> Blulux Laboratories Pvt. Ltd.

CAS # 57 - 09 - 0 N - CETYL - N,N,N, TRIMETHYL AMMONIUM BROMIDE

Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad - 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300 
Fax : + 91 129 4190333
E-mail: bluluxlab@gmail.com  Website : www.blulux.com


 

1. Product Identification

Synonyms: Cetrimonium Bromide; Cetyltrimethylammonium bromide; Cetab; Centimide, HEXADECYLTRIMETHYLAMMONIUM BROMIDE

CAS No.: 57-09-0
Molecular Weight: 364.45
Chemical Formula: CH3(CH2)15N(CH3)3Br


2. Composition/Information on Ingredients

  Ingredient                                                CAS No         Percent        Hazardous                                  
  ---------------------------------------           ------------         ------------   ---------   
 
  Hexadecyltrimethylammonium Bromide        57-09-0            100%          Yes                                                                 
 

3. Hazards Identification

Emergency Overview
--------------------------
WARNING! HARMFUL IF SWALLOWED, INHALED OR ABSORBED THROUGH SKIN. CAUSES SEVERE IRRITATION TO EYES, SKIN AND RESPIRATORY TRACT.

Potential Health Effects
----------------------------------

Information on the human health effects from exposure to this substance is limited.

Inhalation:
Causes irritation to the respiratory tract. Symptoms may include coughing, shortness of breath.
Ingestion:
Toxic. Harmful if swallowed. Causes irritation to the gastrointestinal tract. Symptoms may include nausea, vomiting and diarrhea.
Skin Contact:
Causes irritation to skin. Symptoms include redness, itching, and pain. May be absorbed through the skin with possible systemic effects.
Eye Contact:
Causes irritation, redness, and pain.
Chronic Exposure:
No information found.
Aggravation of Pre-existing Conditions:
No information found.


4. First Aid Measures

Inhalation:
Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.
Ingestion:
Induce vomiting immediately as directed by medical personnel. Never give anything by mouth to an unconscious person. Get medical attention.
Skin Contact:
Immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Get medical attention. Wash clothing before reuse. Thoroughly clean shoes before reuse.
Eye Contact:
Immediately flush eyes with plenty of water for at least 15 minutes, lifting upper and lower eyelids occasionally. Get medical attention.
 


5. Fire Fighting Measures

Fire:
Flash point: 244C (471F) CC
Flammable limits in air % by volume:
lel: 0.4
Not considered to be a fire hazard. Gives off highly toxic and irritating fumes.
Explosion:
Not considered to be an explosion hazard.
Fire Extinguishing Media:
Use any means suitable for extinguishing surrounding fire.
Special Information:
In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full facepiece operated in the pressure demand or other positive pressure mode.


6. Accidental Release Measures

Ventilate area of leak or spill. Wear appropriate personal protective equipment as specified in Section 8. Spills: Sweep up and containerize for reclamation or disposal. Vacuuming or wet sweeping may be used to avoid dust dispersal.


 


7. Handling and Storage

Keep in a tightly closed container, stored in a cool, dry, ventilated area. Protect against physical damage. Isolate from incompatible substances. Containers of this material may be hazardous when empty since they retain product residues (dust, solids); observe all warnings and precautions listed for the product.


8. Exposure Controls/Personal Protection

Airborne Exposure Limits:
None established.
Ventilation System:
A system of local and/or general exhaust is recommended to keep employee exposures as low as possible. Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source, preventing dispersion of it into the general work area. Please refer to the ACGIH document, Industrial Ventilation, A Manual of Recommended Practices, most recent edition, for details.
Personal Respirators (NIOSH Approved):
For conditions of use where exposure to dust or mist is apparent and engineering controls are not feasible, a particulate respirator (NIOSH type N95 or better filters) may be worn. If oil particles (e.g. lubricants, cutting fluids, glycerine, etc.) are present, use a NIOSH type R or P filter. For emergencies or instances where the exposure levels are not known, use a full-face positive-pressure, air-supplied respirator. WARNING: Air-purifying respirators do not protect workers in oxygen-deficient atmospheres.
Skin Protection:
Wear impervious protective clothing, including boots, gloves, lab coat, apron or coveralls, as appropriate, to prevent skin contact.
Eye Protection:
Use chemical safety goggles and/or full face shield where dusting or splashing of solutions is possible. Maintain eye wash fountain and quick-drench facilities in work area.
 


9. Physical and Chemical Properties

Appearance:
White powder.
Odor:
No information found.
Solubility:
Soluble in water.
Specific Gravity:
No information found.
pH:
No information found.
% Volatiles by volume @ 21C (70F):
0
Boiling Point:
235C (455F)
Melting Point:
237 - 243C (459 - 469F)
Vapor Density (Air=1):
13
Vapor Pressure (mm Hg):
No information found.
Evaporation Rate (BuAc=1):
No information found.
 


