> Blulux Laboratories Pvt. Ltd.

CAS #  GRAM'S IODINE 

Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad - 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300 
Fax : + 91 129 4190333
E-mail: bluluxlab@gmail.com  Website : www.blulux.com


 

HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: YES
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO

Health Hazards Acute And Chronic: EYES- MAY CAUSE IRRITATION. SKIN- MAY CAUSE IRRITATION. INGESTION- MAY CAUSE GASTROINTESTINAL DISCOMFORT. INHALATION- MAY CAUSE IRRITATION TO RESPIRATORY TRACT.

Explanation of Carcinogenicity: N/R

Signs and Symptoms of Overexposure: EYES- IRRITATION. SKIN- IRRITATION. INGESTION- GASTROINTESTINAL DISCOMFORT. INHALATION- RESPIRATORY TRACT IRRITATION.

Medical Conditions Aggravated by Overexposure: NONE SPECIFIED BY MANUFACTURER.

==============================================================================
FIRST AID
==============================================================================
EYES- FLUSH WITH WATER FOR AT LEAST 15 MIN. RAISING AND LOWERING EYELIDS OCCASIONALLY. SKIN- THOROUGHLY WASH EXPOSED AREA FOR AT LEAST 15 MIN. REMOVE CONTAMINATED CLOTHING. LAUNDER CLOTHING BEFORE REUSE. INGESTION- IF CONSCIOUS, GIVE PLEN TY OF WATER. INHALATION- REMOVE TO FRESH AIR. GIVE OXYGEN IF BREATHING HAS STOPPED. KEEP PERSON WARM, QUIET, AND GET MEDICAL ATTENTION.

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: NO INFORMATION

Auto Ignition Temperature Text: 

Lower Limits: N/R Upper Limits: N/R

Extinguishing Media: USE MEDIA SUITABLE TO EXTINGUISH SURROUNDING FIRE.

Fire Fighting Procedures: FIREFIGHTERS SHOULD WEAR FULL PROTECTIVE EQUIPMENT AND NIOSH APPROVED SELF-CONTAINED BREATHING APPARATUS.

Unusal Fire/Explosion Hazard: EXCESSIVE TEMPERATURES MAY EMIT TOXIC AND CORROSIVE FUMES OF IODINE.

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: VENTILATE AREA OF SPILL. ELIMINATE ALL SOURCES OF IGNITION. REMOVE ALL NON-ESSENTIAL PERSONNEL FROM AREA. CLEAN-UP PERSONNEL SHOULD WEAR PROPER PROTECTIVE EQUIPMENT AND CLOTHING. ABSORB MATERIAL WITH SUITABLE ABSORBANT AND CONTAINERIZE FOR DISPOSAL.
Neutralizing Agent: N/R

Waste Disposal Methods: DISPOSE IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS. ALWAYS CONTACT A PERMITTED WASTE DISPOSER (TSD) TO ASSURE COMPLIANCE.

==============================================================================
HANDLING AND STORAGE
==============================================================================
STORE TIGHTLY CLOSED IN A COOL, DRY, WELL VENTILATED AREA AWAY FROM INCOMPATIBLE MATERIALS.

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: A NIOSH/MSHA CHEMICAL CARTRIDGE RESPIRATOR SHOULD BE WORN IF PEL OR TLV IS EXCEEDED.
Ventilation: LOCAL EXHAUST OR MECHANICAL (GENERAL) VENTILATION.
Protective Gloves: RUBBER, NIOPRENE, PVC, OR EQUIVALENT.
Eye Protection: SPLASH PROOF CHEMICAL SAFETY GOGGLES.
Other Equipment: LAB COAT, EYE WASH, AND SAFETY SHOWER.
Work Hygenic Practices: LAB COAT, EYE WASH, AND SAFETY SHOWER.
Supplemental Safety & Health: PRODUCT IS AN AQUEOUS SOLUTION.

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
HCC: N1
Boiling Point: 
212F,100C
Melting/Freezing Point: 
NO INFO
Decomposition Temp: 
N/K
Vapor Pressure: 17.535 Vapor Density: NO INFO
Specific Gravity: 1.0
PH: N/R
Viscosity: N/P
Evaporation Rate & Reference: 1 (WATER=1)
Solubility in Water: COMPLETE
Appearance and Odor: DEEP AMBER LIQUID WITH SLIGHT CHARACTERISTIC ODOR OF IODINE.
Percent Volatiles by Volume: 99
Corrosion Rate: N/K

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: HIGH TEMPERATURES OR EXCESSIVE HEAT.
Materials to Avoid: CONTACT WITH AMMONIA FUMES MAY CAUSE FORMATION OF EXPLOSIVE NITROIDIDE.
Hazardous Decomposition Products: FREE IODINE
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: N/R

==============================================================================
TOXICOLOGICAL
==============================================================================
N/P

==============================================================================
ECOLOGICAL
==============================================================================
N/P

==============================================================================
DISPOSAL
==============================================================================
DISPOSE IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS. ALWAYS CONTACT A PERMITTED WASTE DISPOSER (TSD) TO ASSURE COMPLIANCE.

==============================================================================
TRANSPORTATION
==============================================================================
N/P

==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media