CAS # 119-36-8 METHYL SALCYLATE for SYNTHESIS
|
|
Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad
- 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300
Fax
: + 91 129 4190333
E-mail: bluluxlab@gmail.com Website
: www.blulux.com
|
|

|
HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: N/P Skin: N/P Ingestion: N/P
Carcinogenicity Inds - NTP: N/P IARC: N/P OSHA: N/P
Health Hazards Acute And Chronic: N/P
Explanation of Carcinogenicity: N/P
Signs and Symptoms of Overexposure: IRRITATING TO SKIN,EYE,RESPIRATORY
TRACT;ABDOMINAL PAIN,VOMITING,MENTAL DISTURBANCE.
Medical Conditions Aggravated by Overexposure: N/P
==============================================================================
FIRST AID
==============================================================================
SKIN:WASH W.SOAP & H*2O EYES:FLUSH W. H*2O. INGESTED:GIVE 2 GLASSES H*2O;
INDUCE VOMITING.CALL A PHYSICIAN. INHALE:REMOVE TO FRESH AIR. GIVE CPR/OXYGEN
IF NEED. KEEP WARM & QUIET. REMOVE CONTAMINATED CLOTHING. IF UNCONS DO NOT
TAKE ANYTHING BY MOUTH.
==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: 214F/101C
Auto Ignition Temperature Text:
Lower Limits: N/K Upper Limits: N/K
Extinguishing Media: CO*2, FOAM, DRY CHEM.
Fire Fighting Procedures: WEAR CHEMICAL PROTECTIVE SUIT WITH SELF CONTD BRTHG
APP.
Unusal Fire/Explosion Hazard: NONE
==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: PICK UP & PLACE IN A SUITABLE CONTAINER FOR
RECLAMATION OR DISPOSAL IN A METHOD THAT DOES NOT GENERATE DUST.
Neutralizing Agent: N/P
Waste Disposal Methods: WHATEVER CANNOT BE SAVED FOR RECLAMATION MAY BE
DISPOSED IN A RCRA APPROVED HAZARDOUS WASTE FACILITY.
==============================================================================
HANDLING AND STORAGE
==============================================================================
STORE IN COOL,DRY WELL VENTED,LOW FIRE RISK AREA. PROTECT FR HEAT,SHOCK KEEP
CONTAINERS CLOSED.
==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: USE HALF-MASK CHEMICAL CARTRIDGE RESPIRATOR.
Ventilation: LOCAL EXHAUST.
Protective Gloves: IMPERVIOUS
Eye Protection: GOGGLES/FACE SHIELD
Other Equipment: SAFETY SHOWER & EYE BATH
Work Hygenic Practices: SAFETY SHOWER & EYE BATH
Supplemental Safety & Health: MSDS DATED 10-10-85.
==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
HCC: N1
Boiling Point:
432F/222C
Melting/Freezing Point:
N/A
Decomposition Temp:
N/A
Vapor Pressure: 1 Vapor Density: 5.24
Specific Gravity: 1.18
PH: N/P
Viscosity: N/P
Evaporation Rate & Reference: N/K
Solubility in Water: SOLUBLE
Appearance and Odor: CLEAR,PRACTICALLY COLORLESS LIQ.CHARACTERIST ODOR
Percent Volatiles by Volume: N/P
Corrosion Rate: N/P
==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: NONE
Materials to Avoid: OXIDIZING MATERIAL.
Hazardous Decomposition Products: ACRID SMOKE & FUMES.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: N/P
==============================================================================
TOXICOLOGICAL
==============================================================================
N/P
==============================================================================
ECOLOGICAL
==============================================================================
N/P
==============================================================================
DISPOSAL
==============================================================================
WHATEVER CANNOT BE SAVED FOR RECLAMATION MAY BE DISPOSED IN A RCRA APPROVED
HAZARDOUS WASTE FACILITY.
==============================================================================
TRANSPORTATION
==============================================================================
N/P
==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================
|
|
|
Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals,
Analytical Reagents & Dehydrated Culture Media
|
|
|
|

|
|