> Blulux Laboratories Pvt. Ltd.

CAS # 6591-52-2 Ammonium Bismuth Citrate

Blulux Laboratories Pvt. Ltd
79/66-B, I.H.I.Complex, H/W Chowk Industrial Area, N.I.T. Faridabad - 1, Haryana (India)
Tel. : + 91 129 4021360, 4190300 
Fax : + 91 129 4190333
E-mail: bluluxlab@gmail.com  Website : www.blulux.com


 

1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

Blulux Laboratories Pvt. Ltd.

79/66-B, I.H.I.Complex, Industrial Area, N.I.T. Faridabad, Haryana-121001

TEL: :++91-129-5021360, 2444433, 2237762  FAX:++ 91129-5027762

E-MAIL: blulux@rediffmail.com WEB: www.blulux.com


Product Name:
Ammonium Bismuth Citrate
Synonyms:
Bismuth Ammonium Citrate
Chemical Family:
Organic Salt
Formula:
NH4(BiOH)C6H5O7
Molecular Weight.:
433.13

2. COMPOSITION / INFORMATION ON INGREDIENTS

        Component                                 CAS #                             Appr %

____________________________________________________________
Ammonium Bismuth Citrate 6591-52-2                        100%       
____________________________________________________________

3. HAZARDS IDENTIFICATION

EMERGENCY OVERVIEW
MAY BE HARMFUL IF INHALED OR SWALLOWED.
May cause kidney damage.

Appearance:
White, odorless crystalline powder

POTENTIAL HEALTH EFFECTS (ACUTE AND CHRONIC)

Symptoms of Exposure:
May be harmful if inhaled or swallowed. Large doses can be fatal. May cause kidney damage

Medical Cond. Aggravated by Exposure:
Data not available.

Routes of Entry:
Inhalation, ingestion

Carcinogenicity:
The material is not listed (IARC, NTP, OSHA) as cancer causing agent.
____________________________________________________________
4. FIRST AID MEASURES

Emergency First Aid:
GET MEDICAL ASSISTANCE FOR ALL CASES OF OVEREXPOSURE.
Skin: Wash thoroughly with soap and water.
Eyes: Immediately flush thoroughly with water for at least 15 minutes.
Inhalation: Remove to fresh air; give artificial respiration if breathing has stopped.
Ingestion: If conscious, drink water and induce vomiting immediately as directed by medical personnel. Never give anything by mouth to an unconscious person.
____________________________________________________________
5. FIRE FIGHTING MEASURES

Flash Point (F): None
Flammable Limits LEL (%): N/A
Flammable Limits UEL (%): N/A
Extinguishing Media:
Use any suitable for adjacent material.

Fire Fighting Procedures:
Wear self-contained breathing apparatus.

Fire & Explosion Hazards:
Thermal decomposition produces toxic fumes.
____________________________________________________________
6. ACCIDENTAL RELEASE MEASURES

Spill Response:
Evacuate the area of all unnecessary personnel. Wear suitable protective equipment listed under Exposure / Personal Protection. Eliminate any ignition sources until the area is determined to be free from explosion or fire hazards. Contain the release and eliminate its source, if this can be done without risk. Take up and containerize for proper disposal as described under Disposal. Comply with Federal, State, and local regulations on reporting releases. Refer to Regulatory Information for reportable quantity and other regulatory data.
____________________________________________________________
7. HANDLING AND STORAGE

Handling & Storage:
Keep container closed. Store at controlled room temperature. Do not breathe dust. Do not get in eyes, on skin, or on clothing.
___________________________________________________________ 

8. EXPOSURE CONTROLS / PERSONAL PROTECTION

ENGINEERING CONTROLS AND PERSONAL PROTECTIVE EQUIPMENT:
Ventilation, Respiratory Protection, Protective Clothing, Eye Protection:
Respiratory Protection: If workplace exposure limit(s) of product or any component is exceeded (see TLV/PEL), a NIOSH/MSHA approved air supplied respirator is advised in absence of proper environmental control. OSHA regulations also permit other NIOSH/MSHA respirators (negative pressure type) under specified conditions (see your safety equipment supplier). Engineering and/or administrative controls should be implemented to reduce exposure. Material should be handled or transferred in an approved fume hood or with adequate ventilation. Protective gloves should be worn to prevent skin contact (Neoprene or equivalent) Safety glasses with side shields should be worn at all times.

