATUS AND FULL PROTECTIVE CLOTHING. WITH CLEAN SHOVEL, CAREFULLY PLACE MATERIAL INTO CLEAN, DRY CONTAINER AND COVER; REMOVE FROM AREA. FLUSH SPILL AREA WITH WATER.
Neutralizing Agent: N/P

Waste Disposal Methods: WHATEVER CANNOT BE SAVED FOR RECOVERY/RECYCLING SHOULD BE MANAGED IN APPROPRIATE & APPROVED WASTE DISPOSAL FACILITY. PROCESSING, USE/CONTAM OF THIS PRODUCT MAY CHANGE WASTE MANAGEMENT OPTIONS. STATE & LOCAL DISPOSAL REGULATIONS MAY DIFFER F ROM FED DISPOSAL REGULATIONS. DISPOSE OF CONTAINER & UNUSED CONTENTS I/A/W/FED, STATE & LOCAL REQUIREMENTS.

==============================================================================
HANDLING AND STORAGE
==============================================================================
KEEP CONTAINER TIGHTLY CLOSED. STORE IN CORROSION-PROOF AREA. CONTAINERS OF THIS MATERIAL MAY BE HAZARDOUS WHEN EMPTY SINCE THEY RETAIN PRODUCT RESIDUES (DUST, SOLIDS); OBSERVE ALL WARNINGS AND PRECAUTIONS LISTED FOR THE PRODUCT.

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: FOR CONDITIONS OF USE WHERE EXPOSURE TO THE SUBSTANCE IS APPARENT, CONSULT AN INDUSTRIAL HYGIENIST. FOR EMERGENCIES, OR INSTANCES WHERE THE EXPOSURE LEVELS ARE NOT KNOWN; USE A NIOSH APPROVED FULL-FACEPIECE POSITIVE-PRESSURE, AIR-SUPPLIED R ESPIRATOR. WARNING: AIR PURIFYING RESPIRATORS DO NOT PROTECT WORKERS IN OXYGEN-DEFICIENT ATMOSPHERES.
Ventilation: SYS OF LOC &/GEN EXHST IS REC TO KEEP EMPLOYEE EXPOS AS LOW AS POSS. LOC EXHST VENT IS GENERALLY PREFERRED BECAUSE IT CAN CONTROL EMISSIONS OF (SUPDAT)
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGS & FULL LENGTH FACESHIELD (FP N)
Other Equipment: EMERGENCY EYE WASH & DELUGE SHOWER MEETING ANSI DESIGN CRITERIA (FP N). WEAR IMPERVIOUS PROTECTIVE CLOTHING, INCLUDING BOOTS, GLOVES, LAB COAT, APRON/COVERALLS, AS APPROPRIATE, TO PREVENT SKIN CONTACT.
Work Hygenic Practices: EMERGENCY EYE WASH & DELUGE SHOWER MEETING ANSI DESIGN CRITERIA (FP N). WEAR IMPERVIOUS PROTECTIVE CLOTHING, INCLUDING BOOTS, GLOVES, LAB COAT, APRON/COVERALLS, AS APPROPRIATE, TO PREVENT SKIN CONTACT.
Supplemental Safety & Health: VENT: OF THE CONTAMINANT AT ITS SOURCE, PREVENTING DISPERSION OF IT INTO THE GENERAL WORK AREA. PLEASE REFER TO ACGIH DOCUMENT, INDUSTRIAL VENTILATION, A MANUAL OF RECOMMENED PRACTICES, MOST RECENT EDITION, FOR DETAILS.

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
Boiling Point: 
N/K
Melting/Freezing Point: 
N/K
Decomposition Temp: 
N/K
Vapor Pressure: N/A Vapor Density: N/A
Specific Gravity: N/K
PH: N/K
Viscosity: N/P
Evaporation Rate & Reference: N/K
Solubility in Water: COMPLETE (100%)
Appearance and Odor: WHITE TO LIGHT YELLOW CRYSTALLINE SOLID; NO INFORMATION FOUND ON ODOR.
Percent Volatiles by Volume: 0
Corrosion Rate: N/K

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: NO INFORMATION FOUND.
Materials to Avoid: STRONG BASES.
Hazardous Decomposition Products: NO INFORMATION FOUND.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: WILL NOT OCCUR.

==============================================================================
TOXICOLOGICAL
==============================================================================
INGREDIENT: SILICOTUGSTIC ACID (12027-38-2): NTP CARCINOGEN: KNOWN, & ANTICIPATED: NO. IARC CATEGORY: NONE.

==============================================================================
ECOLOGICAL
==============================================================================
INGREDIENT: SILICOTUGSTIC ACID (12027-38-2): NTP CARCINOGEN: KNOWN, & ANTICIPATED: NO. IARC CATEGORY: NONE.

==============================================================================
DISPOSAL
==============================================================================
WHATEVER CANNOT BE SAVED FOR RECOVERY/RECYCLING SHOULD BE MANAGED IN APPROPRIATE & APPROVED WASTE DISPOSAL FACILITY. PROCESSING, USE/CONTAM OF THIS PRODUCT MAY CHANGE WASTE MANAGEMENT OPTIONS. STATE & LOCAL DISPOSAL REGULATIONS MAY DIFFER F ROM FED DISPOSAL REGULATIONS. DISPOSE OF CONTAINER & UNUSED CONTENTS I/A/W/FED, STATE & LOCAL REQUIREMENTS.

==============================================================================
TRANSPORTATION
==============================================================================
CONTACT Blulux Laboratories Pvt. Ltd.
==============================================================================
REGULATORY
==============================================================================
SARA Title III: LABEL HAZARD WARNING: POISON! DANGER! CAUSES BURNS. MAY BE FATAL IF SWALLOWED OR INHALED. LABEL PRECAUTIONS: DO NOT GET IN EYES, ON SKIN, ON CLOTHING. DO NOT BREATHE DUST. KEEP IN TIGHTLY CLOSED CONTAINER. USE WITH ADEQUATE VENTILATION. WA SH THOROUGHLY AFTER HANDLING. LABEL FIRST AID: IF SWALLOWED, DO NOT INDUCE VOMITING. GIVE LARGE QUANTITIES OF WATER. NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. IF INHALED, REMOVE TO FRESH AIR. IF NOT BREATHING, GIVE ARTIFICIAL RESPIRATION. IF BREATHING IS DIFFICULT, GIVE OXYGEN. PROMPT ACTION IS ESSENTIAL. PRODUCT USE LABORATORY REAGENT.
Federal Regulatory: N
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media