> Blulux Laboratories Pvt. Ltd.

CAS # CALCIUM CARBONATE PRECIPITATED AR

Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad - 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300 
Fax : + 91 129 4190333
E-mail: bluluxlab@gmail.com  Website : www.blulux.com


 

HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: YES Skin: NO Ingestion: YES
Carcinogenicity Inds - NTP: NO IARC: NO OSHA: NO

Health Hazards Acute And Chronic: INHAL:IRRITATION OF NOSE & THROAT, IRRITATION OF UPPER RESPIRATORY TRACT. SKIN:NONE IDENTIFIED. EYE:IRRITATION. INGEST:GASTROINTESTINAL PAIN. CHRONIC:NONE IDENTIFIED.

Explanation of Carcinogenicity: NOT RELEVANT.

Signs and Symptoms of Overexposure: SEE HEALTH HAZARDS.

Medical Conditions Aggravated by Overexposure: NONE IDENTIFIED.

==============================================================================
FIRST AID
==============================================================================
INGEST:IF CONSCIOUS, IMMEDIATELY GIVE LARGE AMOUNTS OF WATER. GET MD. INHAL:IF PERSON BREATHES LARGE AMOUNTS, MOVE THE EXPOSED PERSON TO FRESH AIR. SKIN:IMMEDIATELY WASH SKIN WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES. EYE:IMMEDIATELY FLU SH WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES.

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: NOT APPLICABLE

Auto Ignition Temperature Text: 

Lower Limits: N/A Upper Limits: N/A

Extinguishing Media: USE EXTINGUISHING MEDIA APPROPRIATE FOR SURROUNDING FIRE.

Fire Fighting Procedures: WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA & FULL PROTECTIVE EQUIPMENT (FP N).

Unusal Fire/Explosion Hazard: NONE IDENTIFIED.

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: WEAR SUITABLE PROTECTIVE CLOTHING. CAREFULLY SWEEP UP AND REMOVE.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.

Waste Disposal Methods: DISPOSE IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL ENVIRONMENTAL REGULATIONS.

==============================================================================
HANDLING AND STORAGE
==============================================================================
KEEP CONTAINER TIGHTLY CLOSED. SUITABLE FOR ANY GENERAL CHEMICAL STORAGE AREA.

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: NIOSH/MSHA APPROVED RESPIRATOR WITH DUST/MIST FILTER IS RECOMMENDED. IF AIRBORNE CONCENTRATION EXCEEDS TLV, A NIOSH/MSHA APPROVED SCBA IS ADVISED.
Ventilation: USE ADEQUATE GENERAL OR LOCAL EXHAUST VENTILATION TO KEEP FUME OR DUST LEVELS AS LOW AS POSSIBLE.
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: CHEMICAL WORKERS GOGGLES (FP N).
Other Equipment: LAB COAT
Work Hygenic Practices: LAB COAT
Supplemental Safety & Health: NONE SPECIFIED BY MANUFACTURER.

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
HCC: T6
Boiling Point: 
N/A
Melting/Freezing Point: 
1517F,825C
Decomposition Temp: 
N/K
Vapor Pressure: N/A Vapor Density: N/A
Specific Gravity: 2.83
PH: N/A
Viscosity: N/P
Evaporation Rate & Reference: NOT APPLICABLE
Solubility in Water: NEGLIGIBLE (<0.1%)
Appearance and Odor: SOLID GRAY GRANULES
Percent Volatiles by Volume: 0
Corrosion Rate: N/K

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: HEAT.
Materials to Avoid: STRONG ACIDS, FLUORINE, ALUM, AMMONIUM SALTS.
Hazardous Decomposition Products: OXIDES, CO, CO*2.
Hazardous Polymerization Products: NO
Conditions to Avoid Polymerization: NOT RELEVANT.

==============================================================================
TOXICOLOGICAL
==============================================================================
N/P

==============================================================================
ECOLOGICAL
==============================================================================
N/P

==============================================================================
DISPOSAL
==============================================================================
DISPOSE IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL ENVIRONMENTAL REGULATIONS.

==============================================================================
TRANSPORTATION
==============================================================================
N/P

==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media