CAS # MOLYBDIC ACID 85% AR
|
|
Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad
- 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300
Fax
: + 91 129 4190333
E-mail: bluluxlab@gmail.com Website
: www.blulux.com
|
|

|
HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: NO Ingestion: YES
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO
Health Hazards Acute And Chronic: ACUTE:INHAL:IRRITATION OF UPPER RESPIRATORY
TRACT. SKIN/EYE CONTACT:IRRITATION. SKIN ABSORPTION:NONE IDENTIFIED.
INGEST:NONE IDENTIFIED. CHRONIC:NONE IDENTIFIED.
Explanation of Carcinogenicity: NOT RELEVANT
Signs and Symptoms of Overexposure: SEE HEALTH HAZARDS.
Medical Conditions Aggravated by Overexposure: NONE IDENTIFIED.
==============================================================================
FIRST AID
==============================================================================
INGEST:CALL MD. IF SWALLOWED, IF CONSCIOUS, IMMEDIATELY INDUCE VOMITING.
INHAL:REMOVE TO FRESH AIR. IF NOT BREATHING, GIVE ARTIFICIAL RESPIRATION. IF
BREATHING IS DIFFICULT, GIVE OXYGEN. SKIN:FLUSH W/WATER. EYE:IMMEDIATELY FLUSH
W/PLENTY OF WATER FOR AT LEAST 15 MINUTES.
==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: NOT APPLICABLE
Auto Ignition Temperature Text:
Lower Limits: N/A Upper Limits: N/A
Extinguishing Media: USE EXTINGUISHING MEDIA APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures: USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT (FP N).
Unusal Fire/Explosion Hazard: NONE IDENTIFIED.
==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: WEAR NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
CLOTHING. WITH CLEAN SHOVEL, CAREFULLY PLACE MATERIAL INTO CLEAN, DRY CONTAINER
& COVER; REMOVE FROM AREA. FLUSH SPILL AREA W/WATER.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSE I/A/W ALL APPLICABLE FEDERAL, STATE & LOCAL
ENVIRONMENTAL REGULATIONS.
==============================================================================
HANDLING AND STORAGE
==============================================================================
KEEP CONTAINER TIGHTLY CLOSED. SUITABLE FOR ANY GENERAL CHEMICAL STORAGE AREA.
==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: RESPIRATORY PROTECTION REQUIRED IF AIRBORNE
CONCENTRATION EXCEEDS TLV. AT CONCENTRATIONS UP TO 100 PPM, A NIOSH/MSHA
APPROVED DUST/MIST RESPIRATOR IS RECOMMENDED. ABOVE THIS LEVEL, A NIOSH/MSHA
APPROVED SCBA IS ADVISED.
Ventilation: USE GENERAL OR LOCAL EXHAUST VENTILATION TO MEET TLV REQUIREMENTS.
VENT HOOD.
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS (FP N).
Other Equipment: LAB COAT. WHEN HANDLING LIQUID PRODUCTS, SECONDARY PROTECTIVE
CONTAINERS MUST BE USED FOR CARRYING.
Work Hygenic Practices: LAB COAT. WHEN HANDLING LIQUID PRODUCTS, SECONDARY
PROTECTIVE CONTAINERS MUST BE USED FOR CARRYING.
Supplemental Safety & Health: NONE SPECIFIED BY MANUFACTURER.
==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
Boiling Point:
N/A
Melting/Freezing Point:
N/A
Decomposition Temp:
N/K
Vapor Pressure: N/A Vapor Density: N/A
Specific Gravity: 3.11 (H*2O=1)
PH: N/A
Viscosity: N/P
Evaporation Rate & Reference: NOT APPLICABLE
Solubility in Water: SLIGHT (0.1-1%)
Appearance and Odor: WHITE TO LIGHT YELLOW POWDER; ODORLESS.
Percent Volatiles by Volume: 0
Corrosion Rate: N/K
==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: NONE DOCUMENTED.
Materials to Avoid: STRONG OXIDIZING AGENTS.
Hazardous Decomposition Products: NONE IDENTIFIED.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: NOT RELEVANT
==============================================================================
TOXICOLOGICAL
==============================================================================
N/P
==============================================================================
ECOLOGICAL
==============================================================================
N/P
==============================================================================
DISPOSAL
==============================================================================
DISPOSE I/A/W ALL APPLICABLE FEDERAL, STATE & LOCAL ENVIRONMENTAL
REGULATIONS.
==============================================================================
TRANSPORTATION
==============================================================================
N/P
==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N
==============================================================================
OTHER
==============================================================================
|
|
|
Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals,
Analytical Reagents & Dehydrated Culture Media
|
|
|
|

|
|