> Blulux Laboratories Pvt. Ltd.

CAS # CUPRIC NITRATE EXTRA PURE TRIHYDRATED

Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad - 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300 
Fax : + 91 129 4190333
E-mail: bluluxlab@gmail.com  Website : www.blulux.com


 

HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: N/P Skin: N/P Ingestion: N/P
Carcinogenicity Inds - NTP: N/P IARC: N/P OSHA: N/P

Health Hazards Acute And Chronic: ACUTE: IRRITATION AND PAIN TO SKIN, EYES, LUNGS, MUCOUS MEMBRANES AND GI TRACT. CHRONIC: SYSTEMIC METAL POISONING HAZARD, DERMATITIS, NASAL DAMAGE.

Explanation of Carcinogenicity: N/P

Signs and Symptoms of Overexposure: NAUSEA, CHILLS, COUGHING.

Medical Conditions Aggravated by Overexposure: PERSONS WITH PREEXISTING SKIN, EYE, KIDNEY/LIVER, HEMATOPOIETIC OR HEART DISORDERS OR WILSON'S DISEASE MAY BE MORE SUSCEPTIBLE.

==============================================================================
FIRST AID
==============================================================================
SKIN: REMOVE ANY CONTAMINATED CLOTHING. WASH SKIN WITH SOAP OR MILD DETERGENT & WATER FOR AT LEAST 15MINS. GET MEDICAL ATTENTION IF IRRITATION DEVELOPS OR PERSISTS. EYE: WASH EYES WITH PLENTY OF WATER FOR AT LEAST 15MINS LIFTING LOWER & U PPER EYELIDS OCCASIONALLY. GET MEDICAL ATTENTION IMMEDIATELY. INHALATION: REMOVE TO FRESH AIR. IF NOT BREATHING, GIVE ARTIFICIAL RESPIRATION. IF BREATHING IS DIFFICULT, GIVE OXYGEN. CALL A PHYSICIAN. INGEST: IF SWALLOWED, INDUCE VOMITI NG IMMEDIATELY BY GIVING 2 GLASSES OF WATER & STICKING FINGER DOWN THROAT. NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. CALL PHYSICIAN IMMEDIATELY.

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: N/P

Auto Ignition Temperature Text: 

Extinguishing Media: USE ANY MEDIUM SUITABLE FOR EXTINGUISHING SUPPORTING FIRE.

Fire Fighting Procedures: USE WATER TO COOL. IN EVENT OF FIRE WEAR FULL PROTIVE CLOTHING & NIOSH APPROVED SELF-CONTAINED BREATHING APPARATUS WITH FULL FACEPCE OPERATED IN PRESSURE DEMAND/OTHER POSITIVE PRESSURE MODE.

Unusal Fire/Explosion Hazard: NOT COMBUSTIBLE BUT IS HAZARDOUS OXIDIZING MATERIAL. IN CONTACT WITH EASILY OXIDIZABLE SUBSTANCES MAY CAUSE IGNITION, VIOLENT COMBUSTION OR EXPLOSION. INCREASES THE FLAMMABILITY OF COMBUSTIBLE MATERIALS.

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: VENTILATE ARE OF LEAK OR SPILL. CLEAN-UP PERSONNEL MAY REQUIRE PROTECTIVE CLOTHING AND RESPIRATORY PROTECTION FROM DUST. SPILLS: SWEEP UP AND CONTAINERIZE FOR RECLAMATION OR DISPOSAL. AVOID DUST DISPERSAL.
Neutralizing Agent: N/P

Waste Disposal Methods: DISPOAL: WHATEVER CANNOT BE SAVED FOR RECLAMATION MAY BE DISPOSED IN A RCRA APPROVED HAZARDOUS WASTE FACILITY. DO NOT FLUSH TO THE SEWER. TOXIC TO AQUATIC LIFE. DISCHARGE, TREATMENT, OR DISPOSAL MAY BE SUBJECT TO FEDERAL, STATE OR LOCAL LAW S.

==============================================================================
HANDLING AND STORAGE
==============================================================================
STORE IN A COOL DRY LOCATION. KEEP CONTAINER TIGHTLY CLOSED WHEN NOT IN USE.

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: DUST
Ventilation: LOCAL EXHAUST VENTILATION: RECOMMENDED. MECHANICAL (GENERAL) VENTILATIONS: RECOMMENDED.
Protective Gloves: VINYL OR RUBBER
Eye Protection: GOGGLES.
Other Equipment: LAB COAT.
Work Hygenic Practices: LAB COAT.
Supplemental Safety & Health: N/P

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
HCC: D1
Boiling Point: =170.C, 338.F
DECOMPOSES
Melting/Freezing Point: =115.C, 239.F

Decomposition Temp: 
N/P
Vapor Pressure: N/P Vapor Density: N/P
Specific Gravity: 2.06
PH: N/P
Viscosity: N/P
Evaporation Rate & Reference: N/P
Solubility in Water: GOOD
Appearance and Odor: BLUE CRYSTALS, NO ODOR.
Percent Volatiles by Volume: N/P
Corrosion Rate: N/P

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: HEAT.
Materials to Avoid: POTASSIUM FERROCYANIDE, TIN, ALUMINUM, STANNOUS CHLORIDE, OXIDIZABLE MATERIALS.
Hazardous Decomposition Products: NITROGEN OXIDES.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: NONE

==============================================================================
TOXICOLOGICAL
==============================================================================
N/P

==============================================================================
ECOLOGICAL
==============================================================================
N/P

==============================================================================
DISPOSAL
==============================================================================
DISPOAL: WHATEVER CANNOT BE SAVED FOR RECLAMATION MAY BE DISPOSED IN A RCRA APPROVED HAZARDOUS WASTE FACILITY. DO NOT FLUSH TO THE SEWER. TOXIC TO AQUATIC LIFE. DISCHARGE, TREATMENT, OR DISPOSAL MAY BE SUBJECT TO FEDERAL, STATE OR LOCAL LAW S.

==============================================================================
TRANSPORTATION
==============================================================================
N/P

==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: Y
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media