> Blulux Laboratories Pvt. Ltd.

CAS # 513-78-0 CADMIUM CARBONATE

Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad - 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300 
Fax : + 91 129 4190333
E-mail: bluluxlab@gmail.com  Website : www.blulux.com


 

HAZARD IDENTIFICATION
==============================================================================
Route Of Entry Inds - Inhalation: N/P Skin: N/P Ingestion: N/P
Carcinogenicity Inds - NTP: YES IARC: YES OSHA: NO

Health Hazards Acute And Chronic: SEE SIGNS & SYMPTOMS OF OVEREXPOSURE.TOXIC IF INHALED OR SWALLOWED.

Explanation of Carcinogenicity: CADMIUM & CD CMPDS EVIDENCE FOR CARCIN:SUFFICIENT IN ANIMALS,LIMITED IN HUMANS (IARC 1982).CADMIUM & CERTAIN(SUPP DATA)

Signs and Symptoms of Overexposure: INHALATION:TOXIC;DUST MAY BE IRRITATING TO RESPIRATORY PASSAGES.INGESTION:TOXIC.SKIN:POSSIBLE IRRITATION OR ALLERGIC REACTION.EYES:N/K (FP N).

Medical Conditions Aggravated by Overexposure: N/K (FP N/ORNL)

==============================================================================
FIRST AID
==============================================================================
GET MEDICAL ASSISTANCE FOR ALL CASES OF OVEREXPOSURE.SKIN:WASH THOROUGHLY WITH SOAP AND WATER.EYES:FLUSH THOROUGHLY WITH WATER FOR AT LEAST 15 MINUTES.INHALATION:REMOVE TO FRESH AIR;GIVE ARTIFICIAL RESPIRATION IF NOT BREATHING.INGESTION:IF CONSCIOUS,INDUCE VOMITING.

==============================================================================
FIRE FIGHTING MEASURES
==============================================================================
Flash Point Text: NONCOMBUSTIBLE

Auto Ignition Temperature Text: 

Lower Limits: N/A Upper Limits: N/A

Extinguishing Media: ANY SUITABLE FOR ADJACENT MATERIAL.

Fire Fighting Procedures: USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE EQUIPMENT (FP N).

Unusal Fire/Explosion Hazard: THERMAL DECOMP PRODUCTS:TOXIC FUMES & DUST,CARBON DIOXIDE,CADMIUM OXIDE.

==============================================================================
RELEASE MEASURES
==============================================================================
Spill Release Procedures: TAKE UP AND CONTAINERIZE FOR PROPER DISPOSAL.
Neutralizing Agent: N/K (FP N/ORNL)

Waste Disposal Methods: DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL,STATE AND LOCAL REGULATIONS (FP N).

==============================================================================
HANDLING AND STORAGE
==============================================================================
KEEP CONTAINER CLOSED.STORE AT CONTROLLED ROOM TEMPERATURE.HANDLE OR TRANSFER ONLY IN AN APPROVED FUME HOOD OR WITH ADEQUATE VENTILATION.

==============================================================================
EXPOSURE CONTROLS/PERSONAL PROTECTION
==============================================================================
Respiratory Protection: NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN (FP N).
Ventilation: LOCAL AND GENERAL VENTILATION NECESSARY TO KEEP AIR CONCENTRATION BELOW TLV (FP N/ORNL).
Protective Gloves: YES
Eye Protection: SAFETY GLASSES WITH SIDE SHIELDS.
Other Equipment: N/K (FP N/ORNL)
Work Hygenic Practices: N/K (FP N/ORNL)
Supplemental Safety & Health: MOLECULAR WT 172.41. EXPLAN OF CARC:CADMIUM COMPOUNDS MAY REASONABLY BE ANTICIPATED TO BE A CARCINOGEN (NTP). TEST ON LAB ANIMALS INDICATE MATERIAL MAY BE CARCINOGENIC (MFR).

==============================================================================
PHYSICAL AND CHEMICAL PROPERTIES
==============================================================================
Boiling Point: 
N/A
Melting/Freezing Point: 
<932F,500C
Decomposition Temp: 
<932F,500C
Vapor Pressure: N/A Vapor Density: N/A
Specific Gravity: 4.26 (WATER=1)
PH: N/K
Viscosity: N/P
Evaporation Rate & Reference: N/A
Solubility in Water: INSOLUBLE AT 68F,20C
Appearance and Odor: WHITE POWDER
Percent Volatiles by Volume: NONE
Corrosion Rate: N/K

==============================================================================
STABILITY AND REACTIVITY
==============================================================================
Stability Indicator: YES
Stability Conditions to Avoid: HEAT.
Materials to Avoid: NONE
Hazardous Decomposition Products: TOXIC FUMES & DUST,CARBON DIOXIDE,CADMIUM OXIDE.
Hazardous Polymerization Products: N/P
Conditions to Avoid Polymerization: N/K (FP N/ORNL)

==============================================================================
TOXICOLOGICAL
==============================================================================
N/P

==============================================================================
ECOLOGICAL
==============================================================================
N/P

==============================================================================
DISPOSAL
==============================================================================
DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL,STATE AND LOCAL REGULATIONS (FP N).

==============================================================================
TRANSPORTATION
==============================================================================
N/P

==============================================================================
REGULATORY
==============================================================================
SARA Title III: N/P
Federal Regulatory: N/P
==============================================================================
OTHER
==============================================================================

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media