> Blulux Laboratories Pvt. Ltd.

CAS # 16921-30-5 POTASSIUM CHLOROPLATINATE

Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad - 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300 
Fax : + 91 129 4190333
E-mail: bluluxlab@gmail.com  Website : www.blulux.com


 

HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: YES
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO

Health Hazards Acute And Chronic: ACUTE/CHONIC: MUTAGENIC DATA EXISTS. OVEREXPOSURE CAN CAUSE ASTHMA AND DERMATITIS. MAY INCLUDE MODERATE TO SEVERE ERYTHEMA(REDNESS) & MODERATE EDEMA (RAISED SKIN).

Explanation of Carcinogenicity: NOT RELEVANT.

Signs and Symptoms of Overexposure: SEE HEALTH HAZARDS.

Medical Conditions Aggravated by Overexposure: NONE SPECIFIED BY MANUFACTURER.

==============================================================================
FIRST AID
==============================================================================
SKIN: REMOVE CONTAMD CLTHG & RINSE W/COPIOUS AMTS OF SOAP & WATER FOR A CONSIDERABLE AMT OF TIME. CALL MD. INGEST: DRINK 1 OR 2 GLASSES OF WATER. CALL MD/TAKE PATIENT TO HOSP. EYES:RINSE LIBERALLY W/WATER AT LEAST 15 MINS. CALL MD/TAKE PATI ENT TO HOSPITAL. INHAL: TAKE PATIENT INTO FRESH AIR & ALLOW TO REST. CALL MD/TAKE PATIENT TO HOSPITAL. OBSERVE PROPER LAB PROCS WHEN HNDLG MATL.

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: N/K

Auto Ignition Temperature Text: 

Lower Limits: N/K Upper Limits: N/K

Extinguishing Media: CO*2, DRY CHEMICAL OR FOAM.

Fire Fighting Procedures: WEAR NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE EQUIPMENT(FP N).

Unusal Fire/Explosion Hazard: NONE SPECIFIED BY MANUFACTURER.

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: SWEEP INTO SUITABLE CONTAINER FOR PROPER DISPOSAL.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.

Waste Disposal Methods: INCINERATE OR LANDFILL AS COMPLIES WITH STATE, LOCAL & FEDERAL LAWS.

==============================================================================
HANDLING AND STORAGE
==============================================================================
ALWAYS WEAR GLOVES, MASK, GOGGLES OR OTHER PROTECTIVE CLOTHING & USE A HOOD. FOLLOW PROPER LABORATORY PROCEDURES.

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN(F PN).
Ventilation: YES.
Protective Gloves: IMPERVIOUS GLOVES(FP N).
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGS(FP N).
Other Equipment: EMERGENCY EYEWASH & DELUGE SHOWER MEETING ANSI DESIGN CRITERIA(FP N).
Work Hygenic Practices: EMERGENCY EYEWASH & DELUGE SHOWER MEETING ANSI DESIGN CRITERIA(FP N).
Supplemental Safety & Health: NONE SPECIFIED BY MANUFACTURER.

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
Boiling Point: 
N/K
Melting/Freezing Point: 
482F,250C
Decomposition Temp: 
N/K
Vapor Pressure: N/K Vapor Density: N/K
Specific Gravity: 3.500
PH: N/K
Viscosity: N/P
Evaporation Rate & Reference: N/K
Solubility in Water: N/K
Appearance and Odor: YELLOW POWDER.
Percent Volatiles by Volume: N/K
Corrosion Rate: N/K

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: NONE SPECIFIED BY MANUFACTURER.
Materials to Avoid: NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products: TOXIC FUMES OF K*2O & CL.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: NOT RELEVANT.

==============================================================================
TOXICOLOGICAL
==============================================================================
N/P

==============================================================================
ECOLOGICAL
==============================================================================
N/P

==============================================================================
DISPOSAL
==============================================================================
INCINERATE OR LANDFILL AS COMPLIES WITH STATE, LOCAL & FEDERAL LAWS.

==============================================================================
TRANSPORTATION
==============================================================================
N/P

==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media