HAZARD
IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: YES
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO
Health Hazards Acute And Chronic: INHALATION: NO ADVERSE HEALTH EFFECTS
EXPECTED FROM INHALATION. INGESTION: LARGE DOSES MAY CAUSE GASTROINTESTINAL
UPSET. SKIN CONTACT: NO ADVERSE EFFECTS EXPECTED. EYE CONTACT: NO ADVERSE
EFFECTS EXPECTED. CHRONIC EXPOSURE: NO INFORMATION F OUND.
Explanation of Carcinogenicity: N/P
Signs and Symptoms of Overexposure: SEE HEALTH HAZARDS.
Medical Conditions Aggravated by Overexposure: NO INFORMATION FOUND.
==============================================================================
FIRST AID
==============================================================================
INHALATION: REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE OXYGEN/ARTIFICIAL
RESPIRATION) (FP N). NOT EXPECTED TO REQUIRE FIRST AID MEASURES. INGESTION: IF
LARGE AMOUNTS WERE SWALLOWED, GIVE WATER TO DRINK AND GET MEDICAL ADVICE. SKIN
CONTACT : WASH EXPOSED AREA WITH SOAP AND WATER. GET MEDICAL ADVICE IF
IRRITATION DEVELOPS. EYE CONTACT: IN CASE OF CONTACT, IMMEDIATELY FLUSH EYES
WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES, LIFTING UPPER AND LOWER EYELIDS
OCCASIONALLY. CALL A P HYSICIAN IF IRRITATION PERSISTS.
==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: N/P
Auto Ignition Temperature Text:
Extinguishing Media: WATER SPRAY, DRY CHEMICAL, ALCOHOL FOAM OR CARBON DIOXIDE.
Fire Fighting Procedures: USE NIOSH APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT
(FP N).
Unusal Fire/Explosion Hazard: FIRE: AS WITH MOST ORGANIC SOLIDS, FIRE IS
POSSIBLE AT ELEVATED TEMPERATURES OR BY CONTACT WITH AN IGNITION SOURCE.
EXPLOSION: FINE DUST DISPERSED IN AIR IN SUFFICIENT CONCENTRATIONS, AND IN THE
PRESENCE OF AN IGNITION SOURCE IS A POTENTIAL DUST EXPLOSIO HAZARD.
==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: REMOVE ALL SOURCES OF IGNITION. VENTILATE AREA OF
LEAK OR SPILL. WEAR APPROP PERSONAL PROTECTIVE EQUIP AS SPECIFIED IN SECTION ON
EXPOSURE CONTROLS/PERSONAL PROTECTION. CLEAN UP SPILLS IN MANNER THAT DOES NOT
DISPERSE DUST INTO AIR. USE NON -SPKG TOOLS & EQUIP. REDUCE AIRBORNE DUST
& PVNT SCATTERING BY MOISTENING W/WATER. PICK UP SPILL FOR RECOVERY OR
DISPOSAL & PLACE IN A CLOSED CONTAINER.
Neutralizing Agent: N/P
Waste Disposal Methods: WHATEVER CANNOT BE SAVED FOR RECOVERY OR RECYCLING
SHOULD BE MANAGED IN APPROP & APPRVD WASTE DISP FACILITY. PROCESSING, USE
OR CONTAM OF THIS PROD MAY CHANGE WASTE MANAGEMENT OPTIONS. STATE & LOCAL
DISP REGS MAY DIFFER FROM FED DISP REGS. DISPOSE OF CNTNR & UNUSED CONTENTS
I/A/W FED, STATE & LOCAL REQS.
==============================================================================
HANDLING AND STORAGE
==============================================================================
KEEP IN TIGHTLY CLSD CNTNR, STORED IN COOL, DRY, VENTD AREA. PROTECT AGAINST
PHYSICAL DMG. AVOID DUST FORM & CONTROL IGNIT SOURCES. EMPLOY GROUNDING,
VENTING & EXPLOSION RELIEF PROVISIONS I/A/W ACCEPTED ENGINEERING PRACTS IN
ANY PROCESS CAP ABLE OF GENERATING DUST &/OR STATIC ELEC. EMPTY (SUPDAT)
==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: PERSONAL RESPIRATORS (NIOSH APPROVED): FOR CNDTNS OF
USE WHERE EXPOS TO DUST OR MIST IS APPARENT, A HALF-FACE DUST/MIST RESPIRATOR
MAY BE WORN. FOR EMERGENCIES OR INSTANCES WHERE THE EXPOS LEVELS ARE NOT KNOWN,
USE A FULL-FACE POSITIVE-PESS URE, AIR-SUPPLIED RESPIRATOR. WARNING:
AIR-PURIFYING RESPIRATORS DO NOT PROTECT WORKERS IN OXYGEN-DEFICIENT
ATMOSPHERES.
