> Blulux Laboratories Pvt. Ltd.

CAS # 504-15-4 ORCINOL 99%

Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad - 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300 
Fax : + 91 129 4190333
E-mail: bluluxlab@gmail.com  Website : www.blulux.com


 

 

Section 1 - Chemical Product Identification

 

MSDS Name: Orcinol, 99%
Synonyms: Resorcinol, 5-methyl-; 1,3-Dihydroxy-5-methylbenzene; 3,5-Dihydroxytoluene; 5-Methyl-1,3-benzenediol; 5-Methylresorcin; 5-Methylresorcinol; Orcin; Orcinol 5-Methylresorcinol
 

Section 2 - Composition, Information on Ingredients

 

CAS#

Chemical Name

Percent

EINECS/ELINCS

504-15-4

Orcinol

99

207-984-2


Hazard Symbols:
None listed.
Risk Phrases:
None listed.

Section 3 - Hazards Identification

EMERGENCY OVERVIEW

Appearance: off-white crystals. Light sensitive. Air sensitive. Caution! May be harmful if swallowed. Causes eye and skin irritation. Causes respiratory tract irritation. May cause digestive tract irritation.
Target Organs: None known.

Potential Health Effects
Eye: Causes eye irritation. May cause eye injury.
Skin: Causes skin irritation.
Ingestion: May cause irritation of the digestive tract. May be harmful if swallowed. Ingestion may cause convulsions, seizures and possible coma.
Inhalation: Causes respiratory tract irritation. Causes irritation of the mucous membrane.
Chronic: No information found.

Section 4 - First Aid Measures

Eyes: Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Get medical aid.
Skin: Get medical aid if irritation develops or persists. Wash clothing before reuse. Flush skin with plenty of soap and water.
Ingestion: Call a poison control center. If swallowed, do not induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Get medical aid.
Inhalation: Remove from exposure and move to fresh air immediately. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical aid if cough or other symptoms appear.
Notes to Physician: Treat symptomatically and supportively.

Section 5 - Fire Fighting Measures

General Information: As in any fire, wear a self-contained breathing apparatus in pressure-demand, MSHA/NIOSH (approved or equivalent), and full protective gear. During a fire, irritating and highly toxic gases may be generated by thermal decomposition or combustion.
Extinguishing Media: Use extinguishing media most appropriate for the surrounding fire. Use water spray, dry chemical, carbon dioxide, or chemical foam.
Flash Point: Not applicable.
Autoignition Temperature: Not applicable.
Explosion Limits, Lower:Not available.
Upper: Not available.
NFPA Rating: (estimated) Health: 1; Flammability: 0; Instability: 0

Section 6 - Accidental Release Measures

General Information: Use proper personal protective equipment as indicated in Section 8.
Spills/Leaks: Clean up spills immediately, observing precautions in the Protective Equipment section. Sweep up or absorb material, then place into a suitable clean, dry, closed container for disposal. Avoid generating dusty conditions. Provide ventilation. Place under an inert atmosphere.

Section 7 - Handling and Storage

Handling: Wash thoroughly after handling. Remove contaminated clothing and wash before reuse. Use with adequate ventilation. Minimize dust generation and accumulation. Avoid contact with eyes, skin, and clothing. Avoid ingestion and inhalation. Store protected from light. Handle under an inert atmosphere. Store protected from air.
Storage: Store in a tightly closed container. Store in a cool, dry, well-ventilated area away from incompatible substances. Store protected from light and air. Store under an inert atmosphere.

Section 8 - Exposure Controls, Personal Protection

Engineering Controls: Facilities storing or utilizing this material should be equipped with an eyewash facility and a safety shower. Use adequate ventilation to keep airborne concentrations low.
Exposure Limits

Chemical Name

ACGIH

NIOSH

OSHA - Final PELs

Orcinol

none listed

none listed

none listed


OSHA Vacated PELs: Orcinol: No OSHA Vacated PELs are listed for this chemical.
Personal Protective Equipment
Eyes: Wear appropriate protective eyeglasses or chemical safety goggles as described by OSHA's eye and face protection regulations in 29 CFR 1910.133 or European Standard EN166.
Skin: Wear appropriate protective gloves to prevent skin exposure.
Clothing: Wear appropriate protective clothing to prevent skin exposure.
Respirators: A respiratory protection program that meets OSHA's 29 CFR 1910.134 and ANSI Z88.2 requirements or European Standard EN 149 must be followed whenever workplace conditions warrant a respirator's use.

