> Blulux Laboratories Pvt. Ltd.

CAS # 109-89-7 DIETHYLAMINE

Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad - 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300 
Fax : + 91 129 4190333
E-mail: bluluxlab@gmail.com  Website : www.blulux.com


 

HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: YES
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO

Health Hazards Acute And Chronic: ACUTE:INHAL:SEVERE IRRITATION OF RESPIRATORY SYSTEM, MAY CAUSE PULMONARY EDEMA. EYE CONTACT:SEVERE IRRITATION OR BURNS. SKIN ABSORPTION:RAPID ABSORPTION. SKIN CONTACT:SEVERE IRRITATION OR BURNS, PROLONGED CONTACT MAY CAUSE SENSITIZATION. IN GEST:NAUSEA, VOMITING, GASTROINTESTINAL IRRITATION, (EFTS OF OVEREXP)

Explanation of Carcinogenicity: NOT RELEVANT

Signs and Symptoms of Overexposure: HLTH HAZ:BURNS TO MOUTH & THROAT. CHRONIC:NONE IDENTIFIED. TARGET ORGANS:RESPIRATORY SYSTEM, SKIN, EYES.

Medical Conditions Aggravated by Overexposure: NONE IDENTIFIED.

==============================================================================
FIRST AID
==============================================================================
INGEST:CALL MD. IF SWALLOWED, DO NOT INDUCE VOMITING. IF CONSCIOUS, GIVE WATER, MILK OR MILK OF MAGNESIA. INHAL:REMOVE TO FRESH AIR. IF NOT BREATHING, GIVE ARTIFICIAL RESPIRATION. IF BREATHING IS DIFFICULT, GIVE OXYGEN. SKIN:FLUSH W/WATER. EYE:IMMEDIATELY FLUSH W/PLENTY OF WATER FOR AT LEAST 15 MINUTES.

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: -20F,-29C

Auto Ignition Temperature Text: 

Lower Limits: 1.8% Upper Limits: 10.1%

Extinguishing Media: USE ALCOHOL FOAM, DRY CHEMICAL OR CARBON DIOXIDE. (WATER MAY BE INEFFECTIVE).

Fire Fighting Procedures: USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP (FP N). MOVE CNTNRS FROM FIRE AREA IF IT CAN BE DONE W/OUT RISK. USE WATER TO KEEP FIRE-EXPOSED CNTNRS COOL.

Unusal Fire/Explosion Hazard: VAPS MAY FLOW ALONG SURFS TO DIST IGNIT SOURCES & FLASH BACK. CLSD CNTNRS EXPOS TO HEAT MAY EXPLODE. CONT W/STRONG OXIDIZERS MAY CAUSE FIRE.

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT CLTHG. SHUT OFF IGNIT SOURCES; NO FLARES, SMOKING/FLAMES IN AREA. STOP LEAK IF YOU CAN DO SO W/OUT RISK. USE WATER SPRAY TO REDUCE VAPS. TAKE UP W/SAND OR OTHER NON-COMBUST ABSORB MATL & PLACE INTO (S UPP DATA)
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.

Waste Disposal Methods: DISPOSE I/A/W ALL APPLICABLE FEDERAL, STATE & LOCAL ENVIRONMENTAL REGULATIONS. EPA HAZARDOUS WASTE NUMBERS:D001, D002 (IGNITABLE, CORROSIVE WASTE).

==============================================================================
HANDLING AND STORAGE
==============================================================================
KEEP CNTNR TIGHTLY CLSD. STORE IN COOL, DRY, WELL-VENTILATED FLAMM LIQ STORAGE AREA. BOND & GROUND CNTNRS WHEN TRANSFERRING LIQUID. HIGHLY FLAMM.

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: NIOSH/MSHA APPROVED RESP PROT REQUIRED IF AIRBORNE CONC EXCEEDS TLV. AT CONCS UP TO 1500 PPM, A NIOSH/MSHA APPRVD CHEM CARTRIDGE RESP W/AMMONIA OR AMINE CARTRIDGE IS REC. ABOVE THIS LEVEL, A NIOSH/MSHA APPRVD SCBA IS ADVISED.
Ventilation: USE GENERAL OR LOCAL EXHAUST VENTILATION TO MEET TLV REQUIREMENTS. VENT HOOD.
Protective Gloves: NEOPRENE GLOVES.
Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS(SUPDAT)
Other Equipment: EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET ANSI DESIGN CRITERIA (FP N). UNIFORM, APRON, LAB COAT ARE REC.
Work Hygenic Practices: EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET ANSI DESIGN CRITERIA (FP N). UNIFORM, APRON, LAB COAT ARE REC.
Supplemental Safety & Health: SPILL PROC:CONTAINER FOR LATER DISPOSAL. FLUSH AREA W/WATER. OTHER PREC:NO SMOKING. DO NOT EMPTY INTO DRAINS. EYE PROT:& FULL LENGTH FACESHIELD (FP N).

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
Boiling Point: 
132F,56C
Melting/Freezing Point: 
-58F,-50C
Decomposition Temp: 
N/K
Vapor Pressure: 194 @ 20C Vapor Density: 2.5
Specific Gravity: 0.71 (H*2O=1)
PH: N/A
Viscosity: N/P
Evaporation Rate & Reference: 16.9 (BUTYL ACETATE=1)
Solubility in Water: COMPLETE
Appearance and Odor: COLORLESS LIQUID; AMMONIA ODOR.
Percent Volatiles by Volume: 100
Corrosion Rate: N/K

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: HEAT, FLAME, OTHER SOURCES OF IGNITION.
Materials to Avoid: STRONG ACIDS, STRONG OXIDIZING AGENTS, MOST COMMON METALS.
Hazardous Decomposition Products: OXIDES OF NITROGEN, CARBON MONOXIDE, CARBON DIOXIDE.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: NOT RELEVANT

==============================================================================
TOXICOLOGICAL
==============================================================================
N/P

==============================================================================
ECOLOGICAL
==============================================================================
N/P

==============================================================================
DISPOSAL
==============================================================================
DISPOSE I/A/W ALL APPLICABLE FEDERAL, STATE & LOCAL ENVIRONMENTAL REGULATIONS. EPA HAZARDOUS WASTE NUMBERS:D001, D002 (IGNITABLE, CORROSIVE WASTE).

==============================================================================
TRANSPORTATION
==============================================================================
N/P

==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media