HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: YES
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO

Health Hazards Acute And Chronic: ACUTE- HARMFUL IF SWALLOWED, INHALED, OR ABSORBED THROUGH SKIN. MATERIAL IS SEVERELY IRRITATING TO MUCUS MEMBRANES, UPPER RESPIRATORY TRACT, EYES AND SKIN. MAY CAUSE NERVOUS SYSTEM DISTURBANCES. TARGET ORGANS: BONE MARROW AND NERVES.

Explanation of Carcinogenicity: NONE

Signs and Symptoms of Overexposure: BURNING SENSATION, COUGHING, WHEEZING, LARYRINGITIS, SHORTNESS OF BREATH, HEADACHE, NAUSEA AND VOMITING.

Medical Conditions Aggravated by Overexposure: NONE LISTED BY MFR.

==============================================================================
FIRST AID
==============================================================================
INHALATION:REMOVE TO FRESH AIR, PROVIDE CPR/OXYGEN IF NEEDED. EYE CONTACT:FLUSH WITH WATER FOR 15 MINUTES. GET MEDICAL HELP. SKIN CONTACT:WASH WITH SOAP AND WATER. GET MED ATTENTION IF SYMPTOMS PERSIST. INGESTION: DRINK 1-2 GLASSES OF WATER . GET MEDICAL HELP IMMEDIATELY.

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: N/R

Auto Ignition Temperature Text: 

Lower Limits: N/K Upper Limits: N/K

Extinguishing Media: WATER SPRAY, CO2, DRY CHEMICAL POWDER, ALCOHOL OR POLYMER FOAM.

Fire Fighting Procedures: FIRE FIGHTERS SHOULD WEAR PROTECTIVE CLOTHING AND SELF-CONTAINED BREATHING APPARATUS.

Unusal Fire/Explosion Hazard: EMITS TOXIC FUMES UNDER FIRE CONDITIONS.

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: WEAR PROTECTIVE EQUIPMENT. SWEEP UP OR VACUUM, PLACE IN A BAG & HOLD FOR WASTE DISPOSAL. AVOID RAISING DUST. VENTILATE AREA & WASH SPILL SITE AFTER MATERIAL PICKUP IS COMPLETE.
Neutralizing Agent: N/K

Waste Disposal Methods: DISSOLVE OR MIX THE MATERIAL WITH A COMBUSTIBLE SOLVENT & BURN IN A CHEMICAL INCINERATOR EQUIPPED WITH AN AFTERBURNER & SCRUBBER. OBSERVE ALL FEDERAL, STATE & LOCAL LAWS CONCERNING HEALTH & POLLUTION.

==============================================================================
HANDLING AND STORAGE
==============================================================================
KEEP TIGHTLY CLOSED. HYGROSCOPIC. STORE IN A COOL DRY PLACE.

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: USE APPROPRIATE NIOSH/MSHA APPROVED RESPIRATOR
Ventilation: CHEMICAL FUME HOOD
Protective Gloves: CHEMICAL RESISTANT
Eye Protection: SAFETY GOGGLES, FACESHIELD (8-INCH MIN)
Other Equipment: SAFETY SHOWER & EYEBATH
Work Hygenic Practices: SAFETY SHOWER & EYEBATH
Supplemental Safety & Health: N/K

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
HCC: N1
Boiling Point: 
N/K
Melting/Freezing Point: 
356F,180C
Decomposition Temp: 
N/K
Vapor Pressure: N/K Vapor Density: N/K
Specific Gravity: N/K
PH: N/K
Viscosity: N/P
Evaporation Rate & Reference: N/K
Solubility in Water: N/K
Appearance and Odor: WHITE CRYSTALLINE POWDER
Percent Volatiles by Volume: N/K
Corrosion Rate: N/K

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: MOISTURE
Materials to Avoid: STRONG OXIDIZERS
Hazardous Decomposition Products: CO, CO2, NITROGEN OXIDES, HYDROGEN CHLORIDE GAS
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: N/K

==============================================================================
TOXICOLOGICAL
==============================================================================
N/P

==============================================================================
ECOLOGICAL
==============================================================================
N/P

==============================================================================
DISPOSAL
==============================================================================
DISSOLVE OR MIX THE MATERIAL WITH A COMBUSTIBLE SOLVENT & BURN IN A CHEMICAL INCINERATOR EQUIPPED WITH AN AFTERBURNER & SCRUBBER. OBSERVE ALL FEDERAL, STATE & LOCAL LAWS CONCERNING HEALTH & POLLUTION.

==============================================================================
TRANSPORTATION
==============================================================================
N/P

==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media