Section 9 - Physical and Chemical Properties

Physical State: Crystals
Appearance: off-white
Odor: Not available.
pH: Not available.
Vapor Pressure: Not available.
Vapor Density: Not available.
Evaporation Rate: Not available.
Viscosity: Not available.
Boiling Point: 287-290 deg C
Freezing/Melting Point:109-111 deg C
Decomposition Temperature: Not available.
Solubility: Soluble.
Specific Gravity/Density:1.290
Molecular Formula:C7H8O2
Molecular Weight:124.14

Section 10 - Stability and Reactivity

Chemical Stability: Stable under normal temperatures and pressures. Substance may discolor on exposure to light.
Conditions to Avoid: Incompatible materials, light, dust generation, exposure to air.
Incompatibilities with Other Materials: Air, strong oxidizing agents, acid chlorides, acid anhydrides.
Hazardous Decomposition Products: Carbon monoxide, irritating and toxic fumes and gases, carbon dioxide.
Hazardous Polymerization: Will not occur.

Section 11 - Toxicological Information

RTECS#:
CAS# 504-15-4: VH2100000
LD50/LC50:
CAS# 504-15-4:
Oral, mouse: LD50 = 772 mg/kg;
Oral, rabbit: LD50 = 2400 mg/kg;
Oral, rat: LD50 = 844 mg/kg;<BR.

Carcinogenicity:
CAS# 504-15-4: Not listed by ACGIH, IARC, NIOSH, NTP, or OSHA.
Epidemiology: No information available.
Teratogenicity: No information available.
Reproductive Effects: No information available.
Neurotoxicity: No information available.
Mutagenicity: No information available.
Other Studies: No data available.

Section 12 - Ecological Information

No information available.

Section 13 - Disposal Considerations

Chemical waste generators must determine whether a discarded chemical is classified as a hazardous waste. US EPA guidelines for the classification determination are listed in 40 CFR Parts 261.3. Additionally, waste generators must consult state and local hazardous waste regulations to ensure complete and accurate classification.
RCRA P-Series: None listed.
RCRA U-Series: None listed.

Section 14 - Transport Information

 

 

US DOT

IATA

RID/ADR

IMO

Canada TDG

Shipping Name:

No information available.

 

 

 

No information available.

Hazard Class:

 

 

 

 

 

UN Number:

 

 

 

 

 

Packing Group:

 

 

 

 

 

 

Section 15 - Regulatory Information

US FEDERAL

TSCA
CAS# 504-15-4 is listed on the TSCA inventory.
Health & Safety Reporting List
None of the chemicals are on the Health & Safety Reporting List.
Chemical Test Rules
None of the chemicals in this product are under a Chemical Test Rule.
Section 12b
None of the chemicals are listed under TSCA Section 12b.
TSCA Significant New Use Rule
None of the chemicals in this material have a SNUR under TSCA.
SARA

CERCLA Hazardous Substances and corresponding RQs
None of the chemicals in this material have an RQ.
SARA Section 302 Extremely Hazardous Substances
None of the chemicals in this product have a TPQ.
SARA Codes
CAS # 504-15-4: acute.
Section 313
No chemicals are reportable under Section 313.
Clean Air Act:
This material does not contain any hazardous air pollutants. This material does not contain any Class 1 Ozone depletors. This material does not contain any Class 2 Ozone depletors.
Clean Water Act:
None of the chemicals in this product are listed as Hazardous Substances under the CWA. None of the chemicals in this product are listed as Priority Pollutants under the CWA. None of the chemicals in this product are listed as Toxic Pollutants under the CWA.
OSHA:
None of the chemicals in this product are considered highly hazardous by OSHA.
STATE
CAS# 504-15-4 is not present on state lists from CA, PA, MN, MA, FL, or NJ.
California No Significant Risk Level: None of the chemicals in this product are listed.

European/International Regulations

European Labeling in Accordance with EC Directives
Hazard Symbols:
Not available.
Risk Phrases:
Safety Phrases:


WGK (Water Danger/Protection)

CAS# 504-15-4: No information available.
Canada - DSL/NDSL
CAS# 504-15-4 is listed on Canada's DSL List.
Canada - WHMIS
This product has a WHMIS classification of D2B.
Canadian Ingredient Disclosure List
Exposure Limits

Section 16 - Additional Information

Prepared by: BLULUX LABORATORIES (P) LTD.

For questions contact: Blulux Laboratories Pvt. Ltd.

79/66-B, I.H.I.Complex, Industrial Area, N.I.T. Faridabad, Haryana-121001

TEL: :++91-129-5021360, 2444433, 2237762  FAX:++ 91129-5027762 E-MAIL: blulux@rediffmail.com

 

The statements contained herein are offered for informational purposes only and are based upon technical data that Blulux Laboratories Pvt. Ltd. believes to be accurate. It is intended for use only by persons having the necessary technical skills and at their own discretion and risk. Since conditions and manner of use are outside our control, we make NO WARRANTY, EXPRESS OR IMPLIED, OF MERCHANTABILITY, FITNESS OR OTHERWISE.

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media