> Blulux Laboratories Pvt. Ltd.

CAS # 113-24-6 PYRUVIC ACID

Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad - 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300 
Fax : + 91 129 4190333
E-mail: bluluxlab@gmail.com  Website : www.blulux.com


 

HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: YES
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO

Health Hazards Acute And Chronic: INHALATION: NO ADVERSE HEALTH EFFECTS EXPECTED FROM INHALATION. INGESTION: LARGE DOSES MAY CAUSE GASTROINTESTINAL UPSET. SKIN CONTACT: NO ADVERSE EFFECTS EXPECTED. EYE CONTACT: NO ADVERSE EFFECTS EXPECTED. CHRONIC EXPOSURE: NO INFORMATION F OUND.

Explanation of Carcinogenicity: N/P

Signs and Symptoms of Overexposure: SEE HEALTH HAZARDS.

Medical Conditions Aggravated by Overexposure: NO INFORMATION FOUND.

==============================================================================
FIRST AID
==============================================================================
INHALATION: REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE OXYGEN/ARTIFICIAL RESPIRATION) (FP N). NOT EXPECTED TO REQUIRE FIRST AID MEASURES. INGESTION: IF LARGE AMOUNTS WERE SWALLOWED, GIVE WATER TO DRINK AND GET MEDICAL ADVICE. SKIN CONTACT : WASH EXPOSED AREA WITH SOAP AND WATER. GET MEDICAL ADVICE IF IRRITATION DEVELOPS. EYE CONTACT: IN CASE OF CONTACT, IMMEDIATELY FLUSH EYES WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES, LIFTING UPPER AND LOWER EYELIDS OCCASIONALLY. CALL A P HYSICIAN IF IRRITATION PERSISTS.

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: N/P

Auto Ignition Temperature Text: 

Extinguishing Media: WATER SPRAY, DRY CHEMICAL, ALCOHOL FOAM OR CARBON DIOXIDE.

Fire Fighting Procedures: USE NIOSH APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT (FP N).

Unusal Fire/Explosion Hazard: FIRE: AS WITH MOST ORGANIC SOLIDS, FIRE IS POSSIBLE AT ELEVATED TEMPERATURES OR BY CONTACT WITH AN IGNITION SOURCE. EXPLOSION: FINE DUST DISPERSED IN AIR IN SUFFICIENT CONCENTRATIONS, AND IN THE PRESENCE OF AN IGNITION SOURCE IS A POTENTIAL DUST EXPLOSIO HAZARD.

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: REMOVE ALL SOURCES OF IGNITION. VENTILATE AREA OF LEAK OR SPILL. WEAR APPROP PERSONAL PROTECTIVE EQUIP AS SPECIFIED IN SECTION ON EXPOSURE CONTROLS/PERSONAL PROTECTION. CLEAN UP SPILLS IN MANNER THAT DOES NOT DISPERSE DUST INTO AIR. USE NON -SPKG TOOLS & EQUIP. REDUCE AIRBORNE DUST & PVNT SCATTERING BY MOISTENING W/WATER. PICK UP SPILL FOR RECOVERY OR DISPOSAL & PLACE IN A CLOSED CONTAINER.
Neutralizing Agent: N/P

Waste Disposal Methods: WHATEVER CANNOT BE SAVED FOR RECOVERY OR RECYCLING SHOULD BE MANAGED IN APPROP & APPRVD WASTE DISP FACILITY. PROCESSING, USE OR CONTAM OF THIS PROD MAY CHANGE WASTE MANAGEMENT OPTIONS. STATE & LOCAL DISP REGS MAY DIFFER FROM FED DISP REGS. DISPOSE OF CNTNR & UNUSED CONTENTS I/A/W FED, STATE & LOCAL REQS.