10. Stability and Reactivity

Stability:
Stable under ordinary conditions of use and storage. Hygroscopic powder.
Hazardous Decomposition Products:
Nitrogen oxides, oxides of carbon as well as ionic or oxidized halogen.
Hazardous Polymerization:
Will not occur.
Incompatibilities:
Strong oxidizing agents.
Conditions to Avoid:
Incompatibles.


11. Toxicological Information


Oral rat LD50: 410 mg/Kg
Irritant, standard Draize, eye rabbit: 450 mg = severe

Investigated as a reproductive effector.
 

  --------\Cancer Lists\------------------------------------------------------
                                         ---NTP Carcinogen---
  Ingredient                             Known    Anticipated    IARC Category
  ------------------------------------   -----    -----------    -------------
  Hexadecyltrimethylammonium Bromide      No          No            None
  (57-09-0)

12. Ecological Information

Environmental Fate:
No information found.
Environmental Toxicity:
No information found.


13. Disposal Considerations

Whatever cannot be saved for recovery or recycling should be managed in an appropriate and approved waste disposal facility. Processing, use or contamination of this product may change the waste management options. State and local disposal regulations may differ from federal disposal regulations. Dispose of container and unused contents in accordance with federal, state and local requirements.


14. Transport Information

Not regulated.
 


15. Regulatory Information

  --------\Chemical Inventory Status - Part 1\---------------------------------
  Ingredient                                       TSCA  EC   Japan  Australia
  -----------------------------------------------  ----  ---  -----  ---------
  Hexadecyltrimethylammonium Bromide (57-09-0)      Yes  Yes   Yes      Yes                                      
 
  --------\Chemical Inventory Status - Part 2\---------------------------------
                                                          --Canada--
  Ingredient                                       Korea  DSL   NDSL  Phil.
  -----------------------------------------------  -----  ---   ----  -----
  Hexadecyltrimethylammonium Bromide (57-09-0)      Yes   Yes   No     Yes                         
 
  --------\Federal, State & International Regulations - Part 1\----------------
                                             -SARA 302-    ------SARA 313------
  Ingredient                                 RQ    TPQ     List  Chemical Catg.
  -----------------------------------------  ---   -----   ----  --------------
  Hexadecyltrimethylammonium Bromide         No    No      No         No
  (57-09-0)
 
  --------\Federal, State & International Regulations - Part 2\----------------
                                                        -RCRA-    -TSCA-
  Ingredient                                 CERCLA     261.33     8(d) 
  -----------------------------------------  ------     ------    ------
  Hexadecyltrimethylammonium Bromide         No         No         No              
  (57-09-0)
 
 
Chemical Weapons Convention:  No     TSCA 12(b):  No     CDTA:  No
SARA 311/312:  Acute: Yes      Chronic: No   Fire: No  Pressure: No
Reactivity: No          (Pure / Solid) 

Australian Hazchem Code: None allocated.
Poison Schedule: None allocated.
WHMIS:
This MSDS has been prepared according to the hazard criteria of the Controlled Products Regulations (CPR) and the MSDS contains all of the information required by the CPR.
 


16. Other Information

NFPA Ratings: Health: 2 Flammability: 0 Reactivity: 0
Label Hazard Warning:
WARNING! HARMFUL IF SWALLOWED, INHALED OR ABSORBED THROUGH SKIN. CAUSES SEVERE IRRITATION TO EYES, SKIN AND RESPIRATORY TRACT.
Label Precautions:
Avoid breathing dust.
Avoid contact with eyes, skin and clothing.
Wash thoroughly after handling.
Keep container closed.
Use only with adequate ventilation.
Label First Aid:
In case of contact, immediately flush eyes or skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Wash clothing before reuse. If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. If swallowed, induce vomiting immediately as directed by medical personnel. Never give anything by mouth to an unconscious person. In all cases, get medical attention.
Product Use:
Laboratory Reagent.
 

Prepared by: BLULUX LABORATORIES (P) LTD.

For questions contact: Blulux Laboratories Pvt. Ltd.

79/66-B, I.H.I.Complex, Industrial Area, N.I.T. Faridabad, Haryana-121001

TEL: :++91-129-5021360, 2444433, 2237762  FAX:++ 91129-5027762 E-MAIL: blulux@rediffmail.com

 

The statements contained herein are offered for informational purposes only and are based upon technical data that Blulux Laboratories Pvt. Ltd.  believes to be accurate. It is intended for use only by persons having the necessary technical skills and at their own discretion and risk. Since conditions and manner of use are outside our control, we make NO WARRANTY, EXPRESS OR IMPLIED, OF MERCHANTABILITY, FITNESS OR OTHERWISE.

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media