> Blulux Laboratories Pvt. Ltd.

CAS # CELITE 545 FILTER AID

Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad - 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300 
Fax : + 91 129 4190333
E-mail: bluluxlab@gmail.com  Website : www.blulux.com


 

HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: NO Ingestion: NO
Carcinogenicity Inds - NTP: NO IARC: YES OSHA: NO

Health Hazards Acute And Chronic: CONTAINS CRYSTALLINE SILICA WHICH IS CONSIDERED HAZARDOUS BY INHALATION. IS A KNOWN CAUSE OF SILICOSIS.

Explanation of Carcinogenicity: CONTAINS CRYSTALLINE SILICA. SEE IARC REPORT FOR DETAILS OF CARCINOGENICITY. CALIFORNIA PROP. 65 - YES

Signs and Symptoms of Overexposure: INHALATION:IRRITATION & SORENESS IN THROAT & NOSE. IN EXTREME EXPOSURE, CONGESTION MAY OCCUR. SKIN:N/A INGESTION:NOT HAZARDOUS WHEN INGESTED. EYES:TEMPORARY IRRITATION OR INFLAMMATION.

Medical Conditions Aggravated by Overexposure: PRE-EXISTING UPPER RESPIRATORY & LUNG DISEASE SUCH AS, BUT NOT LIMITED TO BRONCHITIS, EMPHYSEMA & ASTHMA.

==============================================================================
FIRST AID
==============================================================================
INHALATION:REMOVE TO FRESH AIR. DRINK WATER TO CLEAR THROAT & BLOW NOSE TO EVACUATE DUST. SKIN:N/A INGESTION:N/A EYES:FLUSH W/LARGE QUANTITIES OF WATER. IF IRRITATION PERSISTS CONSULT A PHYSICIAN.

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: NONFLAMMABLE

Auto Ignition Temperature Text: 

Lower Limits: N/A Upper Limits: N/A

Extinguishing Media: N/A

Fire Fighting Procedures: NONE

Unusal Fire/Explosion Hazard: NONE.

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: VACUUM CLEAN DDUST W/EQUIPMENT FITTED W/HEPA FILTER. USE A DUST SUPPRESSANT SUCH AS WATER IF SWEEPING IS NECESSARY.
Neutralizing Agent: MFR GAVE NO INFORMATION ON MSDS.

Waste Disposal Methods: WASTES ARE NOT HAZARDOUS AS DEFINED BY RCRA (40CFR261). DISPOSE I/A/W FEDERAL, STATE & LOCAL REGULATIONS. METHOD RECOMMENDED:LANDFILL.

==============================================================================
HANDLING AND STORAGE
==============================================================================
N/A

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: <10X PEL USE 3M 9900. <100X PEL USE MSA ULTRA TWIN H FILTER. <200X PEL USE MSA 01-00-06 W/TYPE C SUPPLIED AIR UNIT (CONTINUOUS FLOW MODE) OR EQUIVALENT.
Ventilation: USE SUFFICIENT NATURAL OR MECHANICAL VENTILATION TO KEEP DUST LEVEL BELOW PEL.
Protective Gloves: NOT NORMALLY REQUIRED.
Eye Protection: GOGGLES OR SAFETY GLASSES W/SIDE SHIELDS
Other Equipment: MFR GAVE NO INFORMATION ON MSDS.
Work Hygenic Practices: MFR GAVE NO INFORMATION ON MSDS.
Supplemental Safety & Health: NONE

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
HCC: N1
Boiling Point: 
N/A
Melting/Freezing Point: 
N/A
Decomposition Temp: 
N/K
Vapor Pressure: N/A Vapor Density: N/A
Specific Gravity: 2.3
PH: N/K
Viscosity: N/P
Evaporation Rate & Reference: N/A
Solubility in Water: NEGLIGIBLE
Appearance and Odor: FINE WHITE POWDER, NO ODOR.
Percent Volatiles by Volume: NIL
Corrosion Rate: UNKNOWN

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: NONE IN DESIGNED USE
Materials to Avoid: HYDROFLUORIC ACID.
Hazardous Decomposition Products: NONE DETERMINED
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: CANNOT OCCUR

==============================================================================
TOXICOLOGICAL
==============================================================================
N/P

==============================================================================
ECOLOGICAL
==============================================================================
N/P

==============================================================================
DISPOSAL
==============================================================================
WASTES ARE NOT HAZARDOUS AS DEFINED BY RCRA (40CFR261). DISPOSE I/A/W FEDERAL, STATE & LOCAL REGULATIONS. METHOD RECOMMENDED:LANDFILL.

==============================================================================
TRANSPORTATION
==============================================================================
N/P

==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media