HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: YES
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO

Health Hazards Acute And Chronic: HARMFUL IF SWALLOWED, INHALED OR ABSORBED THROUGH SKIN. MAY CAUSE IRRITATION.

Explanation of Carcinogenicity: POSSIBLE CARCINOGEN PER MFG STUDIES.

Signs and Symptoms of Overexposure: POSSIBLE RISK OF IRREVERSIBLE EFFECTS.

Medical Conditions Aggravated by Overexposure: N/K

==============================================================================
FIRST AID
==============================================================================
EYES/SKIN: FLUSH W/PLENTY OF WATER FOR AT LEAST 15 MINS WHILE REMOVING CONTAMINATED CLOTHING & SHOES. INHALATION: REMOVE TO FRESH AIR. IF NOT BREATHING GIVE ARTIFICIAL RESPIRATION. IF BREATHING IS DIFFICULT, GIVE OXYGEN. INGESTION: WASH OUT MOUTH W/WATER PROVIDED PERSON IS CONSCIOUS. DISCARD CONTAMINATED CLOTHING & SHOES. OBTAIN MEDICAL ATTENTION IN ALL CASES.

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: N/K

Auto Ignition Temperature Text: 

Lower Limits: N/K Upper Limits: N/K

Extinguishing Media: CO2, DRY CHEMICAL OR APPROPRIATE FOAM.

Fire Fighting Procedures: WEAR SELF CONTAINED BREATHING APPARATUS & PROTECTIVE CLOTHING.

Unusal Fire/Explosion Hazard: EMITS TOXIC FUMES UNDER FIRE CONDITIONS.

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: EVACUATE AREA. WEAR PROTECTIVE EQUIPMENT. SWEEP UP, PLACE IN A BAG & HOLD FOR WASTE DISPOSAL. VENTILATE AREA & WASH SPILL SITE AFTER MATERIAL PICKUP IS COMPLETE.
Neutralizing Agent: N/K

Waste Disposal Methods: DISSOLVE OR MIX THE MATERIAL W/A COMBUSTIBLE SOLVENT & BURN IN A CHEMICAL INCINERATOR EQUIPPED W/AN AFTERBURNER & SCRUBBER. OBSERVE ALL FEDERAL, STATE & LOCAL REGULATIONS.

==============================================================================
HANDLING AND STORAGE
==============================================================================
KEEP TIGHTLY CLOSED. STORE IN A COOL DRY PLACE.

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: WEAR APPROPRIATE NIOSH/MSHA APPROVED RESPIRATOR.
Ventilation: CHEMICAL FUME HOOD
Protective Gloves: CHEMICAL RESISTANT
Eye Protection: SAFETY GOGGLES
Other Equipment: PROTECTIVE CLOTHING, SAFETY SHOWER & EYE BATH, RUBBER BOOTS.
Work Hygenic Practices: PROTECTIVE CLOTHING, SAFETY SHOWER & EYE BATH, RUBBER BOOTS.
Supplemental Safety & Health: N/K

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
Boiling Point: 
N/K
Melting/Freezing Point: 
205C
Decomposition Temp: 
N/K
Vapor Pressure: N/K Vapor Density: N/K
Specific Gravity: N/K
PH: N/K
Viscosity: N/P
Evaporation Rate & Reference: N/K
Solubility in Water: N/K
Appearance and Odor: PURPLE POWDER
Percent Volatiles by Volume: N/K
Corrosion Rate: N/K

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: N/K
Materials to Avoid: STRONG OXIDIZING AGENTS
Hazardous Decomposition Products: CO, CO2, NITROGEN OXIDES
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: N/K

==============================================================================
TOXICOLOGICAL
==============================================================================
N/P

==============================================================================
ECOLOGICAL
==============================================================================
N/P

==============================================================================
DISPOSAL
==============================================================================
DISSOLVE OR MIX THE MATERIAL W/A COMBUSTIBLE SOLVENT & BURN IN A CHEMICAL INCINERATOR EQUIPPED W/AN AFTERBURNER & SCRUBBER. OBSERVE ALL FEDERAL, STATE & LOCAL REGULATIONS.

==============================================================================
TRANSPORTATION
==============================================================================
N/P

==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media