HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: YES
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO

Health Hazards Acute And Chronic: ACUTE-MAY BE CORROSIVE TO EYES AND SKIN. VERY TOXIC. OVEREXPOSURE CAUSES BURNS. CHRONIC- CUMULATIVE POISON.

Explanation of Carcinogenicity: N/P

Signs and Symptoms of Overexposure: SEE HEALTH HAZARDS SECTION.

Medical Conditions Aggravated by Overexposure: MAY AGGRAVATE ALLERGIES OR SENSITIVITY TO MERCURY; EYE OR SKIN CONDITIONS; DISORDERS OF THE CENTRAL NERVOUS SYSTEM OR KIDNEY.

==============================================================================
FIRST AID
==============================================================================
EYE AND SKIN CONTACT:IMMEDIATELY FLUSH WITH WATER FOR 15 MINUTES.REMOVE CONTAMINATED CLOTHING.CALL PHYSICIAN.INHALATION:REMOVE TO FRESH AIR.CALL PHYSICIAN.INGESTED:DO NOT INDUCE VOMITING.IF CONSCIOUS, DRINK 1-2 GLASSES OF WATER.CALL A PHYSI CIAN IMMEDIATELY.

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: NOT RELEVANT

Auto Ignition Temperature Text: 

Lower Limits: N/R Upper Limits: N/R

Extinguishing Media: MEDIA APPROPRIATE FOR SURROUNDING FIRE.

Fire Fighting Procedures: FIRE FIGHTERS SHOULD USE NIOSH APPROVED SELF CONTAIED BREATHING APPARATUS & FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE.

Unusal Fire/Explosion Hazard: FIRE OR EXCESSIVE HEAT MAY CAUSE PRODUCTION OF TOXIC FUMES.

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: DO NOT ALLOW THE MERCURY CONTAMINATE AIR OR WATER. SOAK UP SOLUTION WITH INERT MATERIAL. DO NOT BREATHE FUMES. DECONTAMINATE AREA WITH MERCURY ABSORBING COMPOUNDS AVAILABLE COMMERCIALLY.
Neutralizing Agent: NOT GIVEN

Waste Disposal Methods: DISPOSE OF ALL MERCURY CONTAMINATED MATERIAL IN AN EPA APPROVED HAZARDOUS WASTE FACILITY. DISPOSAL SHOULD BE MADE IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL ENVIRONMENTAL REGULATIONS.

==============================================================================
HANDLING AND STORAGE
==============================================================================
STORE TIGHTLY CLOSED.

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: USE NIOSH APPROVED AIR SUPPLIED RESPIRATOR IF NEEDED.
Ventilation: USE MECHANICAL (GENERAL) OR LOCAL EXHAUST VENTILATION TO MEET TLV REQUIREMENTS.
Protective Gloves: RUBBER GLOVES
Eye Protection: SAFETY GOGGLES WITH OPTIONAL FACE SHIELD
Other Equipment: EYE WASH STATION, SAFETY SHOWER, FUME HOOD, LAB GRADE GOGGLES, DISPOSABLE GLOVES, LAB COAT.
Work Hygenic Practices: EYE WASH STATION, SAFETY SHOWER, FUME HOOD, LAB GRADE GOGGLES, DISPOSABLE GLOVES, LAB COAT.
Supplemental Safety & Health: FORMULATION CHANGED. FOR PREVIOUS FORMULATION, SEE P/N A, SAME NSN.

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
HCC: B1
Boiling Point: 
UNKNOWN
Melting/Freezing Point: 
N/R
Decomposition Temp: 
UNKNOWN
Vapor Pressure: UNKNOWN Vapor Density: UNKNOWN
Specific Gravity: 1.265
PH: 12.1
Viscosity: N/P
Evaporation Rate & Reference: UNKNOWN
Solubility in Water: MISCIBLE
Appearance and Odor: CLEAR, LIGHT YELLOW LIQUID
Percent Volatiles by Volume: N/K
Corrosion Rate: 4.245

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: EXTREME TEMPERATURES AND LIGHT
Materials to Avoid: ACIDS, ORGANICS, AMMONIA, ALDEHYDES
Hazardous Decomposition Products: TOXIC FUMES OF MERCURY, IODINE AND IODINE COMPOUNDS
Hazardous Polymerization Products: N/P
Conditions to Avoid Polymerization: UNKNOWN

==============================================================================
TOXICOLOGICAL
==============================================================================
N/P

==============================================================================
ECOLOGICAL
==============================================================================
N/P

==============================================================================
DISPOSAL
==============================================================================
DISPOSE OF ALL MERCURY CONTAMINATED MATERIAL IN AN EPA APPROVED HAZARDOUS WASTE FACILITY. DISPOSAL SHOULD BE MADE IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL ENVIRONMENTAL REGULATIONS.

==============================================================================
TRANSPORTATION
==============================================================================
N/P

==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media