HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: YES
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO

Health Hazards Acute And Chronic: ABSORBED THROUGH SKIN. CAUSES EYE & SKIN IRRITATION. MATERIAL IS IRRITATING TO MUCOUS MEMBRANES & UPPER RESPIRATORY TRACT.

Explanation of Carcinogenicity: NONE

Signs and Symptoms of Overexposure: IRRITATION, ALLEGIC REACTIONS.

Medical Conditions Aggravated by Overexposure: ASTHMA

==============================================================================
FIRST AID
==============================================================================
INHALATION: REMOVE PERSON TO FRESH AIR. IF NOT BREATHING, GIVE CPR. IF BREATHING IS DIFFICULT, GIVE OXYGEN. EYES/SKIN: IMMEDIATELY FLUSH W/COPIOUS AMOUNTS OF WATER FOR 15 MINS.

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: N/K

Auto Ignition Temperature Text: 

Lower Limits: N/K Upper Limits: N/K

Extinguishing Media: WATER SPRAY, CO2, DRY CHEMICAL POWDER, ALCOHOL/POLYMER FOAM.

Fire Fighting Procedures: WEAR SCBA & PROTECTIVE CLOTHING TO PREVENT CONTACT W/SKIN & EYES.

Unusal Fire/Explosion Hazard: EMITS TOXIC FUMES UNDER FIRE CONDITIONS. TOXIC GASES: CO, CO2, NITROGEN OXIDES & HYDROGEN GAS.

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: EVACUATE AREA. WEAR SCBA & PROTECTIVE CLOTHING. SWEEP UP, PLACE IN BAG FOR WASTE DISPOSAL. AVOID RAISING DUST. VENTILATE & WASH AREA AFTER PICKUP.
Neutralizing Agent: N/K

Waste Disposal Methods: DISSOLVE/MIX THE MATERIAL W/COMBUSTIBLE SOLVENT & BURN IN A CHEMICAL INCINERATOR EQUIPPED W/AN AFTERBURNER & SCRUBBER. DISPOSE OF IAW/FEDERAL, STATE & LOCAL REGULATIONS.

==============================================================================
HANDLING AND STORAGE
==============================================================================
N/K

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: WEAR APPROPRIATE NIOSH/MSHA APPROVED RESPIRATOR.
Ventilation: USE ONLY IN A CHEMICAL FUME HOOD. DON'T BREATH DUST.
Protective Gloves: CHEMICAL RESISTANT, HEAVY RUBBER
Eye Protection: SAFETY GOGGLES
Other Equipment: RUBBER BOOTS
Work Hygenic Practices: RUBBER BOOTS
Supplemental Safety & Health: N/K

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
Boiling Point: 
N/K
Melting/Freezing Point: 
N/K
Decomposition Temp: 
N/K
Vapor Pressure: N/K Vapor Density: N/K
Specific Gravity: N/K
PH: N/K
Viscosity: N/P
Evaporation Rate & Reference: N/K
Solubility in Water: N/K
Appearance and Odor: OFF-WHITE CRYSTALLINE POWDER
Percent Volatiles by Volume: N/K
Corrosion Rate: N/K

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: N/K
Materials to Avoid: STRONG OXIDIZING AGENTS
Hazardous Decomposition Products: TOXIC FUMES OF CO & CO2, NITROGEN OXIDES & HYDROGEN CHLORIC GAS.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: N/K

==============================================================================
TOXICOLOGICAL
==============================================================================
N/P

==============================================================================
ECOLOGICAL
==============================================================================
N/P

==============================================================================
DISPOSAL
==============================================================================
DISSOLVE/MIX THE MATERIAL W/COMBUSTIBLE SOLVENT & BURN IN A CHEMICAL INCINERATOR EQUIPPED W/AN AFTERBURNER & SCRUBBER. DISPOSE OF IAW/FEDERAL, STATE & LOCAL REGULATIONS.

==============================================================================
TRANSPORTATION
==============================================================================
N/P

==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media