> Blulux Laboratories Pvt. Ltd.

CAS # 97-53-0 EUGENOL EXTRA PURE

Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad - 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300 
Fax : + 91 129 4190333
E-mail: bluluxlab@gmail.com  Website : www.blulux.com


 

HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: NO Skin: YES Ingestion: YES
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO

Health Hazards Acute And Chronic: EYE: MAY CAUSE IRRITATION. SKIN: MAY CAUSE IRRITATION & ALLERGIC REACTION. INGESTION: PRODUCT IS OF LOW ORAL TOXICITY.

Explanation of Carcinogenicity: NONE

Signs and Symptoms of Overexposure: SKIN: PROLONGED/REPEATED CONTACT MAY CAUSE IRRITATION & ALLERGIC REACTION & IRRITATION. EYE: MAY CAUSE IRRITATION. INGESTION: PRODUCT IS OF LOW ORAL TOXICITY.

Medical Conditions Aggravated by Overexposure: ALLERGIC REACTION.

==============================================================================
FIRST AID
==============================================================================
EYE: FLUSH W/PLENTY OF WATER FOR 15 MINS. GET MED ATTN. SKIN: WASH W/PLENTY OF SOAP & WATER. GET MED ATTN. INHALATION: REMOVE TO FRESH AIR, IF BREATHING IS DIFFICULT ADMINISTER OXYGEN. IF BREATHING HAS STOPPED ADMINISTER ARTIFICIAL RESPIRAT ION. INGESTION: GIVE MILK OR WATER TO DILUTE. TREAT SYMPTOMATICALLY.

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: 253F

Auto Ignition Temperature Text: 

Lower Limits: N/K Upper Limits: N/K

Extinguishing Media: WATER SPRAY, DRY CHEMICAL, CO2

Fire Fighting Procedures: WEAR SELF-CONTAINED BREATHING APPARATUS/PROTECTIVE CLOTHING.

Unusal Fire/Explosion Hazard: AVOID HEAT & OPEN FLAME.

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: REMOVE ALL SOURCES OF IGNITION. ABSORB MATERIAL W/VERMICULITE OR OTHER SUITABLE ABSORBENT & PLACE IN A DOT APPROVED CONTAINER.
Neutralizing Agent: N/K

Waste Disposal Methods: DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE, & LOCAL REGULATIONS. COMBUSTIBLE LIQUID.

==============================================================================
HANDLING AND STORAGE
==============================================================================
AVOID CONTACT W/EYES, SKIN & CLOTHING. STORE AWAY FROM STRONG OXIDIZERS.

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: NOT NEED UNDER NORMAL CONDITIONS OF USE.
Ventilation: MECHANICAL VENTILATION IS ADEQUATE UNDER NORMAL CONDITIONS OF USE.
Protective Gloves: IMPERVIOUS, NEOPRENE
Eye Protection: SAFETY GLASSES
Other Equipment: APRON OR OTHER PROTECTIVE CLOTHING.
Work Hygenic Practices: APRON OR OTHER PROTECTIVE CLOTHING.
Supplemental Safety & Health: N/K

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
Boiling Point: 
489F
Melting/Freezing Point: 
-11C
Decomposition Temp: 
N/K
Vapor Pressure: N/K Vapor Density: 5.68
Specific Gravity: 1.0664
PH: N/K
Viscosity: N/P
Evaporation Rate & Reference: N/K
Solubility in Water: NEGLIGIBLE
Appearance and Odor: LIGHT YELLOW LIQUID; ODOR OF CLOVES.
Percent Volatiles by Volume: N/K
Corrosion Rate: N/K

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: HEAT & OPEN FLAME
Materials to Avoid: STRONG OXIDIZERS, NITRIC ACID, HYDROGEN PEROXIDE, PERCHLORIC ACID, & CHROMIC ACID.
Hazardous Decomposition Products: CO, CO2
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: N/R

==============================================================================
TOXICOLOGICAL
==============================================================================
N/P

==============================================================================
ECOLOGICAL
==============================================================================
N/P

==============================================================================
DISPOSAL
==============================================================================
DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE, & LOCAL REGULATIONS. COMBUSTIBLE LIQUID.

==============================================================================
TRANSPORTATION
==============================================================================
N/P

==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media