CAS # 7440-70-2 CALCIUM (METAL)

Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, Industrial Area, N.I.T. Faridabad - 1, Haryana (India)
Tel. : + 91 129 4190300, 4021360, Fax : + 91 129 4190333, 4027762
E-mail: info@blulux.com, blulux@rediffmail.com Website: www.blulux.com


 

HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: N/P Skin: N/P Ingestion: N/P
Carcinogenicity Inds - NTP: N/P IARC: N/P OSHA: N/P

Health Hazards Acute And Chronic: SOLID MATERIAL WILL CAUSE SKIN AND EYE BURNS SINCE IT REACTS WITH MOISTURE TO FORM CAUSTIC. SIMILARLY, THE FUMES FROM BURNING CALCIUMARE HIGHLY IRRITATING TO SKIN, EYES, AND MUCOUS MEMBRANES.

Explanation of Carcinogenicity: N/P

Signs and Symptoms of Overexposure: SOLID MATERIAL WILL CAUSE SKIN AND EYE BURNS SINCE IT REACTS WITH MOISTURE TO FORM CAUSTIC. SIMILARLY, THE FUMES FROM BURNING CALCIUM ARE HIGHLY IRRITATING TO SKIN, EYES AND MUCOUS MEMBRANES.

Medical Conditions Aggravated by Overexposure: N/P

==============================================================================
FIRST AID
==============================================================================
SKIN: WIPE EXCESS METAL FROM SKIN. WASH WITH SOAP AND WATER. EYES: FLUSH THOROUGHLY WITH WATER FOR AT LEAST 15 MINUTES, LIFTING UPPER AND LOWER EYELIDS OCCASIONALLY. GET PROMPT MEDICAL ATTENTION. INGESTION: SPECIFIC DATA IS NOT AVAILABLE. C ALL PHYSICIAN IMMEDIATELY.

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: NON-FLAMMABLE

Auto Ignition Temperature Text: 

Lower Limits: N/A Upper Limits: N/A

Extinguishing Media: USE DRY GRAPHITE,SODA ASH,POWDERED SODIUM CHLORIDE,AND G-I POWDER.

Fire Fighting Procedures: DO NOT USE WATER OR HALOGENATED HYDROCARBONS SUCH AS CARBON TETRACHLORIDE. CARBON DIOXIDE AND DRY CHEMICALS ARE INEFFECTIVE. WEAR A SELF-CONTAINED BREATHING APPARATUS; WEAR GOGGLES. USE:SPECIAL MIXTURES OF DRY CHEMICAL OR LIME IS ONLY EXTIN GUISHING AGENTTO BE USED.

Unusal Fire/Explosion Hazard: CALCIUM REACTS WITH WATER TO FORM THE HYDROXIDE & HYDROGEN. MIXED WITH AIR, THE LIBERATED HYDROGEN MAY PRESENT AN EXPLOSION HAZARD. EXPLOSION OR VIOLENT REACTION MAY TAKE PLACE IF CARE IS NOT ECERCISED IN SELECTING EXTINGUISHANTS APPLIED TO A CALCIUM FIR.

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: WEAR PROTECTIVE EQUIPMENT AND CLOTHING. COLLECT SPILLED MATERIAL FOR RECLAMATION OR DISPOSAL IN SEALED CONTAINERS. AVOID CONTACT WITH WATER. AVOID INHALATION OF DUST.
Neutralizing Agent: N/P

Waste Disposal Methods: DISCHARGE, TREATMENT, OR DISPOSAL MAY BE SUBJECT TO FEDERAL, STATE OR LOCAL LAWS. THESE DISPOSAL GUIDE LINES ARE INTENDED FOR CATALOG-SIZE QUANTITIES ONLY. RECYCLE OR DISPOSE OF IN AN APPROVED INCINERATOR OR CONTRACT WITH A LICENSED CHEMICA L WASTE DISPOSAL SERVICE.

==============================================================================
HANDLING AND STORAGE
==============================================================================
STORE IN A COOL, DRY PLACE. NO SMOKING OR OPEN FLAMES WHEN OPENING CONTAINER. WASH THOROUGHLY AFTER HANDLING. KEEP CONTAINER CLOSED WHEN NOT IN USE.

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: NORMALLY NONE NEEDED. A NIOSH/MSHA APPROVED DUST FILTER MASK IF NEEDED.
Ventilation: LOCAL/MECHANICAL:RECOMMENDED
Protective Gloves: RUBBER.
Eye Protection: CHEMICAL SAFETY GLASSES.
Other Equipment: SAFETY GLASSES, SMOCK, APRON, EYE WASH STATION AND A FIRE EXTINGUISHER.
Work Hygenic Practices: SAFETY GLASSES, SMOCK, APRON, EYE WASH STATION AND A FIRE EXTINGUISHER.
Supplemental Safety & Health: WARD'S P/N: 37W0995. UNUSUAL FIRE AND EXPLOSION HAZARD: FINELY DIVIDED CALCIUM IS CONSIDERED PYROPHORIC AND WILL CAUSE AN EXPLOSION WHEN AN IGNITION SOURCE IS APPLIED. MODERATE EXPLOSION HAZARD IN INTIMATE CONTACT WITH VERY POWERFUL OXIDIZI NG AGENTS.

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
HCC: R2
Boiling Point: =1490.C, 2714.F

Melting/Freezing Point: =839.C, ######F

Decomposition Temp: 
N/P
Vapor Pressure: 2.0MM Vapor Density: 1.4
Specific Gravity: 1.54
PH: N/P
Viscosity: N/P
Evaporation Rate & Reference: NON-VOLATILE
Solubility in Water: VIOLENT REACTION
Appearance and Odor: SILVER-WHITE SURFACE(CUT) TO GRAY-WHITE(AIR);NO ODOR.GRANULAR,TURNING/NODULES.
Percent Volatiles by Volume: NON-VOLATILE
Corrosion Rate: N/P

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: UNSTABLE WHEN EXPOSED TO MOIST ATMOSPHERE-HEAT.
Materials to Avoid: MOISTURE FROM ANY SOURCE, ALKALI-METAL HYDROXIDES AND CARBONATES.
Hazardous Decomposition Products: CALCIUM AND WATER REACT TO PRODUCT HYDROGEN. BURNING CALCIUM IS SELF-SUSTAINING AND STRONGLY REDUCING TO ADJACENT MEDIA.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: NOT APPLICABLE.

==============================================================================
TOXICOLOGICAL
==============================================================================
NONE ESTABLISHED.

==============================================================================
ECOLOGICAL
==============================================================================
N/P

==============================================================================
DISPOSAL
==============================================================================
DISCHARGE, TREATMENT, OR DISPOSAL MAY BE SUBJECT TO FEDERAL, STATE OR LOCAL LAWS. THESE DISPOSAL GUIDE LINES ARE INTENDED FOR CATALOG-SIZE QUANTITIES ONLY. RECYCLE OR DISPOSE OF IN AN APPROVED INCINERATOR OR CONTRACT WITH A LICENSED CHEMICA L WASTE DISPOSAL SERVICE.

==============================================================================
TRANSPORTATION
==============================================================================
CALCIUM, 4.3, UN 1401, PG II.

==============================================================================
REGULATORY
==============================================================================
SARA Title III: WARNING! FLAMMABLE SOLID! A FIRE HAZARD. KEEP DRY AND WELL CLOSED. DANGEROUS WHEN WET.
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media