> Blulux Laboratories Pvt. Ltd.

CAS # 7782-68-5 IODIC ACID AR

Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad - 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300 
Fax : + 91 129 4190333
E-mail: bluluxlab@gmail.com  Website : www.blulux.com


 

HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: YES
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO

Health Hazards Acute And Chronic: CORROSIVE. ACUTE: INHAL:ACID FUMES MAY CAUSE SEV MUC MEMB IRRIT, COUGH, CHOKING, DYSPNEA, HDCH, DIZZ & WEAK. DELAYED SYMPS MAY INCL PULM EDEMA, CHEST TIGHTNESS, FROTHY SPUTUM, CYANOSIS, RALES & HYPOTENSION. SKIN:CNTCT W/ACIDS MAY CAUSE SEV IRRIT & PAIN W/BURNS, VESICULATION & BROWNISH/YELLOWISH STAINS.(EFTS OF OVEREXP)

Explanation of Carcinogenicity: NOT RELEVANT

Signs and Symptoms of Overexposure: HLTH HAZ: EYES:LIQ/FUMES OF ACIDS MAY CAUSE CORNEAL & CONJ EDEMA, IRITIS, CORNEAL EROSION & OPACITY, PAIN, LACRIM, BLURRED VISION & PHOTOPHOBIA. INGEST:ACIDS MAY CAUSE SEV BURNING PAIN IN MOUTH, THROAT & ABDOMEN FOLLOWED BY NAUS, VOMIT, HEM ATEMESIS, DIARR, BLOODY STOOLS, HEMATURIA, ALBUMINURIA & POSS ASPHYXIA. (ING 4)

Medical Conditions Aggravated by Overexposure: NONE SPECIFIED BY MANUFACTURER.

==============================================================================
FIRST AID
==============================================================================
INHAL:REMOVE TO FRESH AIR IMMED. IF BRTHG STOPS, GIVE ARTF RESP. MAINTAIN AIRWAY & BLOOD PRESS & ADMIN O*2 IF AVAIL. KEEP WARM & AT REST. TREAT SYMP & SUPPORTIVELY. ADMIN OF OXYGEN SHOULD BE PERFORMED BY QUALIFIED PERS. GET MED ATTN. SKIN:R EMOVE CONTAMD CLTHG & SHOES IMMED. WASH AFFECTED AREA W/SOAP OR MILD DETERGENT & LG AMTS OF WATER UNTIL NO EVID OF CHEM REMAINS (AT LST 15-20 MIN). IN (ING 9)

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: N/K

Auto Ignition Temperature Text: 

Lower Limits: N/K Upper Limits: N/K

Extinguishing Media: WATER ONLY, NO DRY CHEMICAL, CARBON DIOXIDE OR HALON. FOR LARGER FIRES, FLOOD AREA WITH WATER FROM A DISTANCE.

Fire Fighting Procedures: NIOSH APPROVED SCBA & FULL PROT EQUIP (FP N). MOVE CNTNR FROM FIRE AREA IF W/OUT RISK. APPLY COOLING WATER TO SIDES OF CNTNRS EXPOS TO FLAMES UNTIL WELL(SUPDAT)

Unusal Fire/Explosion Hazard: NEGLIG FIRE HAZ WHEN EXPOS TO HEAT/FLAME. OXIDIZERS DECOMPOSE, ESP WHEN HEATED TO YIELD OXYGEN/OTHER GASES WHICH WILL INCR BURNING RATE OF COMBUST (ING 2)

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: KEEP COMBUSTS (WOOD, PAPER, OIL, ETC) AWAY FROM SPILLED MATL. DO NOT TOUCH SPILLED MATL. SM DRY SPILLS:W/CLEAN SHOVEL PLACE MATL INTO CLEAN, DRY CNTNR & COVER; MOVE CNTNRS FROM SPILL AREA. SM LIQ SPILLS:TAKE UP W/SAND, EARTH/OTHER ABSORB (I NG 16)
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.

