HAZARD
IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: YES
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO
Health Hazards Acute And Chronic: ALL CHEMICALS SHOULD BE CONSIDERED HAZARDOUS
- AVOID DIRECT PHYSICAL CONTACT! LACHRYMATOR-CAUSES SEVERE EYE IRRITATION.
VAPORS &/OR DIRECT EYE CONTACT CAN CAUSE SEVERE EYE BURNS. CAN CAUSE SEVERE
SKIN BURNS. CAN BE HARMFUL IF SWALLOWED. CAN BE HARMFUL IF INHALED. CAN BE
HARMFUL IF ABSORBED THROUGH (EFTS OF OVEREXP)
Explanation of Carcinogenicity: NOT RELEVANT
Signs and Symptoms of Overexposure: HLTH HAZ:SKIN. EXTREMELY DESTRUCTIVE OF
MUCOUS MEMBRANES &/OR UPPER RESPIRATORY TRACT. CAN BE FATAL IF INHALED!
PROLONGED EXPOSURE MAY CAUSE NAUSEA, HEADACHE, DIZZINESS &/OR EYE DAMAGE.
ASSUME THIS CHEMICAL IS TOXIC & USE SPECIAL CARE TO AV OID CONTACT.
Medical Conditions Aggravated by Overexposure: NONE SPECIFIED BY MANUFACTURER.
==============================================================================
FIRST AID
==============================================================================
INGEST:CALL MD IMMED (FP N). EYES:FLUSH CONTINUOUSLY W/WATER FOR AT LST 15-20
MINS. SKIN:FLUSH W/WATER FOR 15-20 MINS. IF NO BURNS HAVE OCCURRED-USE SOAP
& WATER TO CLEANSE SKIN. REMOVE & WASH CONTAM CLTHG. GET MED ATTN IF
NEC. DO NOT WEAR SHOES/CLTHG UNTIL ABSOLUTELY FREE OF ALL CHEM ODORS.
INHAL:REMOVE PATIENT TO FRESH AIR. ADMIN OXYG IF PATIENT IS HAVING DFCLTY
BRTHG. IF PATIENT HAS (SUPDAT)
==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: 117F,47C
Auto Ignition Temperature Text:
Lower Limits: N/K Upper Limits: N/K
Extinguishing Media: CARBON DIOXIDE OR DRY CHEMICAL POWDER. DO NOT USE WATER.
Fire Fighting Procedures: USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT (FP N).
Unusal Fire/Explosion Hazard: THIS IS COMBUSTIBLE COMPOUND. NO EXPLOSION LIMITS
ARE AVAILABLE FOR THIS COMPOUND.
==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: EVACUATE AREA. WEAR APPROPRIATE OSHA-REGULATED
EQUIPMENT. VENTILATE AREA. ABSORB ON VERMICULITE OR SIMILAR MATERIAL. SWEEP UP
& PLACE IN AN APPROPRIATE CONTAINER. HOLD FOR DISPOSAL. WASH CONTAMINATED
SURFACES TO REMOVE ANY RESIDUES.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS (FP N). BURN IN A CHEMICAL INCINERATOR EQUIPPED W/AFTERBURNER &
SCRUBBER.
==============================================================================
HANDLING AND STORAGE
==============================================================================
AVOID CONTACT W/SKIN, EYES & CLOTHING. KEEP TIGHTLY CLOSED & STORE IN A
COOL, DRY PLACE. STORE ONLY W/COMPATIBLE CHEMICALS.
==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE
OF CONCERN (FP N).
Ventilation: THIS CHEMICAL SHOULD BE HANDLED ONLY IN A HOOD.
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS (ING 3)
Other Equipment: EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET ANSI DESIGN
CRITERIA (FP N). USE APPROPRIATE OSHA/MSHA SAFETY EQUIPMENT.
Work Hygenic Practices: EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET ANSI
DESIGN CRITERIA (FP N). USE APPROPRIATE OSHA/MSHA SAFETY EQUIPMENT.
Supplemental Safety & Health: FIRST AID PROC:STOPPED BRTHG ADMIN ARTF RESP.
IF PATIENT IS IN CARDIAC ARREST ADMIN CPR. CONTINUE LIFE SUPPORTING MEASURES
UNTIL MED ASSISTANCE HAS ARRIVED. NOTE:AN ANTIDOTE IS A SUBSTANCE INTENDED TO
COUNTERACT EFT OF POIS. IT SHOULD BE AD MINISTERED ONLY BY MD/TRAINED EMER
PERS. MED ADVICE CAN BE OBTAINED FROM (ING 2)
==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
Boiling Point:
318F,159C
Melting/Freezing Point:
N/K
Decomposition Temp:
N/K
Vapor Pressure: N/K Vapor Density: N/K
Specific Gravity: 1.506
PH: N/K
Viscosity: N/P
Evaporation Rate & Reference: N/K
Solubility in Water: N/K
Appearance and Odor: COLORLESS TO YELLOW LIQUID; PUNGENT, ACRID ODOR.
Percent Volatiles by Volume: N/K
Corrosion Rate: N/K
==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: CORROSIVE. COMBUSTIBLE.
Materials to Avoid: INCOMPATIBLE W/STRONG ACIDS, STRONG BASES, STRONG OXIDIZING
AGENTS, STRONG REDUCING AGENTS.
Hazardous Decomposition Products: DECOMPOSITION LIBERATES TOXIC FUMES.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: NOT RELEVANT
==============================================================================
DISPOSAL
==============================================================================
DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL REGULATIONS (FP N). BURN IN A
CHEMICAL INCINERATOR EQUIPPED W/AFTERBURNER & SCRUBBER.
==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================
Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals,
Analytical Reagents & Dehydrated Culture Media