==============================================================================
HANDLING AND STORAGE
==============================================================================
KEEP IN TIGHTLY CLSD CNTNR, STORED IN COOL, DRY, VENTD AREA. PROTECT AGAINST PHYSICAL DMG. AVOID DUST FORM & CONTROL IGNIT SOURCES. EMPLOY GROUNDING, VENTING & EXPLOSION RELIEF PROVISIONS I/A/W ACCEPTED ENGINEERING PRACTS IN ANY PROCESS CAP ABLE OF GENERATING DUST &/OR STATIC ELEC. EMPTY (SUPDAT)

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: PERSONAL RESPIRATORS (NIOSH APPROVED): FOR CNDTNS OF USE WHERE EXPOS TO DUST OR MIST IS APPARENT, A HALF-FACE DUST/MIST RESPIRATOR MAY BE WORN. FOR EMERGENCIES OR INSTANCES WHERE THE EXPOS LEVELS ARE NOT KNOWN, USE A FULL-FACE POSITIVE-PESS URE, AIR-SUPPLIED RESPIRATOR. WARNING: AIR-PURIFYING RESPIRATORS DO NOT PROTECT WORKERS IN OXYGEN-DEFICIENT ATMOSPHERES.
Ventilation: IN GEN, DILUTION VENT IS SATISFACTORY HLTH HAZ CTL FOR THIS SUBSTANCE. HOWEVER, IF CNDTNS OF USE CREATE WORKER DISCOMFORT, LOC EXHST SYS SHOULD BE CONSIDERED.
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPROVED CHEMICAL WORKERS GOGGLES (FP N).
Other Equipment: EYE WASH AND DELUGE SHOWER MEETING ANSI DESIGN CRITERIA (FP N). WEAR CLEAN BODY-COVERING CLOTHING.
Work Hygenic Practices: EYE WASH AND DELUGE SHOWER MEETING ANSI DESIGN CRITERIA (FP N). WEAR CLEAN BODY-COVERING CLOTHING.
Supplemental Safety & Health: HNDLG/STOR PRECS: ONLY INTO INERT OR NON-FLAM ATMOSPHERE. EMPTYING CONTENTS INTO NON-INERT ATMOSPHERE WHERE FLAMMABLE VAPS MAY BE PRESENT COULD CAUSE FLASH FIRE OR EXPLOSION DUE TO ELECTROSTATIC DISCHARGE. AIRBORNE EXPOSURE LIMITS: NONE EST ABLISHED.

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
Boiling Point: 
NO INFO FOUND
Melting/Freezing Point: >300.C, 572.F

Decomposition Temp: 
N/P
Vapor Pressure: NO INFO FOUND Vapor Density: NO INFO
Specific Gravity: NO INFO FOUND
PH: 7(10% IN WATER)
Viscosity: N/P
Evaporation Rate & Reference: NO INFO FOUND
Solubility in Water: COMPLETELY
Appearance and Odor: WHITE POWDER; ODORLESS.
Percent Volatiles by Volume: 0 @ 21C
Corrosion Rate: N/P

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: STABLE UNDER ORDINARY CONDITIONS OF USE AND STORAGE. AVOID HEAT, INCOMPATIBLES.
Materials to Avoid: STRONG OXIDIZERS.
Hazardous Decomposition Products: CARBON DIOXIDE AND CARBON MONOXIDE MAY FORM WHEN HEATED TO DECOMPOSITION.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: N/P

==============================================================================
TOXICOLOGICAL
==============================================================================
NO LD50/LC50 INFORMATION FOUND RELATING TO NORMAL ROUTES OF OCCUPATIONAL EXPOSURE. CANCER LISTS - PYRUVIC ACID, SODIUM SALT (113-24-6): NTP CARCINOGEN, KNOWN-NO, ANTICIPATED-NO; IARC CATEGORY: NONE.

==============================================================================
ECOLOGICAL
==============================================================================
ENVIRONMENTAL FATE: NO INFORMATION FOUND. ENVIRONMENTAL TOXICITY: NO INFORMATION FOUND.

==============================================================================
DISPOSAL
==============================================================================
WHATEVER CANNOT BE SAVED FOR RECOVERY OR RECYCLING SHOULD BE MANAGED IN APPROP & APPRVD WASTE DISP FACILITY. PROCESSING, USE OR CONTAM OF THIS PROD MAY CHANGE WASTE MANAGEMENT OPTIONS. STATE & LOCAL DISP REGS MAY DIFFER FROM FED DISP REGS. DISPOSE OF CNTNR & UNUSED CONTENTS I/A/W FED, STATE & LOCAL REQS.

==============================================================================
TRANSPORTATION
==============================================================================
CONTACT Blulux Laboratories Pvt. Ltd.
==============================================================================
REGULATORY
==============================================================================
Federal Regulatory: N
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media