CAS
# 7790-58-1 POTASSIUM TELLURITE
|
|
Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad
- 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300
Fax
: + 91 129 4190333
E-mail: bluluxlab@gmail.com Website
: www.blulux.com
|
|

|
K2TeO3
M.W. 253.80
Minimum
assay (ex
Te)
90%
Maximum
Limits of Impurities
Chloride
(CI)
`0.005%
Nitrate
(NO3)
0.005%
Sulphate
(SO4)
Passes test
Iron
(Fe)
0.002%
------------------------------------------------------------------------------
Section IV Fire or Explosion Hazard
------------------------------------------------------------------------------
Conditions of Flammability: Noncombustible
Extinguishing Media: Use an extinguisher appropriate to the surrounding
material that is burning. Firefighters should wear self-contained breathing
apparatus.
Flash point / method: Not
applicable
UEL: Not
applicable
LEL: Not applicable
Auto ignition Temperature: Not applicable
Hazardous Combustion Products: Te, TeOx
Explosion data - sensitivity to mechanical impact: No
- sensitivity to static discharge: No
------------------------------------------------------------------------------
Section V Reactivity Data
------------------------------------------------------------------------------
Conditions of instability: Stable, if kept dry
Incompatibilities: Acids
Conditions of reactivity: Normally stable
Hazardous decomposition products: Te, TeOx
------------------------------------------------------------------------------
Section VI Toxicological
Properties / Health Hazard Data
------------------------------------------------------------------------------
Route of entry:
-skin contact: Irritates
-skin absorption: Toxic
-eye contact: Irritates
-inhalation: Toxic
-ingestion: Toxic
LC50: Not available
LD50: Not available
Exposure Limits: TLV: 0.1 mg/m3 (Tellurium)
Effects of Acute Exposure: Toxic signs may include vomiting, renal pain,
stupor, loss of consciousness, irregular breathing and cyanosis.
Effects of Chronic Exposure: Prolonged exposure to this product will
affect the central nervous systems and the kidneys.
Irritancy: No experimental information avialable
Sensitization to Product: No information available
Carcinogenicity: No information available
Reproductive Toxicity: No information available
Teratogenicity: No information available
Mutagenicity: No information available
Toxicologically Synergistic Products: None found
------------------------------------------------------------------------------
Section VII First aid measures
------------------------------------------------------------------------------
Skin: Flush the contact area with lukewarm running water for at least 15
minutes. Remove contaminated clothing, taking care not to spread the chemical.
If contamination is extensive, remove clothing under running water. Discard or
decontaminate clothing under running water. Discard or decontaminate clothing
before use. Unless contact has been slight, seek medical attention. Seek
medical attention if irritation persists.
Eye: Flush the contaminated eye(s) for at least 15 minutes with lukewarm
running water, holding the eyelids open. Take care not to rinse contaminated
water into the non-affected eye. Always seek medical attention for accidents
involving the eyes.
Inhalation: Take proper precautions to ensure your own safety before
attempting rescue. Remove source of contamination or move victim to fresh air.
If breathing has stopped, trained personnel should begin artificial
respiration, or if the heart has stopped, cardiopulmonary resuscitation (CPR)
immediately. Seek medical attention.
Ingestion: Never give anything by mouth if victim is rapidly losing
consciousness, or is unconscious or convulsing. Rinse mouth thoroughly with
water. If conscious, induce vomiting. Have victim drink 200-400 ml of water to
dilute. If breathing has stopped, trained personnel should begin artificial
respiration, or if the heart has stopped, cardiopulmonary resuscitation (CPR)
immediately. Seek medical attention.
------------------------------------------------------------------------------
Section VIII Preventive Measures
------------------------------------------------------------------------------
Engineering Controls: Engineering control methods to reduce hazardous
exposures are preferred. Methods include mechanical ventilation (dilution and
local exhaust), process or personnel enclosure, control of process conditions,
and
process modification. Administrative controls and personal protective equipment
may also be required.
Personal protective equipment:
-gloves: Rubber or plastic
-respiratory protection: Dust mask, approved respirator as
appropriate
-eye protection: Chemical safety goggles or face shield
-clothing: Plastic apron, sleeves and boots as appropriate
Storage Requirements: Store in suitable labeled containers. Keep
containers tightly closed when not in use and when empty. Protect from damage.
Protect from moisture. Store in a cool, dry, well-ventilated area, out of
direct sunlight.
Handling Procedures and Equipment: Avoid generating dust. Follow routine
safe handling procedures.
Leak or Spill Clean-up: Before dealing with spillages take necessary
protective measures, inform others to keep at a safe distance and, for
flammable materials, shut off all possible sources of ignition. Transfer
carefully into container and arrange removal by disposal company. Wash site of
spillage thoroughly with water and detergent.
Disposal: Follow all federal, provincial and local regulations for
disposal. Use only licensed disposal and waste hauling companies. Disposal of
small amounts of spilled material may be handled as described under "Leak
or Spill
Cleanup". Large spills must be dealt with separately and must be handled
by qualified disposal companies.
________________________________________________________________________________________
Preparation Information
________________________________________________________________________________________
Prepared by: BLULUX LABORATORIES (P) LTD.
For questions contact: Blulux Laboratories
Pvt. Ltd.
79/66-B, I.H.I.Complex, Industrial Area, N.I.T. Faridabad,
Haryana-121001
The
statements contained herein are offered for informational purposes only and are
based upon technical data that Blulux Laboratories Pvt. Ltd. believes to be
accurate. It is intended for use only by persons having the necessary technical
skills and at their own discretion and risk. Since conditions and manner of use
are outside our control, we make NO WARRANTY, EXPRESS OR IMPLIED, OF
MERCHANTABILITY, FITNESS OR OTHERWISE.
|
|
|
Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical
Reagents & Dehydrated Culture Media
|
|
|
|

|