> Blulux Laboratories Pvt. Ltd.

CAS # 111-92-2 DI-N-BUTYLAMINE

Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad - 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300 
Fax : + 91 129 4190333
E-mail: bluluxlab@gmail.com  Website : www.blulux.com


 

HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: YES Ingestion: YES
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO

Health Hazards Acute And Chronic: ACUTE: INHAL:LOW CONCS MAY CAUSE SORE THROAT, COUGH, CHOKING, DYPSNEA & VARIABLE SYMPS OF HDCH, DIZZ & WEAK. INTENSE EXPOS MAY RSLT IN CHEST TIGHTNESS & DELAYED PULM EDEMA. SOLUBILITY OF SUBSTANCE ALLOWS FURTHER PENETRATION THAT MAY CONTINU E FOR SEVERAL DAYS. SKIN:SUBSTANCE PENETRATES SKIN SLOWLY, (EFTS OF OVEREXP)

Explanation of Carcinogenicity: NOT RELEVANT

Signs and Symptoms of Overexposure: HLTH HAZ:PRODUCING SOFT, NECROTIC, DEEPLY PENETRATING AREAS ON CNTCT. SOLUBILITY ALLOWS FURTHER PENETRATION THAT MAY CONTINUE FOR SEVERAL DAYS. EXTENT OF DMG DEPENDS ON DURATION OF CNTCT. BECAUSE OF LOW SOLUBILITY & APPARENTLY SLOW PENETRAT ION INTO TISS, ITS AQ SOLNS ARE NOT CORR. EYE:DIRECT CNTCT W/SOLID OR AQ (ING 4)

Medical Conditions Aggravated by Overexposure: NONE SPECIFIED BY MANUFACTURER.

==============================================================================
FIRST AID
==============================================================================
INHAL:REMOVE TO FRESH AIR IMMED. PERFORM ARTF RESP IF NEC. MAINTAIN AIRWAY, BLOOD PRESS & RESP. KEEP WARM & AT REST. TREAT SYMP & SUPPORTIVELY. GET MED ATTN IMMED. QUALIFIED MED PERS SHOULD CONSIDER ADMIN O*2. SKIN:REMOVE CONTAMD CLTHG & SH OES IMMED. WASH W/SOAP & LG AMTS OF WATER UNTIL NO EVID OF CHEM REMAINS (AT LST 15-20 MIN). IF BURNS OCCUR:COVER AREA SECURELY W/STERILE, DRY, LOOSE- (ING 12)

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: 117F,47C

Auto Ignition Temperature Text: 

Lower Limits: 1.1% Upper Limits: N/K

Extinguishing Media: DRY CHEM, CARBON DIOXIDE, WATER SPRAY/REGULAR FOAM. FOR LARGER FIRES, USE WATER SPRAY, FOG/REGULAR FOAM. ALCOHOL FOAM.

Fire Fighting Procedures: NIOSH APPRVD SCBA & FULL PROT EQUIP (FP N). MOVE CNTNR FROM AREA IF W/OUT RISK. APPLY COOLING WATER TO CNTNR SIDES EXPOS TO FLAMES UNTIL WELL AFTER FIRE(SUPDAT)

Unusal Fire/Explosion Hazard: MOD FIRE HAZ WHEN EXPOS TO HEAT/FLAME. VAPS ARE HVR/AIR & MAY TRAVEL CONSIDERABLE DISTANCE TO IGNIT SOURCE & FLASH BACK. VAPOR-AIR MIXS ARE EXPLO ABOVE FL PT.

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: SHUT OFF IGNIT SOURCES. DO NOT TOUCH SPILL. STOP LEAK IF W/OUT RISK. USE WATER SPRAY TO REDUCE VAPS. SM SPILL:TAKE UP W/ABSORB & PLACE INTO CNTNRS FOR DISP. LG SPILL:DIKE FOR DISP. NO SMKNG/FLARES/FLAMES. KEEP UNNEC PERS AWAY. ISOLATE & DEN Y ENTRY.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.