Work/Hygienic Practices:
Wash thoroughly after handling. Do not take internally. Eyewash and safety equipment should be readily available.

EXPOSURE GUIDELINES

OSHA - PEL:

                TWA           STEL             CL
Component   PPM    MG/M3   PPM    MG/M3   PPM    MG/M3  Skin
____________________________________________________________
Ammonium Bismuth Citrate                   

ACGIH - TLV:

                TWA           STEL             CL
Component   PPM    MG/M3   PPM    MG/M3   PPM    MG/M3  Skin
____________________________________________________________
Ammonium Bismuth Citrate
If there are no exposure limit numbers listed in the Exposure Guidelines chart, this indicates that no OSHA or ACGIH exposure limts have been established.
____________________________________________________________








 
9. PHYSICAL AND CHEMCIAL PROPERTIES

Boiling Point (C 760 mmHg) : N/A
Melting Point (C) : N/A
Specific Gravity (H20 = 1) : N/A
Vapor Pressure (mm Hg) : N/A
Percent Volatile by vol (%): N/A
Vapor Density (Air = 1) : N/A
Evaporation Rate (BuAc = 1): N/A
Solubility in Water (%) : 35%
Appearance :
White, odorless crystalline powder

____________________________________________________________ 

10. STABILITY AND REACTIVITY

Stability: Yes

Hazardous Polymerization:
Does not occur

Hazardous Decomposition:
NH3, NOx, Bismuth Compounds, COx

Conditions to Avoid:
Dusting; extreme heat.

Materials To Avoid:

     ( ) Water
     ( ) Acids
     ( ) Bases
     ( ) Corrosives
     ( ) Oxidizers
     (X) Other: None indicated
____________________________________________________________


11. TOXICOLOGICAL INFORMATION

Toxicity Data

None established.                

Toxicological Findings:
None
Cited in Registry of Toxic Effects of Chemical Substances (RTECS)

____________________________________________________________

12. DISPOSAL CONSIDERATIONS

EPA Waste Numbers:        


Treatment:
Material does not have an EPA Waste number and is not a listed waste, however consultation with a  permitted waste disposal site (TSD) should be accomplished.
ALWAYS CONTACT A PERMITTED WASTE DISPOSER (TSD) TO ASSURE COMPLIANCE WITH ALL CURRENT LOCAL, STATE AND FEDERAL REGULATIONS.

____________________________________________________________

13. TRANSPORT INFORMATION

DOT Proper Shipping Name:
non-regulated

DOT ID Number :
none

____________________________________________________________

 
14. REGULATORY INFORMATION


For Research and Development Use Only; Not for Manufacturing or Commercial Purposes

                                                             SARA            SARA         CERCLA
 Component                                        EHS            EHS TPQ         RQ
                                                             (302)            (lbs)        (lbs)
____________________________________________________________
Ammonium Bismuth Citrate
                                                            
                                         OSHA            SARA        DeMinimis
 Component                   Floor List         313        for SARA 313
                                                                                           (%)
____________________________________________________________

Section 15 Preparation Information
________________________________________________________________________________________
Prepared by: BLULUX LABORATORIES (P) LTD.

For questions contact: Blulux Laboratories Pvt. Ltd.

79/66-B, I.H.I.Complex, Industrial Area, N.I.T. Faridabad, Haryana-121001

TEL: :++91-129-5021360, 2444433, 2237762  FAX:++ 91129-5027762 E-MAIL: blulux@rediffmail.com

The statements contained herein are offered for informational purposes only and are based upon technical data that Blulux Laboratories Pvt. Ltd.  believes to be accurate. It is intended for use only by persons having the necessary technical skills and at their own discretion and risk. Since conditions and manner of use are outside our control, we make NO WARRANTY, EXPRESS OR IMPLIED, OF MERCHANTABILITY, FITNESS OR OTHERWISE.

 

Mfgs. & Exporters: Laboratory Reagents, Fine Chemicals, Analytical Reagents & Dehydrated Culture Media