Waste Disposal Methods: DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS (FP N). DISPOSAL MUST BE IN ACCORDANCE WITH STANDARDS APPLICABLE TO GENERATORS OF HAZARDOUS WASTE, 40 CFR 262. EPA HAZARDOUS WASTE NUMBER D001. 100 LB CERCLA SECTION 1 03 RQ.

==============================================================================
HANDLING AND STORAGE
==============================================================================
CONSULT NFPA PUBLICATION 43A, STORAGE OF LIQUID AND SOLID OXIDIZING MATERIALS, FOR STORAGE REQUIREMENTS. STORE AWAY FROM INCOMPATIBLE SUBSTANCES.

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: FOLLOWING RESPS ARE RECD BASED ON INFO FOUND IN PHYSICAL DATA, TOX & HLTH EFTS SECTIONS. THEY ARE RANKED FROM MINIMUM TO MAX RESP PROT. RESP SELECTION MUST BE BASED ON CONTAM LEVELS FOUND IN WORKPLACE, SPECIFIC OPERATION, MUST NOT (ING 18)
Ventilation: PROVIDE LOCAL EXHAUST OR PROCESS ENCLOSURE VENTILATION SYSTEM.
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGS (ING 23)
Other Equipment: ANSI APPRVD EYE WASH & DELUGE SHOWER (FP N). WEAR APPROP PROTECTIVE (IMPERVIOUS) CLTHG & EQUIP TO PVNT POSS SKIN CNTCT.
Work Hygenic Practices: ANSI APPRVD EYE WASH & DELUGE SHOWER (FP N). WEAR APPROP PROTECTIVE (IMPERVIOUS) CLTHG & EQUIP TO PVNT POSS SKIN CNTCT.
Supplemental Safety & Health: FIRE FIGHT PROC:AFTER FIRE IS OUT. FOR MASSIVE FIRES IN CARGO AREA, USE UNMANNED HOSE HOLDER/MONITOR NOZZS; IF IMPOSS, W/DRAW FROM AREA & LET FIRE BURN. FLOOD W/WATER. COOL CNTNRS W/FLOODING AMTS OF WATER FROM AS FAR A DIST AS POSS. AVOID B RTHG VAPS/DUSTS. EVACUATE TO RADIUS OF 2500 FEET FOR UNCONTROLLABLE FIRE.

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
Boiling Point: 
DECOMPOSES
Melting/Freezing Point: 
230F,110C
Decomposition Temp: 
N/K
Vapor Pressure: N/K Vapor Density: N/K
Specific Gravity: 5.0 @ 0C
PH: ACIDIC
Viscosity: N/P
Evaporation Rate & Reference: N/K
Solubility in Water: SOLUBLE
Appearance and Odor: COLORLESS OR PALE YELLOW CRYSTALS.
Percent Volatiles by Volume: N/K
Corrosion Rate: N/K

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: NONE SPECIFIED BY MANUFACTURER.
Materials to Avoid: BORON: VIGOROUS RXN FORMING INCANDESCANT MASS BELOW 40C. GRAPHITE GASKETS, PACKINGS & LUBRICANTS: REACTS. (ING 3)
Hazardous Decomposition Products: THERMAL DECOMPOSITION PRODUCTS MAY INCLUDE TOXIC AND CORROSIVE FUMES OF IODIDES.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: NOT RELEVANT

==============================================================================
TOXICOLOGICAL
==============================================================================
N/P

==============================================================================
ECOLOGICAL
==============================================================================
N/P

==============================================================================
DISPOSAL
==============================================================================
DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS (FP N). DISPOSAL MUST BE IN ACCORDANCE WITH STANDARDS APPLICABLE TO GENERATORS OF HAZARDOUS WASTE, 40 CFR 262. EPA HAZARDOUS WASTE NUMBER D001. 100 LB CERCLA SECTION 1 03 RQ.

==============================================================================
TRANSPORTATION
==============================================================================
N/P

==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media