HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: YES
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO

Health Hazards Acute And Chronic: CORR. ACUTE:INHAL:ING 1:SEV IRRIT OF MUC MEMBS, SPARKLING BEFORE EYES, SEV COUGH, HDCH, SOMNOLENCE & SWELL OF PAROTID GLAND, POSS PULM EDEMA, CATARRHAL RHINITIS, STOMATITIS, CHRONIC PHARYNGITIS, FEELING OF TIGHTNESS IN CHEST. ING 2:IRRIT TO UPPER RESP TRACT, COUGH, CHEST DISCOMFORT. SKIN:ING 1:BROWN (EFTS OF OVEREXP)

Explanation of Carcinogenicity: NOT RELEVANT

Signs and Symptoms of Overexposure: HLTH HAZ:DISCOLORATION W/MARKED ERYTHEMA, DESQUAMATION, VESICULATION W/WEEPING & CRUSTING, LESIONS (ACNEFORM & SLOW HEALING). ABSORP MAY OCCUR. DEATH (1/3 OF BODY SURF). HYPERSENS RXN (DERM, FEVER, GENERALIZED ERUPTION & POSS FATAL). ING 2: HYPERSENS (RASHES, RHINITIS, LARYNGEAL EDEMA, SERUM SICKNESS W/FEVER,(SUPP DATA)

Medical Conditions Aggravated by Overexposure: PERSONS W/IMPAIRED PULMONARY OR THYROID FUNCTION OR HISTORY OF ASTHMA, ALLERGIES OR KNOWN SENSITIZATION TO IODINE ARE AT INCREASED RISK FROM EXPOSURE.

==============================================================================
FIRST AID
==============================================================================
INGEST:CALL MD IMMEDIATELY (FP N). INHAL:REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O*2/ARTIFICIAL RESPIRATION) (FP N). EYES:IMMEDIATELY FLUSH W/POTABLE WATER FOR A MINIMUM OF 15 MINUTES. SEEK ASSISTANCE FROM MD (FP N). SKIN:FLUSH W/COPIO US AMOUNTS OF WATER. CALL MD (FP N). FOR MORE SPECIFIC INFORMATION REGARDING FIRST AID TREATMENT CONTACT NEHC (FP N).

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: NON-FLAMMABLE

Auto Ignition Temperature Text: 

Lower Limits: N/K Upper Limits: N/K

Extinguishing Media: DRY CHEMICAL, CARBON DIOXIDE, WATER SPRAY OR REGULAR FOAM. FOR LARGER FIRES, USE WATER SPRAY, FOG OR REGULAR FOAM.

Fire Fighting Procedures: USE NIOSH APPRVD SCBA & FULL PROT EQUIP(FP N). DO NOT TOUCH SPILLED MATL. EXTING USING AGENTS INDICATED. USE FLOODING AMTS OF WATER AS FOG. COOL CNTNRS (SUPDAT)

Unusal Fire/Explosion Hazard: NEGLIGIBLE FIRE HAZARD WHEN EXPOSED TO HEAT OR FLAME. AVOID BREATHING IRRITATING VAPORS; KEEP UPWIND.

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: OCCUPATIONAL SPILL:COVER W/SODA ASH. SCOOP UP & PLACE IN A SUITABLE CONTAINER.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.

Waste Disposal Methods: DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL REGULATIONS (FP N).

==============================================================================
HANDLING AND STORAGE
==============================================================================
AVOID ANY POSSIBILITY OF SKIN CONTACT W/LIQUIDS CONTAINING >7% IODINE, & REPEATED OR PROLONGED SKIN CONTACT W/LIQUIDS CONTAINING 7% OR LESS.

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: NIOSH APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN (FP N). FOR MORE SPECIFIC INFORMATION CONTACT NEHC (FP N).
Ventilation: PROVIDE LOCAL EXHAUST OR GENERAL DILUTION VENTILATION SYSTEM.
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGS &(SUPDAT)
Other Equipment: EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET ANSI DESIGN CRITERIA (FP N). WEAR IMPERVIOUS CLOTHING.
Work Hygenic Practices: EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET ANSI DESIGN CRITERIA (FP N). WEAR IMPERVIOUS CLOTHING.
Supplemental Safety & Health: FIRE FIGHT PROC:W/FLOODING AMTS OF WATER. USE WATER TO ABSORB VAPS. EYE PROT:FULL LGTH FCSHLD (FP N). EFTS OF OVEREXP:JOINT PAIN, SWELL & LYMPH NODE ENLARGEMENT. EYE:ING 1:IRRIT, BROWN STAINING OF CORNEAL EPITHELIUM, LOSS OF LAYER TISS W/RE COVERY, BURNING SENSATION, LACRIM, BLEPHARITIS. ING 2:CONJ. INGEST:ING 1:(ING 4)

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
Boiling Point: 
212F,100C
Melting/Freezing Point: 
32.0F,0.0C
Decomposition Temp: 
N/K
Vapor Pressure: SEE ING 3 Vapor Density: SEE ING 3
Specific Gravity: 1
PH: N/K
Viscosity: N/P
Evaporation Rate & Reference: >1 (ETHER=1)
Solubility in Water: SOLUBLE
Appearance and Odor: DEEP AMBER LIQUID.
Percent Volatiles by Volume: N/K
Corrosion Rate: N/K

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: STABLE UNDER NORMAL TEMPERATURES & PRESSURES.
Materials to Avoid: METALS & ALLOYS, STRONG OXIDANTS, ALKALI METALS & METALLIC SALTS. FOR COMPLETE LIST OF MATLS TO AVOID CONT NEHC (FP N).
Hazardous Decomposition Products: THERMAL DECOMPOSITION PRODUCTS MAY INCLUDE VERY TOXIC POTASSIUM OXIDE, IODINE & HYDROGEN IODIDE.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: NOT RELEVANT

==============================================================================
TOXICOLOGICAL
==============================================================================
N/P

==============================================================================
ECOLOGICAL
==============================================================================
N/P

==============================================================================
DISPOSAL
==============================================================================
DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL REGULATIONS (FP N).

==============================================================================
TRANSPORTATION
==============================================================================
N/P

==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media