> Blulux Laboratories Pvt. Ltd.

CAS # 119-36-8 METHYL SALCYLATE for SYNTHESIS

Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad - 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300 
Fax : + 91 129 4190333
E-mail: bluluxlab@gmail.com  Website : www.blulux.com


 

HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: N/P Skin: N/P Ingestion: N/P
Carcinogenicity Inds - NTP: N/P IARC: N/P OSHA: N/P

Health Hazards Acute And Chronic: N/P

Explanation of Carcinogenicity: N/P

Signs and Symptoms of Overexposure: IRRITATING TO SKIN,EYE,RESPIRATORY TRACT;ABDOMINAL PAIN,VOMITING,MENTAL DISTURBANCE.

Medical Conditions Aggravated by Overexposure: N/P

==============================================================================
FIRST AID
==============================================================================
SKIN:WASH W.SOAP & H*2O EYES:FLUSH W. H*2O. INGESTED:GIVE 2 GLASSES H*2O; INDUCE VOMITING.CALL A PHYSICIAN. INHALE:REMOVE TO FRESH AIR. GIVE CPR/OXYGEN IF NEED. KEEP WARM & QUIET. REMOVE CONTAMINATED CLOTHING. IF UNCONS DO NOT TAKE ANYTHING BY MOUTH.

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: 214F/101C

Auto Ignition Temperature Text: 

Lower Limits: N/K Upper Limits: N/K

Extinguishing Media: CO*2, FOAM, DRY CHEM.

Fire Fighting Procedures: WEAR CHEMICAL PROTECTIVE SUIT WITH SELF CONTD BRTHG APP.

Unusal Fire/Explosion Hazard: NONE

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: PICK UP & PLACE IN A SUITABLE CONTAINER FOR RECLAMATION OR DISPOSAL IN A METHOD THAT DOES NOT GENERATE DUST.
Neutralizing Agent: N/P

Waste Disposal Methods: WHATEVER CANNOT BE SAVED FOR RECLAMATION MAY BE DISPOSED IN A RCRA APPROVED HAZARDOUS WASTE FACILITY.

==============================================================================
HANDLING AND STORAGE
==============================================================================
STORE IN COOL,DRY WELL VENTED,LOW FIRE RISK AREA. PROTECT FR HEAT,SHOCK KEEP CONTAINERS CLOSED.

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: USE HALF-MASK CHEMICAL CARTRIDGE RESPIRATOR.
Ventilation: LOCAL EXHAUST.
Protective Gloves: IMPERVIOUS
Eye Protection: GOGGLES/FACE SHIELD
Other Equipment: SAFETY SHOWER & EYE BATH
Work Hygenic Practices: SAFETY SHOWER & EYE BATH
Supplemental Safety & Health: MSDS DATED 10-10-85.

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
HCC: N1
Boiling Point: 
432F/222C
Melting/Freezing Point: 
N/A
Decomposition Temp: 
N/A
Vapor Pressure: 1 Vapor Density: 5.24
Specific Gravity: 1.18
PH: N/P
Viscosity: N/P
Evaporation Rate & Reference: N/K
Solubility in Water: SOLUBLE
Appearance and Odor: CLEAR,PRACTICALLY COLORLESS LIQ.CHARACTERIST ODOR
Percent Volatiles by Volume: N/P
Corrosion Rate: N/P

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: NONE
Materials to Avoid: OXIDIZING MATERIAL.
Hazardous Decomposition Products: ACRID SMOKE & FUMES.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: N/P

==============================================================================
TOXICOLOGICAL
==============================================================================
N/P

==============================================================================
ECOLOGICAL
==============================================================================
N/P

==============================================================================
DISPOSAL
==============================================================================
WHATEVER CANNOT BE SAVED FOR RECLAMATION MAY BE DISPOSED IN A RCRA APPROVED HAZARDOUS WASTE FACILITY.

==============================================================================
TRANSPORTATION
==============================================================================
N/P

==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media