Ventilation: IN GEN, DILUTION VENT IS SATISFACTORY HLTH HAZ CTL FOR THIS
SUBSTANCE. HOWEVER, IF CNDTNS OF USE CREATE WORKER DISCOMFORT, LOC EXHST SYS
SHOULD BE CONSIDERED.
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPROVED CHEMICAL WORKERS GOGGLES (FP N).
Other Equipment: EYE WASH AND DELUGE SHOWER MEETING ANSI DESIGN CRITERIA (FP
N). WEAR CLEAN BODY-COVERING CLOTHING.
Work Hygenic Practices: EYE WASH AND DELUGE SHOWER MEETING ANSI DESIGN CRITERIA
(FP N). WEAR CLEAN BODY-COVERING CLOTHING.
Supplemental Safety & Health: HNDLG/STOR PRECS: ONLY INTO INERT OR NON-FLAM
ATMOSPHERE. EMPTYING CONTENTS INTO NON-INERT ATMOSPHERE WHERE FLAMMABLE VAPS
MAY BE PRESENT COULD CAUSE FLASH FIRE OR EXPLOSION DUE TO ELECTROSTATIC
DISCHARGE. AIRBORNE EXPOSURE LIMITS: NONE EST ABLISHED.
==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
Boiling Point:
NO INFO FOUND
Melting/Freezing Point: >300.C, 572.F
Decomposition Temp:
N/P
Vapor Pressure: NO INFO FOUND Vapor Density: NO INFO
Specific Gravity: NO INFO FOUND
PH: 7(10% IN WATER)
Viscosity: N/P
Evaporation Rate & Reference: NO INFO FOUND
Solubility in Water: COMPLETELY
Appearance and Odor: WHITE POWDER; ODORLESS.
Percent Volatiles by Volume: 0 @ 21C
Corrosion Rate: N/P
==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: STABLE UNDER ORDINARY CONDITIONS OF USE AND STORAGE.
AVOID HEAT, INCOMPATIBLES.
Materials to Avoid: STRONG OXIDIZERS.
Hazardous Decomposition Products: CARBON DIOXIDE AND CARBON MONOXIDE MAY FORM
WHEN HEATED TO DECOMPOSITION.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: N/P
==============================================================================
TOXICOLOGICAL
==============================================================================
NO LD50/LC50 INFORMATION FOUND RELATING TO NORMAL ROUTES OF OCCUPATIONAL
EXPOSURE. CANCER LISTS - PYRUVIC ACID, SODIUM SALT (113-24-6): NTP CARCINOGEN,
KNOWN-NO, ANTICIPATED-NO; IARC CATEGORY: NONE.
==============================================================================
ECOLOGICAL
==============================================================================
ENVIRONMENTAL FATE: NO INFORMATION FOUND. ENVIRONMENTAL TOXICITY: NO
INFORMATION FOUND.
==============================================================================
DISPOSAL
==============================================================================
WHATEVER CANNOT BE SAVED FOR RECOVERY OR RECYCLING SHOULD BE MANAGED IN APPROP
& APPRVD WASTE DISP FACILITY. PROCESSING, USE OR CONTAM OF THIS PROD MAY
CHANGE WASTE MANAGEMENT OPTIONS. STATE & LOCAL DISP REGS MAY DIFFER FROM
FED DISP REGS. DISPOSE OF CNTNR & UNUSED CONTENTS I/A/W FED, STATE &
LOCAL REQS.
==============================================================================
TRANSPORTATION
==============================================================================
CONTACT Blulux Laboratories Pvt. Ltd.
==============================================================================
REGULATORY
==============================================================================
Federal Regulatory: N
==============================================================================
OTHER
==============================================================================
Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical
Reagents & Dehydrated Culture Media