> Blulux Laboratories Pvt. Ltd.

CAS # 79-14-1 GLYCOLIC ACID (70%) IN WATER

Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad - 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300 
Fax : + 91 129 4190333
E-mail: bluluxlab@gmail.com  Website : www.blulux.com


 

HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: NO Ingestion: YES
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO

Health Hazards Acute And Chronic: SKIN/EYE: BURNS. INGEST: MAY BE FATAL.

Explanation of Carcinogenicity: NOT RELEVANT

Signs and Symptoms of Overexposure: SEE HEALTH HAZARDS.

Medical Conditions Aggravated by Overexposure: NONE SPECIFIED BY MANUFACTURER.

==============================================================================
FIRST AID
==============================================================================
INGEST: IF SWALLOWED & PERSON IS CONSCIOUS. IMMEDIATELY GIVE LARGE AMOUNTS OF WATER. GET MEDICAL ATTENTION. INHAL: REMOVE TO FRESH AIR. IF NOT BREATHING. GIVE ARTF RESP. IF BREATHING IS DIFFICULT, GIVE OXYGEN. SKIN: FLUSH SKIN W/WATER. EYE: IMMED FLUSH WITH PLENTY OF WATER FOR AT LEAST 15 MIN.

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: NOT APPLICABLE

Auto Ignition Temperature Text: 

Lower Limits: N/K Upper Limits: N/K

Extinguishing Media: USE EXTINGUISHING MEDIA APPROPRIATE FOR SURROUNDING FIRE.

Fire Fighting Procedures: FIRE FIGHTERS SHOULD WEAR NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE EQUIPMENT (FPN ).

Unusal Fire/Explosion Hazard: NONE IDENTIFIED.

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT CLTHG. STOP LEAK IF YOU CAN DO SO WITHOUT RISK. VENT AREA. NEUT SPILL W/ SODA ASH OR LIME. WITH CLEAN SHOVEL. CAREFULLY PLACE MATERIAL INTO CLEAN, DRY CNTNR & COVER; REMOVE FROM AREA. FLUSH SPILL AREA W/WATER.
Neutralizing Agent: SODA ASH/LIME.

Waste Disposal Methods: DISPOSE IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE & LOCAL ENVIRONMENTAL REGULATIONS.

==============================================================================
HANDLING AND STORAGE
==============================================================================
KEEP CONTAINER TIGHTLY CLOSED. STORE IN A COOL, DRY, WELL-VENTILATED AREA. STORE ABOVE 10C.

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: NONE REQUIRED WHERE ADEQUATE VENTILATION CONDITIONS EXIST. IF AIRBORNE CONCENTRATION IS HIGH, USE APPROPRIATE NIOSH/ MSHA APPROVED RESPIRATOR OR DUST MASK.
Ventilation: USE ADEQUATE GENERAL OR LOCAL EXHAUST VENT TO KEEP VAPOR AND MIST LEVELS AS LOW AS POSSIBLE. VENT HOOD.
Protective Gloves: RUBBER GLOVES.
Eye Protection: CHEMICAL SAFETY GOGGLES (FP N).
Other Equipment: EMERGENCY EYEWASH AND DELUGE SHOWER (FP N). LAB COAT.
Work Hygenic Practices: EMERGENCY EYEWASH AND DELUGE SHOWER (FP N). LAB COAT.
Supplemental Safety & Health: NONE SPECIFIED BY MANUFACTURER.

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
HCC: B3
Boiling Point: 
241F,116C
Melting/Freezing Point: 
50F,10C
Decomposition Temp: 
N/K
Vapor Pressure: 11.2 Vapor Density: 0.6
Specific Gravity: 1.27 (H2O=1)
PH: N/A
Viscosity: N/P
Evaporation Rate & Reference: NOT APPLICABLE
Solubility in Water: COMPLETE (100%)
Appearance and Odor: CLEAR, YELLOW-BROWN LIQUID BURNT SUGAR ODOR.
Percent Volatiles by Volume: 30
Corrosion Rate: N/K

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: FREEZING.
Materials to Avoid: STRONG OXIDIZING AGENTS, NITRIC ACID, CYANIDES, NITRATES, NITRITES, MOST COMMMON METALS.
Hazardous Decomposition Products: HYDROGEN.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: NOT RELEVANT

==============================================================================
TOXICOLOGICAL
==============================================================================
N/P

==============================================================================
ECOLOGICAL
==============================================================================
N/P

==============================================================================
DISPOSAL
==============================================================================
DISPOSE IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE & LOCAL ENVIRONMENTAL REGULATIONS.

==============================================================================
TRANSPORTATION
==============================================================================
N/P

==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media