HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: YES
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO

Health Hazards Acute And Chronic: INHALATION: IRRITATION OF MUCOUS MEMBRANES. INGESTION: NONE IDENTIFIED. SKIN CONTACT: IRRITATION; PROLONGED CONTACT MAY CAUSE DERMATITIS. EYE CONTACT: IRRITATION. CHRONIC: CENTRAL NERVOUS SYSTEM DEPRESSION.

Explanation of Carcinogenicity: NOT RELEVANT

Signs and Symptoms of Overexposure: SEE HEALTH HAZARDS.

Medical Conditions Aggravated by Overexposure: NO INFORMATION FOUND.

==============================================================================
FIRST AID
==============================================================================
INHAL: REMOVE TO FRESH AIR. IF NOT BREATHING, GIVE ARTIFICIAL RESPIRATION. IF BREATHING IS DIFFICULT, GIVE OXYGEN. PROMPT ACTION IS ESSENTIAL. INGEST: INDUCE VOMITING IMMEDIATELY AS DIRECTED BY MEDICAL PERSONNEL. NEVER GIVE ANYTHING BY MOUT H TO AN UNCONSCIOUS PERSON. GET MEDICAL ATTENTION. SKIN: FLUSH SKIN WITH WATER. EYES: IMMEDIATELY FLUSH WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES.

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: N/K

Auto Ignition Temperature Text: 

Lower Limits: N/K Upper Limits: N/K

Extinguishing Media: USE EXTINGUISHING MEDIA APPROPRIATE FOR SURROUNDING FIRE.

Fire Fighting Procedures: USE NIOSH APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT (FP N).

Unusal Fire/Explosion Hazard: NOT EXPECTED TO BE A FIRE HAZARD. EXPLOSION: NO INFORMATION FOUND.

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: WEAR NIOSH APPROVED SELF-CONTAINED BREATHING APPARATUS AND FULL PROTECTIVE CLOTHING. WITH CLEAN SHOVEL, CAREFULLY PLACE MATERIAL INTO CLEAN, DRY CONTAINER AND COVER. REMOVE FROM AREA. FLUSH SPILL AREA WITH WATER.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.

Waste Disposal Methods: WHATEVER CANNOT BE SAVED FOR RECOVERY/RECYCLING SHOULD BE MANAGED IN APPROP & APPRVD WASTE DISP FACILITY. PROCESSING, USE/CONTAM OF PROD MAY CHG WASTE MANAGEMENT OPTIONS. STATE & LOC DISP REGS MAY DIFFER FROM FED DISP REGS. DISP OF CNTNR & (SUPDAT)

==============================================================================
HANDLING AND STORAGE
==============================================================================
KEEP CONTAINER TIGHTLY CLOSED. SUITABLE FOR ANY GENERAL CHEMICAL STORAGE AREA.

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: FOR CNDTNS OF USE WHERE EXPOS TO SUBSTANCE IS APPARENT, CONSULT INDUS HYGIENIST. FOR EMERS OR INSTANCES WHERE EXPOS LEVELS ARE NOT KNOWN, USE NIOSH APPRVD FULL-FACEPIECE POS-PRESS, AIR-SUPPLIED RESP. WARNING: AIR PURIFYING RESPS DO (SUPDAT)
Ventilation: SYS OF LOC &/OR GEN EXHST RECOM TO KEEP EMPLOYEE EXPOS AS LOW AS POSS. LOC EXHST VENT GENERALLY PREF BECAUSE IT (SUPDAT)
Protective Gloves: IMPERVIOUS GLOVES,
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGLES (FP N).
Other Equipment: ANSI APPRVD EYE WASH & DELUGE SHOWER (FP N). WEAR IMPERVIOUS CLTHG, INCL BOOTS, LAB COAT, APRON OR COVERALLS, AS APPROP.
Work Hygenic Practices: ANSI APPRVD EYE WASH & DELUGE SHOWER (FP N). WEAR IMPERVIOUS CLTHG, INCL BOOTS, LAB COAT, APRON OR COVERALLS, AS APPROP.
Supplemental Safety & Health: WASTE DISP METH: UNUSED CONTENTS I/A/W FED, STATE & LOCAL REQS. RESP PROT: NOT PROTECT WORKERS IN OXYG-DEFICIENT ATMS. VENT: CAN CTL EMISSION OF CONTAMINANT AT ITS SOURCE, PREVENTING DISPERSION OF IT INTO GEN WORK AREA. REFER TO ACGIH DOCUM ENT, INDUS VENT, A MANNUAL OF RECOM PRACTS, MOST RECENT EDITION, FOR DETAILS.

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
Boiling Point: 
N/K
Melting/Freezing Point: 
207F,97C
Decomposition Temp: 
N/K
Vapor Pressure: N/A Vapor Density: N/A
Specific Gravity: 1.48
PH: N/K
Viscosity: N/P
Evaporation Rate & Reference: N/K
Solubility in Water: SLIGHT (0.1-1%)
Appearance and Odor: YELLOW TO TAN CRYSTALLINE SOLID.
Percent Volatiles by Volume: N/K
Corrosion Rate: N/K

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: NO INFORMATION FOUND.
Materials to Avoid: NO INFORMATION FOUND.
Hazardous Decomposition Products: NO INFORMATION FOUND.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: NOT RELEVANT

==============================================================================
TOXICOLOGICAL
==============================================================================
N/P

==============================================================================
ECOLOGICAL
==============================================================================
N/P

==============================================================================
DISPOSAL
==============================================================================
WHATEVER CANNOT BE SAVED FOR RECOVERY/RECYCLING SHOULD BE MANAGED IN APPROP & APPRVD WASTE DISP FACILITY. PROCESSING, USE/CONTAM OF PROD MAY CHG WASTE MANAGEMENT OPTIONS. STATE & LOC DISP REGS MAY DIFFER FROM FED DISP REGS. DISP OF CNTNR & (SUPDAT)

==============================================================================
TRANSPORTATION
==============================================================================
N/P

==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media