> Blulux Laboratories Pvt. Ltd.

CAS # 1309-48-4 MAGNESIUM OXIDE AR

Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad - 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300 
Fax : + 91 129 4190333
E-mail: bluluxlab@gmail.com  Website : www.blulux.com


 

HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: NO Ingestion: YES
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO

Health Hazards Acute And Chronic: INHALATION OF DUST MAY CAUSE IRRITATION TO UPPER RESPIRATORY TRACT. INHALATION OF FUMES MAY RESULT IN LEUKOCYTOSIS. CONTACT WITH SKIN OR EYES MAY CAUSE IRRITATION. TARGET ORGANS: RESPIRATORY SYSTEM, LUNGS, EYES.

Explanation of Carcinogenicity: NOT RELEVANT

Signs and Symptoms of Overexposure: SEE HEALTH HAZARDS.

Medical Conditions Aggravated by Overexposure: RESPIRATORY SYSTEM DISEASE.

==============================================================================
FIRST AID
==============================================================================
CALL A PHYSICIAN. INGEST: DO NOT INDUCE VOMITING; IF CONSCIOUS, GIVE LARGE AMOUNTS OF WATER. INHAL: REMOVE TO FRESH AIR. IF NOT BREATHING, GIVE ARTIFICIAL RESPIRATION. IF BREATHING IS DIFFICULT, GIVE OXYGEN. EYES: IMMEDIATELY FLUSH WITH PLE NTY OF WATER FOR AT LEAST 15 MIN. SKIN: FLUSH SKIN WITH WATER.

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: NOT APPLICABLE

Auto Ignition Temperature Text: 

Lower Limits: N/A Upper Limits: N/A

Extinguishing Media: USE EXTINGUISHING MEDIA APPROPRIATE FOR SURROUNDING FIRE.

Fire Fighting Procedures: WEAR NIOSH/MSHA APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT (FP N).

Unusal Fire/Explosion Hazard: NONE SPECIFIED BY MANUFACTURER.

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: WEAR NIOSH/MSHA APPROVED SCBA AND FULL PROTECTIVE CLOTHING. WITH CLEAN SHOVEL, CAREFULLY PLACE MATERIAL INTO CLEAN, DRY CONTAINER AND COVER; REMOVE FROM AREA. FLUSH SPILL AREA WITH WATER.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.

Waste Disposal Methods: DISPOSE IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL ENVIRONMENTAL REGULATIONS.

==============================================================================
HANDLING AND STORAGE
==============================================================================
KEEP CONTAINER TIGHTLY CLOSED. SUITABLE FOR ANY GENERAL CHEMICAL STORAGE AREA.

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: RESPIRATORY PROTECTION REQUIRED IF AIRBORNE CONCENTRATION EXCEEDS TLV. AT CONCENTRATIONS UP TO 500 PPM, A NIOSH/MSHA APPROVED HIGH-EFFECIENCY PARTICULATE RESPIRATOR IS RECOMMENDED. ABOVE THIS LEVEL, A NIOSH/MSHA APPROVED SCBA IS ADVISED.
Ventilation: USE GENERAL OR LOCAL EXHAUST VENTILATION TO MEET TLV REQUIREMENTS.
Protective Gloves: NEOPRENE GLOVES.
Eye Protection: CHEMICAL WORKERS GOGGLES (FP N).
Other Equipment: LAB COAT.
Work Hygenic Practices: LAB COAT.
Supplemental Safety & Health: NONE SPECIFIED BY MANUFACTURER.

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
HCC: N1
Boiling Point: 
6512F,3600C
Melting/Freezing Point: 
5166F,2852C
Decomposition Temp: 
N/K
Vapor Pressure: N/A Vapor Density: N/A
Specific Gravity: 3.60
PH: N/K
Viscosity: N/P
Evaporation Rate & Reference: NOT APPLICABLE
Solubility in Water: NEGLIGIBLE (<0.1%)
Appearance and Odor: WHITE TO LIGHT-GRAY POWDER. ODORLESS.
Percent Volatiles by Volume: 3
Corrosion Rate: N/K

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: AIR, DUSTING.
Materials to Avoid: STRONG ACIDS, BROMINE TRIFLUORIDE AND TRICHLORIDE, PHOSPHORUS PENTACHLORIDE.
Hazardous Decomposition Products: NONE IDENTIFIED.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: NOT RELEVANT

==============================================================================
TOXICOLOGICAL
==============================================================================
N/P

==============================================================================
ECOLOGICAL
==============================================================================
N/P

==============================================================================
DISPOSAL
==============================================================================
DISPOSE IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL ENVIRONMENTAL REGULATIONS.

==============================================================================
TRANSPORTATION
==============================================================================
N/P

==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media