> Blulux Laboratories Pvt. Ltd.

CAS # D(-)MANNITOL AR

Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad - 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300 
Fax : + 91 129 4190333
E-mail: bluluxlab@gmail.com  Website : www.blulux.com


 

HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: NO Ingestion: YES
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO

Health Hazards Acute And Chronic: TOXICITY CONSIDERED VERY LOW. HANDLING CARE GENERALLY IN KEEPING WITH SAFE LABORATORY PRACTICES IS RECOMMENDED.

Explanation of Carcinogenicity: NOT RELEVANT

Signs and Symptoms of Overexposure: SEE HEALTH HAZARDS.

Medical Conditions Aggravated by Overexposure: DATA NOT AVAILABLE.

==============================================================================
FIRST AID
==============================================================================
GET MEDICAL ASSISTANCE IF ANY ADVERSE EFFECTS SHOULD DEVELOP. SKIN:WASH THOROUGHLY WITH SOAP AND WATER. EYES:IMMEDIATELY FLUSH THOROUGHLY WITH WATER FOR AT LEAST 15 MINUTES. INHALATION:REMOVE TO FRESH AIR; GIVE ARTIFICIAL RESPIRATION IF BRE ATHING HAS STOPPED. INGESTION:GET IMMEDIATE MEDICAL ATTENTION; IF CONSCIOUS, GIVE WATER FREELY.

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: NONE

Auto Ignition Temperature Text: 

Lower Limits: N/A Upper Limits: N/A

Extinguishing Media: USE ANY SUITABLE FOR ADJACENT MATERIAL.

Fire Fighting Procedures: WEAR NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE EQUIPMENT (FP N).

Unusal Fire/Explosion Hazard: NO FLASH POINT IS LISTED, BUT MATERIAL IS CALLED COMBUSTIBLE BY CONDENSED CHEMICAL DICTIONARY (EDITION 11).

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: EVACUATE AREA OF ALL UNNEC PERS. WEAR SUITABLE PROT EQUIP LISTED UNDER CTL MEASURES. ELIM ANY IGNIT SOURCES UNTIL AREA IS DETERM TO BE FREE FROM EXPLO/FIRE HAZS. CNTN RELS & ELIM ITS SOURCE, IF THIS CAN BE DONE W/OUT RISK. TAKE UP & CNTNRIZ E (SUPDAT)
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.

Waste Disposal Methods: MATL DOES NOT HAVE AN EPA WASTE NUMBER & IS NOT LISTED WASTE, HOWEVER CONSULTATION W/PERMITTED WASTE DISP SITE (TSD) SHOULD BE ACCOMPLISHED. ALWAYS CONT PERMITTED WASTE DISP (TSD) TO ASSURE COMPLIANCE W/ALL CURRENT LOC, STATE & FED REGS.

==============================================================================
HANDLING AND STORAGE
==============================================================================
KEEP CONTAINER CLOSED. DO NOT BREATHE DUST. DO NOT GET IN EYES. AVOID PROLONGED OR REPEATED SKIN CONTACT.

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN (FP N).
Ventilation: MATERIAL SHOULD BE HANDLED OR TRANSFERRED IN AN APPROVED FUME HOOD OR WITH ADEQUATE VENTILATION.
Protective Gloves: NEOPRENE OR EQUIV TO PVNT SKIN CONT.
Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS (FP N).
Other Equipment: NONE SPECIFIED BY MANUFACTURER.
Work Hygenic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety & Health: SPILL PROC:FOR PROPER DISPOSAL. COMPLY WITH FEDERAL, STATE AND LOCAL REGULATIONS ON REPORTING RELEASES.

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
Boiling Point: 
>554F,>290C
Melting/Freezing Point: 
>329F,>165C
Decomposition Temp: 
N/K
Vapor Pressure: N/A Vapor Density: N/A
Specific Gravity: 1.52 (H*2O=1)
PH: N/K
Viscosity: N/P
Evaporation Rate & Reference: NOT APPLICABLE
Solubility in Water: SOLUBLE
Appearance and Odor: WHITE POWDER OR GRANULES.
Percent Volatiles by Volume: N/A
Corrosion Rate: N/K

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: NONE INDICATED.
Materials to Avoid: OXIDIZERS.
Hazardous Decomposition Products: CO*X.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: NOT RELEVANT

==============================================================================
TOXICOLOGICAL
==============================================================================
N/P

==============================================================================
ECOLOGICAL
==============================================================================
N/P

==============================================================================
DISPOSAL
==============================================================================
MATL DOES NOT HAVE AN EPA WASTE NUMBER & IS NOT LISTED WASTE, HOWEVER CONSULTATION W/PERMITTED WASTE DISP SITE (TSD) SHOULD BE ACCOMPLISHED. ALWAYS CONT PERMITTED WASTE DISP (TSD) TO ASSURE COMPLIANCE W/ALL CURRENT LOC, STATE & FED REGS.

==============================================================================
TRANSPORTATION
==============================================================================
N/P

==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media