> Blulux Laboratories Pvt. Ltd.

CAS # 10034-81-8 MAGNESIUM PERCHLORATE HYDRATE

Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad - 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300 
Fax : + 91 129 4190333
E-mail: bluluxlab@gmail.com  Website : www.blulux.com


 

HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: YES
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO

Health Hazards Acute And Chronic: ACUTE: INHALATION: DUST MAY CAUSE RESPIRATORY IRRITATION WITH COUGH AND SORE THROAT. SKIN CONTACT: MAY CAUSE IRRITATION WITH ERYTHEMA. EYE CONTACT: MAY CAUSE IRRITATION WITH PAIN, REDNESS, BLURRED VISION. CHRONIC: INHALATION: BLOOD PRESSURE FALL, CYANOSIS, HEADACHE, DIZZINESS. SKIN: DERMITITIS. EYE: CONJUNCTIVITIS.

Explanation of Carcinogenicity: N/P

Signs and Symptoms of Overexposure: VISUAL DISTURBANCE, MENTAL CONFUSION, DROWSINESS, DIZZINESS.

Medical Conditions Aggravated by Overexposure: PREVIOUS HISTORY OF SKIN OR RESPIRATORY PROBLEMS.

==============================================================================
FIRST AID
==============================================================================
INHALATION: REMOVE TO FRESH AIR. IF NOT BREATHING GIVE CPR; IF BREATHING DIFFICULT, GIVE OXYGEN. GET MEDICAL ATTENTION IMMEDIATELY. EYE: IMMEDIATELY FLUSH WITH PLENTY OF WATER. GET MEDICAL ATTENTION IMMEDIATELY. SKIN: WASH WITH SOAP AND WAT ER. REMOVE CONTAMINATED CLOTHING. GET MEDICAL ATTENTION IMMEDIATELY. INGESTION: INDUCE VOMIT. GIVE LARGE AMOUNTS OF WATER. GET MEDICAL ATTENTION IMMEDIATELY.

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: NONE

Auto Ignition Temperature Text: 

Lower Limits: N/R Upper Limits: N/R

Extinguishing Media: WATER ONLY. NO DRY CHEMICAL, CARBON DIOXIDE OR HALON

Fire Fighting Procedures: MOVE CONTAINERS FROM FIRE AREA IF POSSIBLE WITHOUT RISK. APPLY COOLING WATER TO SIDES OF CONTAINERS EXPOSED TO FLAMES UNTIL WELL AFTER FIRE IS OUT.

Unusal Fire/Explosion Hazard: OXIDIZERS DECOMPOSE, ESPECIALLY WHEN HEATED TO YIELD OXYGEN OR OTHER GASES WHICH WILL INCREASE THE BURNING RATE OF COMBUSTIBLE MATTER.

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: KEEP COMBUSTIBLES AWAY FROM SPILLED MATERIAL. DO NOT TOUCH SPILLED MATERIAL. FOR SMALL DRY SPILLS, WITH CLEAN SHOVEL PLACE MATERIAL INTO CLEAN, DRY CONTAINER AND COVER. FOR SMALL LIQUID SPILLS, TAKE UP WITH SAND, EARTH OR OTHER ABSORBENT.
Neutralizing Agent: N/P

Waste Disposal Methods: CONSULT YOUR LOCAL ENVIRONMENTAL OFFICER. DISPOSE OF ACCORDING TO FEDERAL, STATE AND LOCAL REGULATIONS.IMMEDIATELY REMOVE AND CAREFULLY DISPOSE OF ANY PERCHLORATE.

==============================================================================
HANDLING AND STORAGE
==============================================================================
PROTECT AGAINST PHYSICAL DAMAGE. STORE IN A DRY PLACE OF NONCOMBUSTIBLE CONSTRUCTION, SEPARATE FROM COMBUSTIBLE, ORGANIC, OXIDIZABLE MATERIAL.

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: HIGH LEVELS- SUPPLIED-AIR RESPIRATOR WITH FULL FACEPIECE, HELMIT, OR HOOD.
Ventilation: PROVIDE LOCAL EXHAUST VENTILATION SYSTEM.
Protective Gloves: IMPERVIOUS
Eye Protection: SAFETY GLASSES AND FACE SHIELD
Other Equipment: EYE WASH FOUNTAIN AND A QUICK DRENCH SHOWER.
Work Hygenic Practices: EYE WASH FOUNTAIN AND A QUICK DRENCH SHOWER.
Supplemental Safety & Health: N/P

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
HCC: D1
Boiling Point: 
N/R
Melting/Freezing Point: 
484F,251C
Decomposition Temp: 
N/A
Vapor Pressure: N/R Vapor Density: N/R
Specific Gravity: 2.2 @18C
PH: N/P
Viscosity: N/P
Evaporation Rate & Reference: N/R
Solubility in Water: APPRECIABLE
Appearance and Odor: WHITE HYGROSCOPIC CRYSTALS, GRANULAR OR FLAKY POWDER
Percent Volatiles by Volume: N/R
Corrosion Rate: N/P

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: AVOID CONTACT WITH COMBUSTIBLE MATERIALS (WOOD, PAPER, FUEL, OILS); IGNITION OR EXPLOSION MAY RESULT.
Materials to Avoid: MINERAL ACIDS, AMMONIA, BUTYL BENZENE, FLUORIDES, PHOSPHORUS, DIMETHYL SULFOXIDE, ETHYLENE OXIDE, ORGANIC MATERIALS
Hazardous Decomposition Products: MAY INCLUDE TOXIC AND HAZARDOUS FUMES OF CHLORIDES AND OXIDES OF MAGNESIUM.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: N/R

==============================================================================
TOXICOLOGICAL
==============================================================================
N/P

==============================================================================
ECOLOGICAL
==============================================================================
N/P

==============================================================================
DISPOSAL
==============================================================================
CONSULT YOUR LOCAL ENVIRONMENTAL OFFICER. DISPOSE OF ACCORDING TO FEDERAL, STATE AND LOCAL REGULATIONS.IMMEDIATELY REMOVE AND CAREFULLY DISPOSE OF ANY PERCHLORATE.

==============================================================================
TRANSPORTATION
==============================================================================
N/P

==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media