> Blulux Laboratories Pvt. Ltd.

CAS # 143-07-7 LAURIC ACID PURE

Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad - 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300 
Fax : + 91 129 4190333
E-mail: bluluxlab@gmail.com  Website : www.blulux.com


 

HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: YES
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO

Health Hazards Acute And Chronic: POISON. AN EXPERIMENTAL NEOPLASTIGEN. MUTAGENIC DATA.

Explanation of Carcinogenicity: NOT RELEVANT

Signs and Symptoms of Overexposure: UNKNOWN. MAY INCLUDE MODERATE TO SEVERE ERYTHEMA (REDNESS) & MODERATE EDEMA (RAISED SKIN).

Medical Conditions Aggravated by Overexposure: NONE SPECIFIED BY MANUFACTURER.

==============================================================================
FIRST AID
==============================================================================
SKIN:REMOVE CONTAM CLTHG & RINSE W/COPIOUS AMTS OF SOAP & WATER FOR CONSIDERABLE AMT OF TIME. CALL MD. INGEST:DRINK 1-2 GLASSES OF WATER W/IN 15 MINS. INDUCE VOMIT. ALWAYS CALL MD/TAKE PATIENT TO HOSPITAL. EYES:RINSE LIBERALLY W/WATER FOR A T LST 15 MINS. ALWAYS CALL MD/TAKE TO HOSPITAL. INHAL:TAKE PATIENT INTO FRESH AIR & ALLOW TO REST. ALWAYS CALL MD/TAKE PATIENT TO HOSPITAL.

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: >320F,>160C

Auto Ignition Temperature Text: 

Lower Limits: N/K Upper Limits: N/K

Extinguishing Media: CO*2, DRY CHEMICAL OR FOAM.

Fire Fighting Procedures: USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE EQUIPMENT (FP N).

Unusal Fire/Explosion Hazard: SLIGHT FLAMMABILITY.

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: SWEEP INTO SUITABLE CONTAINER FOR DISPOSAL.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.

Waste Disposal Methods: DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL REGULATIONS (FP N). INCINERATE OR LANDFILL AS COMPLIES W/STATE & LOCAL LAWS.

==============================================================================
HANDLING AND STORAGE
==============================================================================
OBSERVE PROPER LABORATORY PROCEDURES WHEN HANDLING MATERIAL. STORAGE: ROOM TEMPERATURE.

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: NIOSH/MSHA APPROVED RESPIRATORY PROTECTION.
Ventilation: LOCAL EXHAUST SYSTEM REQUIRED WHEN SUBSTANCE IS USED FOR ITS NORMAL PURPOSE. ALWAYS USE A HOOD.
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS (FP N).
Other Equipment: EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET ANSI DESIGN CRITERIA (FP N). ALWAYS WEAR MASK OR OTHER PROT CLOTHING.
Work Hygenic Practices: EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET ANSI DESIGN CRITERIA (FP N). ALWAYS WEAR MASK OR OTHER PROT CLOTHING.
Supplemental Safety & Health: NONE SPECIFIED BY MANUFACTURER.

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
Boiling Point: 
374F,190C
Melting/Freezing Point: 
>108F,>42C
Decomposition Temp: 
N/K
Vapor Pressure: 50 @ 210C Vapor Density: N/K
Specific Gravity: 0.89
PH: N/K
Viscosity: N/P
Evaporation Rate & Reference: N/K
Solubility in Water: INSOLUBLE
Appearance and Odor: OFF-WHITE SOLID.
Percent Volatiles by Volume: N/K
Corrosion Rate: N/K

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: NONE SPECIFIED BY MANUFACTURER.
Materials to Avoid: BASES, OXIDIZING AGENTS, REDUCING AGENTS.
Hazardous Decomposition Products: DECOMPOSITION OF SUBSTANCE WHEN HEATED OR BURNED: ACRID SMOKE & IRRITATING FUMES.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: NOT RELEVANT

==============================================================================
TOXICOLOGICAL
==============================================================================
N/P

==============================================================================
ECOLOGICAL
==============================================================================
N/P

==============================================================================
DISPOSAL
==============================================================================
DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL REGULATIONS (FP N). INCINERATE OR LANDFILL AS COMPLIES W/STATE & LOCAL LAWS.

==============================================================================
TRANSPORTATION
==============================================================================
N/P

==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media