> Blulux Laboratories Pvt. Ltd.

CAS #  DPX MOUNTANT for Microscopy

Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad - 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300 
Fax : + 91 129 4190333
E-mail: bluluxlab@gmail.com  Website : www.blulux.com


 

HAZARD IDENTIFICATION
==============================================================================
Product Name: DPX Mountant for microscopy
Chemical Name/Other Name: DPX mountants      
Chemical Formula:
CH3C6H4CH3, C6H4(COO.C4H9)2, (C8H8)n
Chemical Family: Organic solution
TDG Shipping Name/UN: Flammable liquid, N.O.S (Xylene) UN 1993
TDG Classification/Packing group: 3  PG III
Use: Laboratory reagent, industrial processes
==============================================================================
                     Section II Hazardous Ingredients
==============================================================================
Chemical name                             CAS No.                         %

Xylene                                        1330-20-7                   73 (v/v)
Di-n-butyl Phtthalate                    84-74-2                     10 (v/v)
Lustrex crystal (Polystyrene)        100-42-5                    21 (w/v)
==============================================================================
                        Section III Physical Data
==============================================================================
Physical State:
Liquid
Appearance and Odour: Colourless liquid; characteristic odour
Odour Threshold: Not available
Specific Gravity: Not available
Vapour Pressure: Not available
Vapour Density: Not available
Evaporation Rate: Not available               
Boiling Point: Not available
Freezing Point: Not available
Solubility in water: Immiscible or insoluble
pH: Not available
Coefficient of water/oil distribution: Not available          
==============================================================================
                   Section IV Fire or Explosion Hazard
==============================================================================
Conditions of Flammability:
Flammable. Readily ignited in almost all ambient conditions. Vapour may travel to distant sources of ignition and flashback may occur.
Extinguishing Media: Carbon dioxide, dry chemical, foam, do not use direct water stream, vaporizing liquids
Flash point / method: 25°C/cc
UEL: 7.0 %                                                            
LEL: 1.1 %
Autoignition Temperature: 465°C
Hazardous Combustion Products: COx
Explosion data - sensitivity to mechanical impact: No
               - sensitivity to static discharge: May be ignited by static discharge
==============================================================================
                        Section V Reactivity Data
==============================================================================
Conditions of instability:
Normally stable 
Incompatibilities: Strong oxidizers, light metals, rubber, various plastics
Conditions of reactivity: Normally stable
Hazardous decomposition products: COx and various hydrocarbons
==============================================================================
          Section VI Toxicological Properties / Health Hazard Data
==============================================================================
Route of entry:
  
   -skin contact: Irritates
   -skin absorption: Risk of absorption is slight
   -eye contact: Severe irritation
   -inhalation: Irritates
   -ingestion: Harmful
LC50: Not available
LD50: 4300 mg/kg (orl-rat) (Xylene)
Exposure Limits: Not available
Affects of Acute Exposure: Exposure to this product causes irritation to the eye, lungs and mucous membranes. Chest pain may also occur.
Affects of Chronic Exposure: Exposure to this product may cause dermatitis, damage to the liver and kidneys and may cause blood effects.
Irritancy: Standard Draize Test: skn,rbt 500mg/24H-mod; eye,rbt 5mg/24H-sev (xylene)
Sensitization to Product: No information available
Carcinogenicity: No information available
Reproductive Toxicity: May cause reproductive effects, references cited: RTECS# ZE2100000 (xylene)
Teratogenicity: May cause teratogenic effects, references cited:RTECS#ZE2100000 (Xylene)
Mutagenicity: No information available
Toxicologically Synergistic Products: None found
==============================================================================
                      Section VII First aid measures
==============================================================================
Skin:
Flush the contact area with lukewarm running water for at least 15 minutes. Remove contaminated clothing, taking care not to spread the chemical. If contamination is extensive, remove clothing under running water. Discard or decontaminate clothing under running water. Discard or decontaminate clothing before use. Unless contact has been slight, seek medical attention. Seek medical attention if irritation persists.
Eye: Flush the contaminated eye(s) for at least 15 minutes with lukewarm running water, holding the eyelids open. Take care not to rinse contaminated water into the non-affected eye. Always seek medical attention for accidents involving the eyes.
Inhalation: Take proper precautions to ensure your own safety before attempting rescue. Remove source of contamination or move victim to fresh air. If breathing has stopped, trained personnel should begin artificial respiration, or if the heart has stopped, cardiopulmonary resuscitation (CPR) immediately. Seek medical attention.
Ingestion: Never give anything by mouth if victim is rapidly losing consciousness, or is unconscious or convulsing. Rinse mouth thoroughly with water. Do not induce vomiting. Have victim drink 200-400 ml of water to dilute. If breathing has stopped, trained personnel should begin artificial respiration, or if the heart has stopped, cardiopulmonary resuscitation (CPR)
immediately. Seek medical attention.
==============================================================================
                     Section VIII Preventive Measures
==============================================================================
Engineering Controls:
Engineering control methods to reduce hazardous exposures are preferred. Methods include mechanical ventilation (dilution and local exhaust), process or personnel enclosure, control of process conditions, and
process modification. Administrative controls and personal protective equipment may also be required. Use a non-sparking grounded ventilation system separate from other exhaust ventilation systems. Exhaust directly to the outside.
Provide sufficient local exhaust and general ventilation to maintain levels below 10 % of the lower explosive limit.
Personal protective equipment: 
   -gloves: Nitrile, rubber
   -respiratory protection: Approved respirator, fumehood as appropriate
   -eye protection: Chemical safety goggles or face shield
   -clothing: Plastic apron, sleeves and boots as appropriate
Storage Requirements: Store at room temperature(15¼C to 25¼C recommended). Keep containers tightly closed and protected from direct sunlight and moisture. Protect from damage. Store away from ignition sources. Store away from
incompatible materials. Use approved flammable liquid storage containers in the work area. Ground drums and bond transfer containers. Use non-sparking tools. Keep material away from sparks, flames and other ignition sources. Post "No Smoking" signs in area of use.
Handling Procedures and Equipment:  Follow routine safe handling procedures. Keep away from materials which can burn. Avoid generating mist.
Leak or Spill Clean-up: Before dealing with spillages take necessary protective measures, inform others to keep at a safe distance and, for flammable materials, shut off all possible sources of ignition. Absorb on inert absorbent, transfer to container and arrange removal by disposals company. Wash site of spillage thoroughly with water and detergent. Ventilate area to dispel residual vapour.
Disposal: Follow all federal, provincial  and local regulations for disposal. Use only licensed disposal and waste hauling companies. Disposal of small amounts of spilled material may be handled as described under "Leak or Spill Cleanup". Large spills must be dealt with separately and must be handled by qualified disposal companies.  
Special Shipping Information: Follow all TDG regulations and see classification in Section I
==============================================================================
                    Section IX Preparation Information
==============================================================================
Prepared by: BLULUX LABORATORIES (P) LTD.

For questions contact:
Blulux Laboratories Pvt. Ltd.

79/66-B, I.H.I.Complex, Industrial Area, N.I.T. Faridabad, Haryana-121001

TEL: :++91-129-5021360, 2444433, 2237762  FAX:++ 91129-5027762 E-MAIL: blulux@rediffmail.com

The statements contained herein are offered for informational purposes only and are based upon technical data that Blulux Laboratories Pvt. Ltd.  believes to be accurate. It is intended for use only by persons having the necessary technical skills and at
their own discretion and risk. Since conditions and manner of use are outside our control, we make NO WARRANTY,EXPRESS OR IMPLIED,OF MERCHANTABILITY,FITNESS OR OTHERWISE.

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media