Waste Disposal Methods: DISPOSAL MUST BE IN ACCORDANCE WITH STANDARDS APPLICABLE TO GENERATORS OF HAZARDOUS WASTE, 40 CFR 262. EPA HAZARDOUS WASTE NUMBERS D001 AND D002. 100 POUND CERCLA SECTION 103 REPORTABLE QUANTITY.

==============================================================================
HANDLING AND STORAGE
==============================================================================
OBSERVE ALL FED, STATE & LOC REGS WHEN STORING. STORE I/A/W 29 CFR 1910.106. SUBSTANCES W/LOW ELECTROCONDUCTIVITY, WHICH MAY BE IGNITED BY (ING 18)

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: RESP SELECTED MUST BE BASED ON CONTAM LEVELS FOUND IN WORKPLACE, SPECIFIC OPERATION, MUST NOT EXCEED WORKING LIMS OF RESP & BE NIOSH APPRVD. ANY CHEM CARTRIDGE RESP W/ORG VAP CARTRIDGE(S) & FULL FACEPIECE. ANY GAS MASK W/ORG VAP (ING 21)
Ventilation: PROVIDE LOC EXHST/GEN DILUTION VENT. EQUIP SHOULD BE EXPLO-PROOF IF EXPLO CONCS OF DUST/VAP/FUME ARE PRESENT.
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGS (ING 24)
Other Equipment: ANSI APPROVED EYE WASH & DELUGE SHOWER (FP N). WEAR APPROP PROT (IMPERVIOUS) CLTH & EQUIP TO PVNT SKIN CNTCT.
Work Hygenic Practices: ANSI APPROVED EYE WASH & DELUGE SHOWER (FP N). WEAR APPROP PROT (IMPERVIOUS) CLTH & EQUIP TO PVNT SKIN CNTCT.
Supplemental Safety & Health: PH: BASIC IN SOLN. FIRE FIGHT PROC: IS OUT. STAY AWAY FROM TANK ENDS. W/DRAW IMMED IF RISING SOUND FROM VENTING SFTY DEVICE/ANY DISCOLOR OF TANKD DUE TO FIRE. ISOLATE 1/2 MILE IN ALL DIRECTIONS IF TANK, RAIL CAR/TANK TRUCK INVOLVED. EXTING ONLY IF FLOW CAN BE STOPPED; USE WATER IN FLOODING AMTS AS FOG, SOLID (ING 2)

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
Boiling Point: 
318F,159C
Melting/Freezing Point: 
-76F,-60C
Decomposition Temp: 
N/K
Vapor Pressure: 23 @ 20C Vapor Density: 4.5
Specific Gravity: 0.8
PH: SUPDAT
Viscosity: N/P
Evaporation Rate & Reference: N/K
Solubility in Water: SLIGHT
Appearance and Odor: COLORLESS LIQUID WITH AN AMINE-LIKE ODOR.
Percent Volatiles by Volume: N/K
Corrosion Rate: N/K

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: STABLE UNDER NORMAL TEMPERATURES AND PRESSURES.
Materials to Avoid: ACIDS, ALUMINUM, CELLULOSE NITRATE, CHLORINE, HALOGENATED CMPDS, HYPOCHLORITE, METALS, ORG CMPDS, OXIDIZERS, ZINC.
Hazardous Decomposition Products: THERMAL DECOMPOSITION PRODUCTS MAY INCLUDE HAZARDOUS HYDROCARBONS & AMINE VAPORS & TOXIC OXIDES OF CARBON & NITROGEN.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: NOT RELEVANT

==============================================================================
TOXICOLOGICAL
==============================================================================
N/P

==============================================================================
ECOLOGICAL
==============================================================================
N/P

==============================================================================
DISPOSAL
==============================================================================
DISPOSAL MUST BE IN ACCORDANCE WITH STANDARDS APPLICABLE TO GENERATORS OF HAZARDOUS WASTE, 40 CFR 262. EPA HAZARDOUS WASTE NUMBERS D001 AND D002. 100 POUND CERCLA SECTION 103 REPORTABLE QUANTITY.

==============================================================================
TRANSPORTATION
==============================================================================
N/P

==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media