HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: NO Ingestion: YES
Carcinogenicity Inds - NTP: YES IARC: YES OSHA: NO

Health Hazards Acute And Chronic: CONTACT W/SKIN OR EYES MAY CAUSE SEVERE IRRITATION OR BURNS. DUST MAY ULCERATE MUCOUS MEMBRANES. EXCESSIVE INHALATION OF DUST IS IRRITATING & MAY BE SEVERELY DAMAGING TO RESPIRATORY PASSAGES &/OR LUNGS. INGESTION MAY RESULT IN SEVERE INTEST INAL IRRITATION W/BURNS TO MOUTH.

Explanation of Carcinogenicity: CHROMIUM TRIOXIDE:GROUP 1(NTP), GROUP 1(IARC).

Signs and Symptoms of Overexposure: SEE HEALTH HAZARDS.

Medical Conditions Aggravated by Overexposure: NONE IDENTIFIED.

==============================================================================
FIRST AID
==============================================================================
CALL MD. INGEST:IF CONSCIOUS, IMMEDIATELY INDUCE VOMITING. INHAL:REMOVE TO FRESH AIR. IF NOT BREATHING, GIVE ARTF RESP. IF BREATHING IS DIFFICULT, GIVE OXYGEN. EYES:IMMEDIATELY FLUSH W/PLENTY OF WATER FOR AT LEAST 15 MINUTES. SKIN:IMMEDIATE LY FLUSH W/PLENTY OF WATER FOR AT LEAST 15 MINUTES WHILE REMOVING CONTAMINATED CLOTHING & SHOES. WASH CLOTHING BEFORE RE-USE.

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: NOT APPLICABLE

Auto Ignition Temperature Text: 

Lower Limits: N/A Upper Limits: N/A

Extinguishing Media: USE WATER SPRAY.

Fire Fighting Procedures: WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP(FP N). MOVE EXPOSED CNTNRS FROM FIRE AREA IF IT CAN BE DONE W/OUT RISK. USE H*2O TO KEEP FIRE-EXPOSED CNTNRS COOL.

Unusal Fire/Explosion Hazard: STRONG OXIDIZER. CONTACT W/OTHER MATL MAY CAUSE FIRE.

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT CLTHG. KEEP COMBUSTIBLES (WOOD, PAPER, OIL, ETC) AWAY FROM SPILLED MATL. WITH CLEAN SHOVEL, CAREFULLY PLACE MATL INTO CLEAN, DRY CNTNR & COVER; REMOVE FROM AREA. FLUSH SPILL AREA W/WATER.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.

Waste Disposal Methods: DISPOSE I/A/W ALL APPLICABLE FEDERAL, STATE & LOCAL ENVIRONMENTAL REGULATIONS. EPA WASTE #D007 (EP TOXIC WASTE).

==============================================================================
HANDLING AND STORAGE
==============================================================================
KEEP CONTAINER TIGHTLY CLOSED. STORE SEPARATELY & AWAY FROM FLAMMABLE & COMBUSTIBLE MATLS. KEEP FROM CONT W/CLTHG & OTHER COMBUST MATLS.

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: NIOSH/MSHA APPRVD RESP PROT REQD IF AIRBORNE CONC EXCEEDS TLV. AT CONCS UP TO 1 PPM, A NIOSH/MSHA APPRVD DUST/MIST RESP IS RECOMMENDED. ABOVE THIS LEVEL, A NIOSH/MSHA APPRVD SCBA IS ADVISED.
Ventilation: USE GENERAL OR LOCAL EXHAUST VENTILATION TO MEET TLV REQUIREMENTS. VENT HOOD.
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: CHEM WORK GOGG/FULL LENGTH FCSHLD(FP N).
Other Equipment: UNIFORM, APRON, LAB COAT. EMERGENCY EYE WASH & DELUGE SHOWER (FP N).
Work Hygenic Practices: UNIFORM, APRON, LAB COAT. EMERGENCY EYE WASH & DELUGE SHOWER (FP N).
Supplemental Safety & Health: NONE SPECIFIED BY MANUFACTURER.

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
HCC: D1
Boiling Point: 
N/A
Melting/Freezing Point: 
387F,197C
Decomposition Temp: 
N/K
Vapor Pressure: N/A Vapor Density: N/A
Specific Gravity: 2.70 (H*2O=1)
PH: N/K
Viscosity: N/P
Evaporation Rate & Reference: NOT APPLICABLE
Solubility in Water: COMPLETE
Appearance and Odor: DARK RED CRYSTALS W/NO ODOR.
Percent Volatiles by Volume: N/A
Corrosion Rate: N/K

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: HEAT.
Materials to Avoid: COMBUSTIBLE MATLS, STRONG REDUCING AGENTS, ORGANIC MATLS.
Hazardous Decomposition Products: NONE SPECIFIED BY MANUFACTURER.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: NOT RELEVANT.

==============================================================================
TOXICOLOGICAL
==============================================================================
N/P

==============================================================================
ECOLOGICAL
==============================================================================
N/P

==============================================================================
DISPOSAL
==============================================================================
DISPOSE I/A/W ALL APPLICABLE FEDERAL, STATE & LOCAL ENVIRONMENTAL REGULATIONS. EPA WASTE #D007 (EP TOXIC WASTE).

==============================================================================
TRANSPORTATION
==============================================================================
N/P

==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media